7.2.2 Spigot IR (code 20)
L c Ød H1 H s MG DN Connection types code 20 1) Material code 2) 20 71 75 NPS L H H1 ød c s s s 20 15 1/2" 154.0 36.0 10.0 20.0 33.0 - 1.9 1.9 20 3/4" 154.0 38.0 12.0 25.0 33.0 - 2.3 1.9 25 1" 154.0 39.0 13.0 32.0 33.0 - 2.9 2.4 25 32 1¼" 194.0 41.0 15.0 40.0 33.0 - 3.7 2.4 40 40 1½" 194.0 63.2 23.2 50.0 33.0 - 4.6 3.0 50 ...
7.2.11 Flange ANSI Class (code 39)
GEM eSyDrive R649 H1 H FTF ØD Øk Ød ØL MG DN Connection types code 39 1) Material code 2) 1 5, 20 71, 75 1 5, 20 71, 75 1 5, 20 71, 75 1 5, 20 71, 75 FTF H H1 øD øL ød øk 20 15 130.0 36.0 10.0 95.0 - 95.0 16.0 - 16.0 45.0 - 45.0 60.0 - 60.0 20 20 150.0 38.0 12.0 105.0 - 105.0 16.0 - 16.0 54.0 - 54.0 70.0 - 70.0 25 160.0 39.0 1 ...
30 / 41
GEM eSyDrive R649 GEMÜ R649 9 Installation in piping 9.6 Installation with threaded spigots Fig. 7: Threaded spigots NOTICE Thread sealant ▶ The thread sealant is not included in the scope of deliv- ery. ● Only use appropriate thread sealant. 1. Keep thread sealant ready. 2. Carry out preparations for installation (see chapter "Pre- parations ...
7.2.4 Union end DIN (code 7 / MG 20- 40)
GEM eSyDrive R649 L1 H1 H L2 R ØD Ød MG DN Connection types code 7 1) Material code 2) 1 4 71 75 R NPS øD L1 H H1 ød L2 L2 L2 L2 20 15 G 1 1/2" 43.0 108.0 36.0 10.0 20.0 146.0 150.0 143.0 146.0 20 G 1¼ 3/4" 53.0 108.0 38.0 12.0 25.0 152.0 156.0 146.0 150.0 25 G 1½ 1" 60.0 116.0 39.0 13.0 32.0 166.0 170.0 158.0 162.0 25 32 ...
29 / 41
GEM eSyDrive R649 GEMÜ R649 CAUTION Use as step. ▶ Damage to the product. ▶ Risk of slipping-off. ● Choose the installation location so that the product can- not be used as a foothold. ● Do not use the product as a step or a foothold. NOTICE Suitability of the product! ▶ The product must be appropriate for the piping system operating con ...
19 Declaration of Incorporation according to 2006/42/EC (Machinery Directive)
GEM eSyDrive R649 Declaration of Incorporation according to the EC Machinery Directive 2006/42/EC, Annex II, 1.B for partly completed machinery We, GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG Fritz-Müller-Straße 6-8 74653 Ingelfingen-Criesbach, Germany declare that the following product Make: GE ...
6 / 41
GEMÜ R649 3 Product description 3.2 Buttons for on-site control 8 9 10 Fig. 1: Position of the buttons Item Name Function 8 DIP switch, "ON- site" control Switches the on-site control on the device on or off 9 "OPEN" button Moves actuator to the open position Resets the network settings 10 "INIT/CLOSE" button Moves actuator to the ...
6.5 Mechanical data
GEM eSyDrive R649 Protection class: IP 65 acc. to EN 60529 Weight: Actuator - 9.5 kg Body Valve body MG 10 DN 12 DN 15 DN 20 Threaded socket code 1 0.08 - - Solvent cement socket code 2 0.06 - - Union end code 7 - 0.18 - Union end code 33 - 0.13 - Union end code ...
Pressure/temperature correlation PN 6
Valve body material Temperature in °C (valve body) Materi- als Code -20 -10 ±0 5 10 20 25 30 40 50 60 70 80 PVC-U 1 - - - - 6.0 6.0 6.0 4.8 3.6 2.1 0.9 - - ABS 4 6.0 6.0 6.0 6.0 6.0 6.0 6.0 4.8 3.6 2.4 1.2 - - PP 5 - - - 6.0 6.0 6.0 6.0 6.0 6.0 5.5 4.0 2.7 1.5 PP-H 71 - - - 6.0 6.0 6.0 ...
7.3 Valve body mounting
GEM eSyDrive R649 M5 35 / 1.38 M10 60 120 M f Diaphragm size 10 Diaphragm size 20 - 100 DN 15 - 80 DN 100 MG DN M f 10 12 - 20 M5 35.0 20 15 – 25 M6 25.0 25 32 M6 25.0 40 40 – 50 M8 44.5 50 65 M8 44.5 80 80 M12 100.0 100 100 see drawing Dimensions in mm, MG = diaphragm size For valve body material ABS (code 4) and connection type inch (code 30) the ...
33 / 41
GEM eSyDrive R649 GEMÜ R649 3 4. Place the actuator of housing cover 12 in the starting point for manual override. 3 12 Item Name 3 Housing cover 12 Housing cover actuator Starting point for manual override Groove for actuator 5. Turn housing cover 3 anticlockwise. ð The product opens. 6. Turn housing cover 3 clockwise. ð The product closes. 7. P ...
GEM eSyDrive R649 user guide recommended for: 411, R478 Tugela, 52, R563, 567 servoDrive.
⚠️ Download Safety
The Control Unit Operating instructions manual (41 pages) is completely safe to download (last scan date: 08/03/2026).
Control Unit: Frequently Requested PDF Instructions
-
Neoway N77 Wireless modules Hardware user's manual
64 -
ESBE VTR300 Series Control Unit Manual
8 -
Altech B 2070-2 Control Unit Installation manual
12 -
Zennio MINiBOX 0-10V X3 Controller Operation & user’s manual
19 -
Toshiba AJ65VBTCU-68ADVN Control Unit Operation & user’s manual
106 -