Novus TagTemp Stick Manuals
2 pdf manual(s) Novus TagTemp Stick for free download (Document Types: Instruction manual)
Novus TagTemp Stick Instruction manual [PDF] (5 pages)
- Identifier: id-814439
- Brand: Novus
- Device: Novus TagTemp Stick Data Loggers
- Type: Instruction manual, PDF
- Key Aspects: Error Code Explanations, Additional Modules and Accessories Guide, Device Specifications Overview
- UPD Date: 27.07.2026
- Source File: 825325.pdf
- Pages: 5
- Description: Setup instructions for the Novus TagTemp Stick.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
NOVUS AUTOMATION 1/5 TagTemp Stick TEMPERATURE LOGGER – INSTRUCTIONS MANUAL V1.0x B 1 INTRODUCTION TagTemp Stick is an electronic temperature recorder. A sensor measures the temperature and the read value is stored in memory. This data can later be downloaded to a computer for display and analysis in the form of tables or charts. The LogChart II software enables to set up the equipment operation mode. It is also used for viewing acquisitions. Other parameters such as end of measurements, logging interval, etc., are easily defined through the LogChart II software. Acquisitions can also be exported to be analyzed in other applications, such as spreadsheet programs. 1.1 IDENTIFICATION The identification label is on the equipment body. Check if the features described are in accordance with your order. Status indicator: This visual indicator reports the status of operation of equipment through the number of flashes that occur in an interval of five seconds. The states of operation are: • One flash: The device is waiting to start the log in memory (standby) or completed a series of logs in memory; • Two flashes: the device is performing logs in memory; • Three flashes: the device is or has gone through an alarm condition and is not performing logs in memory; • Four flashes: the device is or has gone through an alarm condition and is performing logs in memory. 2 TECHNICAL DATA Measure Range Temperature: –20.0 °C to 70.0 °C. Accuracy ± 0.5 °C @ 25 ºC. ± 1 °C max. along the entire measured range. Note: A measure error can be fixed using the OFFSET parameter in the LogChart II software. Measurement response time (90 %) 10 min. in air. Measurement Resolutions Temperature: 0.1 °C. Memory capacity 32.000 (32 k) logs. Measurement Interval 5 seconds min. 18 hours max. Supply 3.0 V lithium battery (CR2032), built-in Estimated battery autonomy • More than 400 days – Sampling rate of 1 minute. • More than 500 days – Sampling rate of 30 minutes. Operating temperature From -20 °C to 70 °C Housing Polyamide Protection Product suitable for applications requiring up to IP67 degree of protection. See item "Special Care". Dimensions 78 x 23 x 10 mm Equipment -PC data transfer time Proportional to the number of records. 20 seconds to 32.000 records. PC Interface Connector USB LogChart ll software operation environment Configurator software for Windows ® 8, 7 and XP. Menus in Portuguese, English or Spanish. Sets up, reads and displays data on the screen. 3 OPERATION It is only possible to operate the equipment after the LogChart II software is installed to a PC, according to the steps described in LogChart II Software section of this manual. The communication between equipment and PC is performed with the aid of the USB-A connector. The equipment operation mode set up is defined in advance by using the LogChart II software. Each setting must be defined and the consequences observed. The equipment starts and stops logging as defined in settings.
Novus TagTemp Stick Instruction manual [PDF] (11 pages)
- Identifier: id-2339568
- Brand: Novus
- Device: Novus TagTemp Stick Data Loggers
- Type: Instruction manual, PDF
- Key Aspects: Device Specifications Overview, Initial Startup Checklist, Product Performance Metrics
- UPD Date: 03.04.2026
- Source File: 1948037.pdf
- Pages: 11
- Description: Device setup guide for the Novus TagTemp Stick.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
NOVUS AUTOMATION 1/11 TagTemp-S TEMPERATURE DATA LOGGER - INSTRUCTION MANUAL V1.0x 1 INTRODUCTION TagTemp-S is an electronic temperature recorder. The temperature measured by the sensor is recorded in equipment internal memory. This data is transferred through a smartphone equipped with an embedded NFC interface or by an NFC interface connected to a computer through an USB port (both not included). LogChart-NFC application for ANDROID™ and the Nx Software for Windows® are the tools used to configure the operating mode, transfer and display data. The acquisition start and end parameters, logging interval, setpoint alarms and other parameters can be easily defined using these applications. The operating manual and Nx Software can be downloaded from the manufacturer's website. The ANDROID™ LogChart-NFC app can be downloaded from Google Play Store. 2 MECHANICAL INSTALLATION TagTemp-S can be installed using a double-sided adhesive tape on the back of the device, taking care not to stick it over the identification tag. Another way is to use the blister hole to attach the transmitter. 3 TECHNICAL FEATURES Operating temperature -30 °C to 60 °C Storage temperature From -30 °C to 65 °C. Measuring range Temperature: -30.0 °C to +60.0 °C. Accuracy of measurement ±1 °C max. over the full measuring range. Note: You can correct the measurement error in the OFFSET parameter using the configuration software. Measurement resolution Temperature: 0.1 °C / 0.1 °F Memory Capacity 4020 registers. Interval between Measurements 1 minute min. 4 hours max. (240 minutes). Power Supply 3.0 V lithium battery (CR2032), built-in, non-replaceable. Battery life (estimated) Above 2 years at a 5-minute acquisition interval. Dimensions 37 x 57 x 8 mm RF Interface ISO 15693 (NFC-V) compatible. Data transfer time between register and smartphone Approx. 20 seconds (depends on the smartphone processing speed). LogChart-NFC Application ANDROID™ version: 4.0 or above. Languages: Portuguese or English. NFC interface for the computer USB to NFC interface (optional), compatible with Nx Software for Windows®. Case Polyvinyl Chloride (PVC) Degree of protection All electronics are protected by the housing. IP65 compatible. Certification CE
Similar Manuals in the Data Loggers Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Xylem ebro EBI IF Series |
Xylem Data Loggers Manual (File: PDF, 06-07-2026) |
40 | 69 | 11 | 06-07-2026 | view all manuals | |
Onset HOBO |
Onset HOBO Guide (Operation & user’s manual), @32LAHX |
8 | 82 | 19 | 27-06-2026 | view all manuals | |
Symmetricom TimeProvider 500 series |
Data Loggers #C9XCGY |
88 | 396 | 80 | 05-06-2026 | view all manuals | |
PCE Instruments PCE-SDL1 |
PDF User Guide (@3O56HM), PCE Instruments PCE-SDL1 Data Loggers (15-03-2026) |
34 | 1199 | 300 | 15-03-2026 | view all manuals | |
Itm Hanna Instruments HI144 T-Logger |
Data Loggers #6X3476 |
5 | 250 | 38 | 03-09-2026 | view all manuals | |
TESTO 175-S1 |
#7C5FN5: 175-S1 Data Loggers Short instruction manual |
8 | 950 | 200 | 18-07-2026 | view all manuals |