Absolute Process Instruments DuoPak APD 2006 Manuals
1 pdf manual(s) Absolute Process Instruments DuoPak APD 2006 for free download (Document Types: Manual )
Absolute Process Instruments DuoPak APD 2006 Manual [PDF] (2 pages)
- Identifier: id-1913149
- Brand: Absolute Process Instruments
- Device: DuoPak APD 2006 Media Converter
- Type: PDF
- Key Aspects: Basic Configuration Guidelines, Glossary of Technical Terms, Critical Operational Precautions
- UPD Date: 18.08.2026
- Source File: 1809611.pdf
- Pages: 2
- Description: Product instruction manual for the Absolute Process Instruments DuoPak APD 2006.
Click to expand and read text
® Two Channel Signal Converter/Isolator/Transmitter APD 2006 api-usa.com 1220 American Way Libertyville, IL 60048 Phone: 800-942-0315 Fax: 800-949-7502 BSOLUTE ROCESS NSTRUMENTS, Inc. © 06-14 O Two Independent Channels with Full Isolation O Zero and Span for Each Output O Input and Output LoopTracker ® LEDs O Output Test/Manual Override for Each Channel O Built-In I/O Power Supplies Q Monitor a DC Signal and an AC Signal Q Convert/Isolate Dual Output Transmitters Applications Removable Plugs Quick Link api-usa.com/2000 Dimensions 1.78" W x 4.62" H x 4.81" D 45 mm W x 117 mm H x 122 mm D Height includes connectors Sink or Source mA Output for Each Channel Output LoopTracker LED for Each Channel Adjustable Output Test Function for Each Channel Zero and Span for Each Channel Custom I/O Ranges Description The APD 2006 DuoPak accepts one DC voltage or current input and one AC voltage or current input provides two optically isolated DC voltage or current outputs that are linearly related to the inputs. The input ranges and the output ranges for each channel are independent and can be specified as required. This provides an economical two channel solution in one device. Typical applications include signal conversion, isolation, and redundancy (i.e. to prevent failure of the entire loop if one device fails), or a combination of these. Each input signal is filtered, amplified, and then passed through an opto-coupler to the output stages. Full 5-way isolation (input 1, input 2, output 1, output 2, power) make this module useful for ground loop elimination, common mode signal rejection, and noise pickup reduction. I/O Sink/Source Versatility Standard on the APD 2006 is a 15 VDC loop excitation supply for the DC input channel and 20 VDC loop excitation sup- plies for each output channel. These power supplies can be selectively wired for sinking or sourcing allowing use with any combination of powered or unpowered milliamp I/O devices. LoopTracker API exclusive features include four LoopTracker LEDs (green for each input, red for each output) that vary in intensity with changes in the process input and output signals. These provide a quick visual picture of your process loop at all times and can greatly aid in saving time during initial startup and troubleshooting. Output Test An API exclusive feature includes output test buttons for each channel to provide a fixed output (independent of the input) when held depressed. Terminals are also provided to operate the test functions remotely for each channel. This also allows use as a remote manual override to provide a temporary fixed output if desired. The test output level for each channel is potentiometer adjust- able from 0 to 100% of the output span. The output test greatly aids in saving time during initial startup and/or troubleshooting. Universal Power Input LoopTracker LED for Each Channel Free Factory I/O Setup! Channel 1: DC to DC Channel 2: AC to DC Channel 1 DC Input Range Factory configured, please specify input type and range Voltage: 0-10 mVDC to 0-100 VDC Bipolar voltage: ±50 mVDC to ±10 VDC Current: 0-1 mADC to 0-50 mADC, 4-20 mADC Voltage input impedance: 200 kΩ minimum Current input impedance: 50 Ω typical Input com. mode rejection: 120 dB minimum Current input voltage burden: 1.25 VDC max. at 20 mA Input loop power supply: 15 VDC, ±10%, regulated, 25 mADC, may be connected for sinking or sourcing mA input Channel 2 AC Input Range Factory configured, please specify input type and range Voltage: 0-50 mVAC to 0-300 VAC Current: 0-1 mAAC to 0-1000 mAAC Measurement type: True RMS Frequency: 40 Hz to 1000 Hz sinusoidal Voltage input impedance: 220 kΩ minimum Current input voltage burden: 1.0 VRMS maximum LoopTracker Variable brightness LEDs indicate I/O levels for each channel Channel 1 and Channel 2 Output Ranges Factory configured, please specify for each output channel Voltage: 0-1 VDC to 0-10 VDC, 10 mA max up to 20 VDC with M19, M29, M39 Bipolar voltage: ±1 VDC to ±10 VDC Current: 0-1 mADC to 0-25 mADC, 4-20 mADC 20 V compliance, 1000 Ω at 20 mA Output Loop Power Supplies 20 VDC nominal, regulated, 25 mADC for each output channel May be selectively wired for sinking or sourcing mA output Output Calibration Multi-turn zero and span potentiometers for each output channel ±15% of span adjustment range typical Characteristics Accuracy: ±0.1% of span (incl. adj. resolution and linearity) Output ripple and noise: Less than 10 mVRMS Isolation: Full 5-way, 1200 VRMS minimum Response Time 70 milliseconds typical Ambient Temperature Range and Stability –10°C to +60°C operating ambient, <±0.04% span/°C stability Output Loop Power Supplies 20 VDC nominal, regulated, 25 mADC for each output channel May be selectively wired for sinking or sourcing mA output Output Test Front buttons set each output to test level when pressed Each test level potentiometer adjustable 0-100% of span Housing and Connectors IP 40, requires installation in panel or enclosure Mounts to standard 35 mm DIN rail Eight 4-terminal removable connectors, 14 AWG max wire size Power 85-265 VAC, 50/60 Hz or 60-300 VDC, 6 W maximum D versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 6 W maximum Connect Sink or Source mA for DC Input Options—add to end of model number R1 Channel 1 I/O reversal (i.e. 20-4 mA out) R2 Channel 2 I/O reversal (i.e. 20-4 mA out) R3 Channel 1 and channel 2 I/O reversal M19 Channel 1 high voltage output >10 V up to 20 V M29 Channel 2 high voltage output >10 V up to 20 V M39 Channel 1 and channel 2 high voltage output U Conformal coating for moisture resistance Accessory—order as separate line item API BP4 Spare removable 4 terminal plug, black How to Order Models are factory ranged. See I/O ranges above left. Ranges and options for each channel must be specified on order Channel 1 input range Channel 2 input range Channel 1 output range Channel 2 output range Model Description Power APD 2006 DuoPak 2 channel DC-DC, AC-DC converter/isolator/ transmitter 85-265 VAC, 50/60 Hz or 60-300 VDC APD 2006 D 9-30 VDC or 10-32 VAC Options and Accessories H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H Made in USA
DuoPak APD 2006: Related Instructions
RTD Input Alarm Trips, Factory Ranged, Isolated APD 1400, APD 1420 Input: 2 or 3 Wire RTD Output: Two 8 Amp SPDT Relays O Factory Set Input Range O Removable Pl User guide for the Absolute Process Instruments APD 1400 Security System. The document presents hardware components, service instructions, installation steps, replacement parts.
AC to DC Transmitters, Isolated, Field Rangeable API 6380 G Series Input: 0-50 mVAC to 0-250 VAC, 0-5 mAAC to 0-200 mAAC Output: 0-1 VDC to ±10 VDC, 0-2 mADC t Official installation manual for the Absolute Process Instruments API 6380 G Series Transmitter. This guide presents instructions on product maintenance, device features, network configuration, configuration options.
DC to Frequency Transmitters, Isolated, Field Rangeable API 7500 G, API 7500 G SS Input: 0-50 mV to ±10 VDC, 0-1 mA to 4-20 mA Output: 0-1 Hz to 0-30 kHz MOSFE Product operation guide for the Absolute Process Instruments API 7500 G Transmitter. It explains configuration options and technical overview, operation, product safety.
api-usa.com 1220 American Way Libertyville, IL 60048 Phone: 800-942-0315 Fax: 800-949-7502 BSOLUTE ROCESS NSTRUMENTS, Inc. © 06-14 O Two Independent Channels w Device operation guide for the Absolute Process Instruments DuoPak APD 2011 Media Converter. The document details configuration and usage procedures, component replacement, error codes, replacement parts.
AC Input Alarm Trips, Factory Ranged API 1600 G, API 1620 G Input: 0-50 mVAC to 0-300 VAC, 0-1 mAAC to 0-900 mAAC Output: One 8 Amp DPDT Relay or Two 8 Amp SPDT Product instruction handbook for the Absolute Process Instruments API 1600 G Transmitter. This guide provides information on performance optimization, backup procedures, calibration steps.
api-usa.com 1220 American Way Libertyville, IL 60048 Phone: 800-942-0315 Fax: 800-949-7502 BSOLUTE ROCESS NSTRUMENTS, Inc. © 06-14 O Two Independent Channels w Official user manual for the Absolute Process Instruments DuoPak APD 2003 Media Converter. This manual provides information on safety protocols, operation, setup instructions.
Similar Manuals in the Media Converter Category
1/9 © 2022 ROHM Co., Ltd. No. 64UG043E Rev.001 2022.2 User’s Guide Switching Regulator Series Buck Converter with Integrated FET BD9E304FP4-LBZ EVK BD9E304FP Product instruction manual for the Rohm BD9E304FP4-LBZ EVK Media Converter. The manual provides technical details on firmware installation, maintenance guidelines, performance optimization, safety precautions.
P/N: 2900-301296 Rev 1 www.kramerAV.com USER MANUAL MODEL: VP-551X 4K Presentation Matrix Switcher Scaler DRAFT User operation guide for the Kramer VP-551X Media Converter. The document elaborates on device functions and usage examples, system configuration, daily usage, maintenance schedule.
The Drive & Control Company Rexroth IndraControl S67 sercos Coupler 8 Digital Inputs (M8) Edition 03 Application Description R911338401 Complete usage guide for the Bosch Rexroth IndraControl S67-S3-BK-DI8-M8 Network Hardware. It outlines the setup and replacement parts, device overview, system setup, power requirements.
CONV1-G rev 2.0 Ewimar Sp. z o.o. www.ewimar.pl The converter is a microprocessor device which converts Pelco-D protocol to Pelco-P or Pelco-P protocol to Pelco Detailed operating instructions for the Ewimar CONV1-G 2 Media Converter. It describes maintenance tasks and product maintenance, system parameters, setup tips.