Electric Heat Exchanger

Electric/Swimming Pool Water EWT 95 - 15 Your BEHNCKE® Specialist Dealer – Subject to technical alteration! – Stand 03/2011 ...

Version of March 2011

Dear costomer, congratulations on purchasing your new, state-of-the-art electric heat exchanger „Made in Germany“. Behncke® GmbH has produced high-quality pro- ducts for the public and private swimming pool and whirlpool sector for more than 30 years. Your Behncke® specialist dealer will always give you advice and support. Please ...

Table of contents

1 Safety 28 1.1 Risks When Handling Electric Heat Exchanger 28 1.2 Safety Instructions and Information 28 1.3 Intended Use 29 1.4 Sources of Danger 30 1.5 Safety Measures on the Installation Site 30 1.6 Safety Equipment 30 2 Technical Data 31 2.1 EWT 95 - 15 31 3 Set-up/Installation 32 3.1 Transportation/Storage 32 3.2 ...

Risks When Handling Electric Heat Exchanger

The electric heat exchanger has been built on the basis of state-of-the-art techno- logy and the approved safety-technical guidelines. Nevertheless, risk might occur during use such as - violation of operator or - third parties - impairments in electric heat exchanger or - damage to other mat ...

The electric heat exchanger is exclusively designed for heating bathwater with acti-

vated recirculating or filter pump. Any other mode of application is not regarded as intended use. The manufacturer Behncke ® GmbH is not liable for any resulting damage. Other uses are only possible upon agreement with and approval by the manufac ...

Sources of Danger

The electric heat exchanger can be damaged. If the maximum operational pressure of 3.0 bar is exceeded, the electric heat exchanger might develop leaks. The risk of burns exist. The connections and the electric heat exchanger might reach temperatures of up to 100°C. In the case of insufficient throughput (<5000 l/h) strong ov ...

EWT 95 - 15

Article Power in KW Supply Temperature Article No. Voltage Selection in Volt in °C EWT 95 -15 18 230/400 – 302 051 18 EWT 95 -15 27 230/400 – 302 051 27 EWT 95 -15 36 230/400 – 302 051 36 EWT 95 -15 45 230/400 – 302 051 45 ...

Transport the electric heat exchanger only after it has been drained.

Store the flushed and drained electric heat exchanger in interior rooms with non-aggressive atmosphere only. 3.2 Set-up and Installation Dimensions Article KW A B C mm mm Kombi Socket EWT 95 -15 18 560 275 d50/11/2” ...

Set up the electric heat exchanger in frost-proof and dry rooms with non-agressive

atmosphere only. Dripping water might damage the electric heat exchanger. Ensure easy access for installation and removal purposes. The following water values are to be observed for the electric heat exchanger. EWT 60-20/30 Chloride contents m ...

Installation Layout Above the Water Level

Figure: horizontal installation Figure: horizontal installation 3.5.2 Installation Layout Below the Water Level ...