Key Pages of Document

These kits are for use with Raychem IceStop, XL-Trace and HWAT heating

cables. The connection is designed to be strapped to the pipe or mounted on the wall at the start of the heating cable circuit. These installation instructions should be used in conjunction with the IceStop, XL-Trace and HWAT System Installation and Operation Manuals ...

RayClic-PC, RayClic-PS, RayClic-PT Installation Instructions

5 4 • Score around and down the outer jacket of the heating cable 3 1/8 inches from the end. • Remove the outer jacket. • Place the metal clip over the base of the exposed braid. Do not cut through metal braid or inner jacket. 1 2A 3 2B • Using the plastic cable ties, attach* the bracket ...

RayClic-PC, RayClic-PS, RayClic-PT Installation Instructions

6B 6A • Pull exposed braid back over metal clip. 8 • Insert prepared heating cable end into connector. Push until heating cable is fully inserted and end is visible through opening in connection cover plate. HWAT Only IceStop and XL-Trace Only 3 1/8" 1" 9 • For HWAT only: Apply HWAT label o ...

• Using glass cloth tape,

attach heating cable to pipe. • Apply insulation, cladding and warning labels. • Terminate power wiring in user-supplied junction box. • Using glass cloth tape, attach heating cable to pipe. • Apply insulation, cladding and warning labels. • Terminate power wiring i ...

• Attach the connector to the mounting bracket

by pressing until it snaps in place. • Complete heating cable installation and install a drip loop as shown. • Protect heating cable from sharp edges. Power Connection • Connect user-supplied 1/2-inch conduit by following step 11 on page 4. • Apply Electric De-Icing and Snow ...

RayClic-PC, RayClic-PS, RayClic-PT Installation Instructions

1" 2 1 • Remove exposed braid. • Push end seal completely onto heating cable. End Seal Installation 3 1/8" 1" IceStop and XL Trace HWAT IceStop and XL-Trace HWAT H W A T IceStop and XL-Trace Note: The end seal is designed to be installed only once; it cannot be removed from the heating cabl ...

RayClic-PC, RayClic-PS, RayClic-PT Installation Instructions

Troubleshooting Guide Problem Solution Braid�clips�are�missing. The braid clips are attached to the cardboard packing insert under the lid. The braid clips must be used to ensure a ground connection. If clips are missing or lost, call Tyco Thermal Controls at (800) 545-6258. Mounting brac ...

RayClic-PC, RayClic-PS, RayClic-PT Installation Instructions

© 2011 Tyco Thermal Controls LLC INST-172 PN 511491-000 H55092 05/11 Tyco, HWAT, IceStop, RayClic, and XL-Trace are registered and/or unregistered trademarks of Tyco Thermal Controls LLC or its affiliates. TORX is a registered trademark of Textron., Inc. Worldwide Headquarters T ...