LUX PSPH521 SERIES Manuals
2 pdf manual(s) LUX PSPH521 SERIES for free download (Document Types: Installation and operating instructions)
LUX PSPH521 SERIES Installation and operating instructions [PDF] (4 pages)
- Identifier: id-1006813
- Brand: LUX
- Device: LUX PSPH521 SERIES Thermostat
- Type: Installation and operating instructions, PDF
- Key Aspects: Cleaning and Sanitization Methods, FAQ Section for Common Queries, Environmental Factors and Restrictions
- UPD Date: 08.03.2026
- Source File: 1151672.pdf
- Pages: 4
- Description: Quick start guide for the LUX PSPH521 SERIES.
Pages Preview:
LUX PSPH521 SERIES Installation and operating instructions [PDF] (3 pages)
- Identifier: id-985171
- Brand: LUX
- Device: LUX PSPH521 SERIES Thermostat
- Type: Installation and operating instructions, PDF
- Key Aspects: Operational Mode Explanations, Detailed Installation Instructions, Model Variations and Compatibility
- UPD Date: 21.08.2026
- Source File: 1173325.pdf
- Pages: 3
- Description: User operation guide for the LUX PSPH521 SERIES.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 © COPYRIGHT 2004 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED • The Unit can be used with most two stage heat and one stage cool heat pump systems. It cannot be used with 120 volt heating systems. Ask your dealer for other LUX thermostats to control those systems. • The Unit is programmable. There are four programming periods per day. Each period can be programmed separately. • You can use the built-in time/temperature programs, or alter them to suit your schedule. The Unit provides separate programs for weekdays and weekends - for both heating and cooling. You can override the programmed temperatures for as little as one programming period or for an entire vacation. • In cool weather, when the system switch is set to HEAT, the Unit will maintain cooler “set back” room temperatures to save energy. It will then change to warmer “comfort” settings — all automatically, at specified times during the day. • In warm weather, when the system switch is set to COOL, the Unit will maintain warmer “set back” room temperatures to save energy. It will then change to cooler “comfort” settings - all automatically, at specified times during the day. • A large liquid crystal display shows time, day of the week, and room and set temperatures. It will remind you when the filter should be changed in your blower and track your system’s energy usage. • Temperature swing adjustment lets you fine-tune your system for maximum comfort and economy. • A 4-minute minimum on/off time in COOL prevents your air conditioning system from being damaged. • The thermostat can be powered either by a common wire from the 24Vac transformer with two Energizer® or DURACELL® "AA" size alkaline batteries as backup or exclusively by two Energizer® or DURACELL® "AA" size alkaline batteries. LUX PRODUCTS CORPORATION • Mt. Laurel, New Jersey 08054, USA 43343-04 I M P O R T A N T ! Thank you for your confidence in our product. To obtain the best results from your investment, please read these instructions and acquaint yourself with your purchase before installing your new thermostat. Then follow the installation procedures, one step at a time. This will save you time and minimize the chance of damaging the thermostat and the systems it controls. These instructions may contain information beyond that required for your particular installation. Please save for future reference. READ INSTALLATION INSTRUCTIONS FIRST C A U T I O N • Your thermostat is a precision instrument. Please handle it with care. • Turn off electricity to the appliance before installing or servicing thermostat or any part of the system. Do not turn electricity back on until work is completed. • Do not short (jumper) across electric terminals at control on furnace or air conditioner to test the system. This will damage the thermostat and void your warranty. • All wiring must conform to local codes and ordinances. • This thermostat is designed for use with 24 volt and millivolt systems. The thermostat should be limited to a maximum of 1.0 amps; higher amperage may cause damage to the thermostat. If you are in doubt, call your utility company. PSPH521 SERIES PROGRAMMABLE HEAT PUMP THERMOSTAT Complete, Easy To Read Programming And Installation Instructions Inside MORN DAY EVE NIGHT DOWN UP SET WEEKDAY PROGRAM HOLD RESET NEXT SET DAYTIME SET WEEKEND PROGRAM RUN EMER HEAT OFF COOL FAN AUTO ON SIMPLIFIED INSTRUCTIONS TO SET PROGRAMS • Rotate Dial to SET WEEKDAY, SATURDAY or SUNDAY PROGRAM. • Press UP/DOWN to adjust start time. • Press NEXT. • Press UP/DOWN to adjust temperature. • Press NEXT. • Repeat as needed or rotate dial to RUN to stop Programming. TEMPORARY TEMPERATURE OVERRIDE •Press UP/DOWN to adjust set temperature. •To clear OVERRIDE press UP/DOWN until original set temperature appears or wait for the start tf the next period. TEMPERATURE HOLD • Press HOLD. Adjust temperature as desired with UP/DOWN. •To clear, press HOLD again. • Press UP/DOWN to set time. TO SET TIME & DAY • Rotate Dial to SET WEEKDAY or WEEKEND PROGRAM • Press UP to change current day. • Press NEXT. Rotate the dial to the RUN position to close the door. The Active Program Period Liquid Crystal Display Fan Switch System Switch Easy to follow instructions LUX Speed Dial® Thermostat Body The Set Temperature Thermostat Cover HEAT OFF COOL AUTO ON FAN RESET HOLD NEXT RUN FILTER SET SUNDAY PROGRAM SET SATURDAY PROGRAM SET WEEKDAY PROGRAM SET DAY/TIME DOWN UP 1500 P a t e n t s P e n d i n g MO DAY HEAT PM SIMPLIFIED INSTRUCTIONS • Press UP/DOWN to set time. TO SET PROGRAMS • Rotate Dial to SET WEEKDAY TEMPORARY TEMPERATURE OVERRIDE •Press UP/DOWN to adjust set temperature. •To clear OVERRIDE press UP/DOWN until original set temperature appears or wait for the start tf the next period TO SET TIME & DAY • Rotate Dial to SET DAY/TIME. • Press UP to change rr t d HEAT OFF COOL AUTO ON FAN RESET HOLD NEXT RUN FILTER SET SUNDAY PROGRAM SET SATURDAY PROGRAM SET WEEKDAY PROGRAM SET DAY/TIME DOWN UP 1500 P a t e n t s P e n d i n g MO DAY HEAT PM SIMPLIFIED INSTRUCTIONS • Press UP/DOWN to set time. TO SET PROGRAMS • Rotate Dial to SET TEMPORARY TEMPERATURE OVERRIDE •Press UP/DOWN to adjust set temperature. •To clear OVERRIDE press UP/DOWN until original set temperature appears or wait for TO SET TIME & DAY • Rotate Dial to SET DAY/TIME. • Press UP to change DOWN UP MO DAY HEAT PM Choose Heat or Cool Set Day & Time Installs Easily Easy as 1–2–3 INSTALLATION AND OPERATING INSTRUCTIONS FEATURES WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only. Energizer® is a registered trademark of Eveready Battery Company, Inc. DURACELL® is a registered trademark of The Gillette Company, Inc. INSTALLATION Please read all instructions carefully before beginning installation. TOOLS REQUIRED #1 Phillips screwdriver (small) Drill with 3/16-in. (4.8mm) bit THERMOSTAT LOCATION On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations, follow the guidelines listed below. 1. Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, and in a room that is used often. 2. Do not install it where there are unusual heating conditions, such as: in direct sunlight; near a lamp, radio, television, radiator, register, or fireplace; near hot water pipes in a wall; near a stove on the other side of a wall. 3. Do not locate in unusual cooling conditions, such as: on a wall separating an unheated room; or in a draft from a stairwell, door, or window. 4. Do not locate in a damp area. This can lead to corrosion that will shorten thermostat life. 5. Do not locate where air circulation is poor, such as: in a corner or an alcove; or behind an open door. 6. Do not install the unit until all construction work and painting has been completed. 7. This thermostat does not require leveling. C A U T I O N To avoid electrical shock and to prevent damage to the furnace, air conditioner, and thermostat, disconnect the power supply before beginning work. This can be done at the fuse box, at the circuit breaker, or at the appliance. OFF REMOVING THE OLD THERMOSTAT Switch electricity to the furnace and air conditioner OFF; then proceed with the following steps. 1. Remove cover from old thermostat. Most are snap-on types and simply pull off. Some have locking screws on the side. These must be loosened. 2. Note the letters printed near the terminals. Attach labels (enclosed) to each wire for identification. Remove and label wires one at a time. Make sure the wires do not fall back inside the wall. 3. Loosen all screws on the old thermostat and remove it from the wall. MOUNTING THE UNIT ON THE WALL 1. Strip insulation 3/8 in. (9.5mm) from wire ends and clean off any corrosion. 2. Fill wall opening with non-combustible insulation to prevent drafts from affecting the thermostat. 3. Press up on the button on bottom of thermostat and swing the body away from the base and up to remove the body from the base. C A U T I O N Read instructions carefully before removing any wiring from existing thermostat. Wires must be labeled before they are removed. When removing wires from their terminals, ignore the color of the wires since these may not comply with the standard. N O T E If you are mounting the base to a soft material like plasterboard or if you are using the old mounting holes, the screws may not hold. Drill a 3/16-in. (4.8mm) hole at each screw location, and insert the plastic anchors provided. Then mount the base as described below. C A U T I O N Be careful not to drop the body or disturb electronic parts. Leave the cover closed while the body is being removed from the base. E G Y R O W2 B C TERMINALS SCREW ANCHORS BASE Attaching Wires 4. Hold the base against the wall, with the wires coming through wherever it is convenient for wiring. Route the wires to below the terminal block. Position the base for best appearance (to hide any marks from an old thermostat). Attach the base to the wall with the two screws provided.
Similar Manuals in the Thermostat Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Grohe Automatic 2000 compact |
Automatic 2000 compact (Thermostat ePDF User Guide, #8O1T48) |
14 | 965 | 193 | 31-08-2026 | view all manuals | |
ascon W09 |
Guide: ascon W09 (L2KN72, Upd.14-08-2026) |
8 | 1248 | 250 | 14-08-2026 | view all manuals | |
Carel Clima |
Clima (Thermostat ePDF User Guide, #3399WW) |
40 | 184 | 34 | 13-03-2026 | view all manuals | |
Honeywell YRTH7500D1009 - 5 Day Program Thermostat |
Honeywell Thermostat Quick installation manual (File: PDF, 15-07-2026) |
60 | 2.41 Mb | 1176 | 189 | 15-07-2026 | view all manuals |
Belux TI-N |
Belux TI-N Manual (Instruction for installation, assembly and operation), @F616LD |
2 | 627 | 138 | 22-04-2026 | view all manuals | |
Dryton MiTime T710R |
MiTime T710R (Thermostat ePDF User Guide, #GF3GH6) |
2 | 895 | 197 | 11-05-2026 | view all manuals |