Kusam-meco KM 877 Manuals

1 pdf manual(s) Kusam-meco KM 877 for free download (Document Types: Operating manual)

Kusam-meco KM 877 Operating manual Thumbnail

Kusam-meco KM 877 Operating manual [PDF] (19 pages)

  • Identifier: id-813702
  • Brand: Kusam-meco
  • Device: Kusam-meco KM 877 Multimeter
  • Type: Operating manual, PDF
  • Key Aspects: Additional Modules and Accessories Guide, Device Specifications Overview, Warranty and Service Information
  • UPD Date: 19.08.2026
  • Source File: 826062.pdf
  • Pages: 19
  • Description: Operation and maintenance manual for the Kusam-meco KM 877.
Pages Preview:
  • Kusam-meco KM 877 Operating manual preview - page 2
  • Kusam-meco KM 877 Operating manual preview - page 3
  • Kusam-meco KM 877 Operating manual preview - page 4
  • Kusam-meco KM 877 Operating manual preview - page 5
  • Kusam-meco KM 877 Operating manual preview - page 6
  • Kusam-meco KM 877 Operating manual preview - page 7
  • Kusam-meco KM 877 Operating manual preview - page 8
  • Kusam-meco KM 877 Operating manual preview - page 9
Document Preview & Text Transcription (Main Page)
Click to expand and read text
� � Paper-White � � � Dual Digital � PI & DAR Function. � VFD V & Hz readings. Record MAX / MIN readings. Display Hold Function. Display. Autoranging. Backlight LCD Display GENERAL SPECIFICATIONS : � � � � � � � � � � � � � � � � � � � � � Sensing : AC, True RMS Display : 3-5/6 digits 6000 Counts Backlight LCD Display. 61 Segments Analog Bar Graph : 60 per second max. I Auto or Manual-ranging mode. Auto Power Off. Polarity : Automatic Update Rate : 5 per second nominal Power Supply: Four Alkaline AA batteries +Hz +Hz Power Consumption: 4.5mA typical except : ACV & VFD ACV : 7.0mA Earth Continuity Test : 110mA @20� range, 220mA @2.0� range. Tester can perform at least 3000 Earth Continuity Test measurements with new alkaline batteries at room temperature. These are standard test of 1� with a duty cycle of 5 seconds on & 25 seconds off. Insulation Resistance @ 1mA Test Current : 50V output Voltage : 25mA, 100V output Voltage : 45mA 250V output Voltage : 85mA, 500V output Voltage : 170mA 1000V output Voltage : 440mA Tester can perform at least 950 Insulation Tests with new alkaline batteries at room temperature. These are standard tests of 1000V into 1M� with a duty cycle of 5 seconds on and 25 seconds off. Operating Temperature : -10ºC ~ 40ºC Relative Humidity : Maximum relative humidity 90% for temperature up to 28ºC decreasing linearly to 50% relative humidity at 40ºC. Pollution degree : 2 P Rating : IP40 Storage Temperature : -20ºC ~ 60ºC, < 80% R.H. (with battery removed) Altitude : Operating below 2000m Temperature Coefficient : Nominal 0.15 x (specified accuracy)/ °C @(-10ºC~18ºC or 28ºC~40ºC), or otherwise specified. Low Battery: approx. 4.6V APO Timing: Idle for 20 minutes APO Consumption: 50� A typical Dimension: 208(L) X 103(W) X 64.5(H) mm with holster Weight: 635 gm with holster. TRUE RMS DIGITAL INSULATION MULTIMETER MODEL KM 877 Preliminary Data D:/Chhaya/My Documents/Chhaya/backup/catlogs/NEW CAT/2013-2014/KM 877.cdr An ISO 9001:2008 Company ®® SPECIAL FEATURES : All Specifications are subject to change without prior notice � Pass /Fail Insulation Resistance Compare function; 12 selectable Preset Values. � � � LOCK-Test mode for Insulation Resistance & Earth Continuity Test. BeepJack audible & visible input warning. Remote Probe for insulation Resistance & Earth Continuity Test. TM SAFETY : � � � � � Safety : Double insulation per IEC/UL/EN61010-1 Ed. 3.0, IEC/EN61010-2-030 Ed. 1.0, IEC/EN61010-2-033 Ed. 1.0, IEC/UL/EN61010-031 Ed. 1.1 and CAN/CSA-C22.2 No. 61010-1-12 Ed. 3.0 to CAT III 1000 V AC & DC and CAT IV 600V AC & DC. Compliance to IEC/EN61557; 2007 (per CE requirements, not certified by UL or ETL) : IEC/EN61557-1, IEC/EN61557-2 & IEC/EN61557-4 where applicable. E.M.C. : Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11) In an RF field of 3V/m: Total Accuracy = Specified Accuracy + 25 digits. Performance above 3V/m is not specified. Overload Protections : Earth Continuity Test : 0.25A/1KV, IR 30kA or better V : 1100Vrms mV, � & Others : 1000 Vrms Transient Protection : 8KV(1.2/50� S Surge) ACCESSORIES : ACCESSORIES : Test probe pair, BRP21S2-C Remote probe, Alligator clip pair, Holster, User manual & Carrying Case. OPTIONAL Magnetic hanger. NEW 23 Functions 73 Ranges

Similar Manuals in the Multimeter Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Circutor CPM M80430

CPM M80430 Instruction manual - 371C2M

20 249 58 01-07-2026 view all manuals
Hanna Instruments PICCOLO 2 HI 98112

Hanna Instruments Multimeter Instruction manual (File: PDF, 08-07-2026)

2 0.13 Mb 584 117 08-07-2026 view all manuals
Amprobe AM-560

AM-560 Operation & user’s manual - Q99V94

89 340 65 18-06-2026 view all manuals
GW Instek GDM-452

GDM-452 Operating manual - U7QAD2

3 1117 168 13-03-2026 view all manuals
Tektronix DMM4040

Multimeter #L5DKK4

112 2.33 Mb 701 134 27-05-2026 view all manuals
Conrad VC 350E

#6F89T7: VC 350E Multimeter Operating instructions manual

91 25 7 26-08-2026 view all manuals