MARINE TECHNOLOGIES SAFE-T-ALERT MGD-1 Manuals
1 pdf manual(s) MARINE TECHNOLOGIES SAFE-T-ALERT MGD-1 for free download (Document Types: Operation & user’s manual)
MARINE TECHNOLOGIES SAFE-T-ALERT MGD-1 Operation & user’s manual [PDF] (2 pages)
- Identifier: id-2358686
- Brand: MARINE TECHNOLOGIES
- Device: MARINE TECHNOLOGIES SAFE-T-ALERT MGD-1 Security Sensors
- Type: Operation & user’s manual, PDF
- Key Aspects: Routine Functionality Testing, Cleaning and Sanitization Methods, Common Issue Diagnostic Flows
- UPD Date: 07.05.2026
- Source File: 1928919.pdf
- Pages: 2
- Description: Installation instructions for the MARINE TECHNOLOGIES SAFE-T-ALERT MGD-1.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
PROCEDURES TO TAKE DURING AN ALARM ! WARNING: THE ACTUATION OF THIS DETECTOR INDICATES THE PRESENCE OF DANGEROUS LEVELS OF GASOLINE FUMES/VAPORS THAT COULD CAUSE AN EXPLOSION OR FIRE IF NO ACTION IS TAKEN: 1) Turn off all electrical equipment, generator, extinguish all open flames (oven, cook top, smoking materials etc.). 2) Turn off the engine(s) if safe navigation conditions exist. 3) Open the engine compartment, ports, hatches and doors and ventilate the area. 4) If you are at shore evacuate the boat. Do not return until the area is ventilated and the detector has returned to normal standby condition. 5) Proceed with caution and locate and repair the cause of the leak. Seek a qualified technician if necessary. 6) Do not start or use the boat until the necessary repairs were made. TROUBLE SHOOTING GUIDE YELLOW LED Won’t Turn ON/OFF when pressed Wire connections, missing or blown fuse, reversed wires, or defective unit Locked in WAIT (more than 4-5 minutes) Replace Sensor Block SA-186-SB No Beep and WARNING (RED) Lights Blink Return for repair or replacement When TEST/MUTE is Pressed Alternate Blink on RED GREEN Lights No communication with sensor block, check for RED LED light ON at Sensor block, if on return for repair or replacement. SPECIFICATIONS Power Supply: 12 VDC Operational Voltage: 8 to 15 VDC Power Draw: 100mA amps @ 1VDC Operating Temp: -220 F - 1600 F Alarm Threshold: < 20% LEL of Gasoline Fumes / Vapor Other Gases Detected: Alcohol, Acetone, Hydrogen and most other Hydrocarbon gases LIMITED PRODUCTS WARRANTY MTI INDUSTRIES, INC. Warrants to the original purchaser that this detector will be free from defects of material or workmanship for a period of Two (2) years. If proven to have been defective in original materials or workmanship and returned, delivery costs prepaid, MTI INDUSTRIES, INC. will repair or replace this product free of charge. LIMITS OF WARRANTY Repair or replacement is your exclusive remedy under this limited warranty or any other warranty (including any implied warranty of merchantability for a particular purpose). Any and all implied warranties or merchantability or fitness for a particular purpose shall be limited to the warranty period from the original date of purchase. MTI INDUSTRIES, INC., its dealers and distributors shall in no case be responsible or in any way liable for any incidental or consequential damages for any reason. Some states do not allow the limitation or exclusion of incidental or consequential damages or allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. This warranty gives you specific rights, and you may also have other rights which may vary from state to state. WARRANTY RETURN POLICY Warning- opening this product for any reason voids the warranty. There are no user serviceable parts in the cases. No product will be accepted for repair or replacement without an authorization number (RA). RA numbers may only be issued by MTI or authorized distributors. Include an explanation of the problem, the original dated sales receipt, and your return address. Send, shipping prepaid, to MTI Industries, Inc. 206C Tequesta, FL 32541 E-mail [email protected] www.mtiindustries.com MARINE TECHNOLOGIES, INC. SAFE-T-ALERT™ MGD-1 and MGD-1XL MARINE GASOLINE FUME DETECTOR USER’S MANUAL IMPORTANT PLEASE READ CAREFULLY AND SAVE This manual contains important information. Purchasers who install this detector for use by others must leave this manual with the user. ALL RIGHTS RESERVED REV: MGD1XL 02142019-1 ! WARNING: LIMITATIONS OF FUME DETECTORS Gasoline Fume detectors will not work without power. Examples causing no detector power are an open circuit breaker, blown or missing fuse, broken wire or improper wire crimp connection. CAUTION - This detector will only indicate the presence of gasoline fumes at the sensor. The sensor cannot monitor a compartment that is separated by a bulkhead. Gasoline fumes may be present in other areas. MTI recommends that sensors be installed in compartments where gasoline fumes may accumulate. Gasoline fume detectors may not be heard. The alarm loudness is designed to meet or exceed regulatory standards; however, the alarm may not be heard if detectors are installed in remote locations. The alarm may not be heard by persons who are hard of hearing. ! WARNING: WHY EVERY BOAT NEEDS A FUME DETECTOR Gasoline vapors can develop in fuel pumps, fuel tanks, fuel lines, carburetors and fuel systems. The SAFE-T-ALERT™ MGD-1 and MGD-1XL detectors are for Marine Use. They are an early warning monitor, designed to notify the user when 20% or less of the lower explosive limit of gasoline fumes are present in the monitored area. Power Supply: 12 vDC Recommended Wire Gauge: 18 Ga. Wire Color Code: Red (+) Black (-) Fuse: In-Line 1 amp to the Red lead of the panel WHERE TO INSTALL THE PANEL AND SENSOR • Locate the control panel in the helm area where it can easily be seen and heard. • Locate the sensor block on a forward bulkhead wall about starter height. WHERE NOT TO INSTALL THE PANEL AND SENSOR • DO NOT mount the control panel under a cowling, or glass or plastic panel where it my not be seen or heard. • DO NOT locate the sensor block above batteries. Hydrogen from the batteries may cause nuisance alarms. • DO NOT locate the sensor block behind any obstruction that will prevent air flow to the sensor. • DO NOT locate the sensor block on the aft bulkhead. Water in the sensor block could cause permanent damage to the sensor block. • DO NOT locate the sensor within 12 inches (304.8 mm) of exhaust lines. High heat may cause false alarms.
Similar Manuals in the Security Sensors Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
hager H 400 |
PDF Manual (@G49QQO), hager H 400 Security Sensors (16-07-2026) |
4 | 1150 | 219 | 16-07-2026 | view all manuals | |
LaserLiner MultiFinder Pro |
User Guide: LaserLiner MultiFinder Pro (X82PYZ, Upd.17-06-2026) |
52 | 967 | 146 | 17-06-2026 | view all manuals | |
Niko 10-826 |
PDF User Manual (@1G84JU), Niko 10-826 Security Sensors (24-04-2026) |
52 | 248 | 58 | 24-04-2026 | view all manuals | |
Texecom Premier Elite CO-W |
Security Sensors #LGCBX8 |
2 | 415 | 67 | 24-05-2026 | view all manuals | |
B.E.G. LUXOMAT PD4-M-DALI |
Security Sensors #YW9ZFE |
3 | 1492 | 284 | 05-04-2026 | view all manuals | |
Leedarson Motion Sensor Pet Immunity Z-Wave 700 |
Leedarson Security Sensors Quick start manual (File: PDF, 08-07-2026) |
13 | 301 | 73 | 08-07-2026 | view all manuals |