Printed in Japan Mitutoyo Corporation, 1-20-1 Sakado, Takatsu-ku, Kawasaki City, Kanagawa 213-8533, Japan Date of publication: April 10, 2018 1. Names of Components ② ① ③ ④ ⑤ ⑩ ⑨ ⑥ ⑧ ⑦ ⑪ ⑫ CGF-X ① Clamp screw ② Indicator holder ③ Grip ④ Pipe (outer sleeve) ⑤ Measuring head ⑥ Supporting nut ⑦ Anvil ⑧ Adjustment washer ⑨ Guide ⑩ Contact point (contact rod) ⑪ Guide stopper screw ⑫ Contact rod holder Tips No guide (guide plate) is provided with CG-S10A. 2. Preparation for Measurement 1) Setup NOTICE • Confirm that the measuring head or screw is not loosened before use. • Do not insert, remove, or turn the indicator with the clamp screw tightened, as it will lead to breakage. • If the insertion hole of the indicator holder is accidentally deformed, correct it by inserting a ø8 mm rod for the metric type and a ø9.53 mm rod for the inch type. • Secure fixation may be impossible when the indicator or the indicator holder insertion hole or the clamp screw is dirty. Clean them in advance. 1 3 Dial protection cover Clamp screw 1 Loosen the clamp screw and insert the indicator into the indicator holder. 2 Tighten the clamp screw to fix the indicator. Tips Firm tightening is possible by turning with an object such as a coin inserted in the groove on the clamp screw head. 3 When required, attach a dial protection cover (optional depending on models). 4 For models with a measurement range of 160 mm or more, the direction of the guide unit must be switched. 1. Push the guide until it hits the end lightly. 2. Turn 90 degrees clockwise. 3. Let go. ⇨ The guide returns to the reference point position, and the product is ready for measurement. 1 2 Safety Precautions To ensure operator safety, use this product in conformance with the directions, functions and specifications given in this User’s Manual. Use under other conditions may compromise safety. NOTICE • Do not disassemble or modify. This may cause damage. • Do not use or store the product in a place with sudden temperature changes. Adapt the product to room temperature before use. • Do not store the product in a place with high humidity or a lot of dust. • Do not apply impact or excessive force to this product. • Be sure to perform reference point setting before measurement. • Remove dust, cutting chips, etc. before and after use. • After use, clean and perform anti-rust treatment for the body, anvils, adjustment washers, etc. Insufficient cleaning may cause accuracy or operation to suffer. • For periodic calibration or precision measurement, wear thick gloves in order to reduce changes in the indicated value caused by the transmission of body temperature. • Indicators with rubber bellows such as waterproof dial gages cannot be used. Tips The bore gage is a comparator. It will not function as a measuring instrument if used alone. An indicator such as a dial gage and a reference gage such as a set ring or micrometer are required to use the product. Bore Gage User's Manual No.99MAJ005A CG-SA CG-AX CGB-X CGF-X CGM-X Model/Code No. List Model Code No. CG-S10A 511-209 CG-S18A 511-201 CG-S.4"A 511-214 CG-S.7"A 511-205 CGB-35X 511-761 CGB-60X 511-762 CGB-150X 511-763 CGB-160X 511-764 CGB-1.4"X 511-781 CGB-2.5"X 511-782 Model Code No. CGB-6"X 511-783 CGB-6.5"X 511-784 CG-35AX 511-701 CG-60AX 511-702 CG-150AX 511-703 CG-160AX 511-704 CG-250AX 511-705 CG-400AX 511-706 CG-1.4"AX 511-731 CG-2.5"AX 511-732 Model Code No. CG-6"AX 511-733 CG-6.5"AX 511-734 CG-10"AX 511-735 CG-16"AX 511-736 CGF-35X 511-415 CGF-60X 511-416 CGF-150X 511-417 CGF-1.4"X 511-418 CGF-2.4"X 511-419 CGF-6"X 511-420 Model Code No. CGM-100X 511-803 CGM-160X 511-804 CGM-250X 511-805 CGM-400X 511-806 CGM-600X 511-807 CGM-800X 511-808 CGM-4"X 511-833 CGM-6.4"X 511-834 CGM-10"X 511-835 CGM-16"X 511-836 Model Code No. CGM-24"X 511-837 CGM-32"X 511-838 en
Mitutoyo CG-S10A: Measuring Instruments Category Related Instructions
INSTRUCTION MANUAL For...は専用機種。複数の場合は「/」で区切る。 不要の場合はとる。 形名を入力。 複数の場合は「/」で区切る。 3274 品名を入力。 CLAMP ON PROBE Device setup guide for the Hioki 3274 Test Equipment. This guide includes performance guidelines, energy usage, diagnostic information.
Air Comm Systems Inc. 1640 W. Acoma Blvd., Suite A-118 Lake Havasu City, AZ 86403 Phone (928) 854-5402 FAX (928) 854-8919 E-Mail [email protected] Air Comm Systems, Inc. Receive Audio Indicator Panel Installation Manual ACS 296 Revision 1.1 AirComm Airborne A Device instruction manual for the Air Comm Systems ACS 296 Touch Panel. The manual elaborates on features and application scenarios, usage examples, reset instructions, safety precautions.
Art. 0715 53 325 LACKSCHICHTDICKENMESSGERÄT PAINT COATING THICKNESS METER Art. 0715 53 790 Originalbetriebsanleitung Translation of the original operating instructions Traduzione delle istruzioni di funzionamento originali Traduction des instructions de serv User operation guide for the wurth 0715 53 790 Measuring Instruments. It describes usage and technical overview, user settings, connectivity options, operating conditions.
Cleaning instructions H-2000-4098-03-B Întretinere NC4 - Curatare sistem optic NC4 Servicing - Cleaning the optics Entretien NC4 - Nettoyage des composants optiques Limba romana English Français Device technical manual for the Renishaw NC4 Measuring Instruments. This reference manual explains repair references, software configuration, backup procedures, installation guides.