Solahart AtmosAir 180 Operation & Installation Manual

File Specifications

Brand: Solahart
Category: Heat Pump
Model: AtmosAir 180 (Operation & Installation Manual), prFkIqcbjExtY
File Info: Adobe Acrobat PDF (DjVu)
File Size: —
Pages: 36 pages

Download PDF

Download Solahart AtmosAir 180 Manual (36 pages)

Read Online:

Read the Solahart AtmosAir 180 Operation & Installation Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

1 Alan Street, Rydalmere

New South Wales 2116 Australia Telephone International Sales: + 61 2 9684 9100 Facsimile International Sales: + 61 2 9684 9180 Email: [email protected] Web: www.solahart.com ...

Outlet water temperature

Solahart AtmosAir 180 Time ON 1 Press and hold for 2s. OFF 1 Press " " and hold for 2s to enter into the next setting without confirm the previous one. ON 2 Press " " and hold for 2s to enter into the next setting without confirm the previous one. Press " " and hold for 2s to enter into ...

Refrigerant is compressed into vapor with high temperature and high pressure when

Solahart AtmosAir 180 it goes through the compressor. On the discharge side of the compressor, the now hot and highly pressurized vapor is cooled d ...

3 minutes protection

Solahart AtmosAir 180 If the unit stops and you re start the unit or turn it on by the manual switch, the unit will not start to run again for approx 3 minutes. This is a protection feature to safe guard the compressor. In low ambient conditions the heating output decreases. Heating capacity Working conditions Defrosting In the heating ...

5.2.3 Target temperature checking and setting

In the standby or running interface, press " " or " " once to check the target temperature of the outlet water. Press " " or " " again to change the target temperature. After making the changes to the parameter, press " " to confirm or " " to cancel the changes, then r ...

Fixing the unit

Solahart AtmosAir 180 Circuit breaker required The unit CANNOT be installed near flammable gas. Ensure that the base you are fixing to is level and strong enough. This unit requires a circuit breaker. failure to do so could result in an electrical shock or fire. OPERATION WARNING Prohibited Shut off the power Do not ...

MODEL: ATMOS AIR 180

16.5 1944.5 1277 Cold water inlet Hot water outlet Condensation water outlet Magnesium Over heating protector Electric heater Drainpipe 99 1177 1464.5 Pressure release valve 540 ...

7.2 The method of grounding

Solahart AtmosAir 180 7.3 of the Pressure release valve Use Pressure release valve is used to pressure going too high inside the tank. When the pressure reaches the set value, the valve will open automatically so as to decrease the pressure . The handle of the safety valve should be pulled once every six months so as to remove th ...

4.4 Cable connection

Solahart AtmosAir 180 4.5 Trial running This unit requires an isolating switch as required by local by laws. 4.5.1 Inspection before trial running Check the water supply to the tank and pipe connections for possible leaks. Check that all power connections are secure before switching on. 4.5.2 Trial running Switch on the unit using the cont ...

6.Maintenance and repair

Solahart AtmosAir 180 Check the water supply and air vent frequently, to avoid lack of water or air in the water loop. Clean the water filter Lack of water and dirty water can damage the unit. The heat pump will start the water pump per when it is not running, to avoid freezing. periodically, helping the water to stay clean. every 72 hrs Keep the uni ...

Solahart AtmosAir 180 user guide recommended for: WP90, S1 7KS, RP13, ATMOS AIR 270, Tranquility TR Series.

⚠️ Download Safety

The Heat Pump Operation & installation manual (36 pages) is completely safe to download (last scan date: 08/07/2026).

Heat Pump: Frequently Requested PDF Instructions