Red Ion CUB5 Manuals

1 pdf manual(s) Red Ion CUB5 for free download (Document Types: Manual )

Red Ion CUB5 Manual  [PDF] (16 pages)

  • Identifier: id-2325307
  • Brand: Red Ion
  • Device: CUB5 Measuring Instruments
  • Type: PDF
  • Key Aspects: Information on Regular Maintenance, Documentation and Revision History, Package Contents and Accessories List
  • UPD Date: 01.09.2026
  • Source File: 1962299.pdf
  • Pages: 16
  • Description: Device operation guide for the Red Ion CUB5.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 � LCD, REFLECTIVE OR GREEN/RED LED BACKLIGHTING � 0.46" (11.7 mm) HIGH DIGITS � OPTIONAL SETPOINT OUTPUT MODULES � OPTIONAL SERIAL COMMUNICATIONS MODULE (RS232 or RS485) � OPERATES FROM 9 TO 28 VDC POWER SOURCE � PROGRAMMABLE SCALING FOR COUNT AND RATE � BI-DIRECTIONAL COUNTING, UP/DOWN CONTROL � QUADRATURE SENSING (UP TO 4 TIMES RESOLUTION) � BUILT-IN BATCH COUNTING CAPABILITY � DISPLAY COLOR CHANGE CAPABILITY AT SETPOINT OUTPUT � NEMA 4X/IP65 SEALED FRONT BEZEL MODEL CUB5 - MINIATURE ELECTRONIC 8-DIGIT DUAL COUNTER AND RATE INDICATOR GENERAL DESCRIPTION The CUB5 provides the user the ultimate in flexibility, from its complete user programming to the optional setpoint control and communication capability. The meter can be programmed as a single or dual counter with rate indication capability. The display can be toggled either manually or automatically between the selected displays. The CUB5 display has 0.46" (11.7 mm) high digits. The LCD is available in two versions, reflective (CUB5R000) and backlight (CUB5B000). The backlight version is user selectable for green or red backlighting with variable display intensity. The counter is programmable for one of eight different count modes, including bi-directional and quadrature. When programmed as a dual counter, each counter has a separate scale factor and decimal points. In the counter/rate indicator mode, each have their own scaling and decimal point read-outs in different engineering units. The internal batch counter can be used to count setpoint output activations. The meter has two separate inputs which provide different functions depending on which operating mode is selected. Input A accepts the signal for the Count and/or Rate displays, while Input B accepts the signal for the Count display or direction control. In the anti-coincidence mode, both inputs are monitored simultaneously so that no counts are lost. The resulting display can be chosen as the sum or difference of the two inputs. The Rate Indicator has programmable low (minimum) and high (maximum) update times to provide optimal display response at any input frequency. There is a programmable user input that can be programmed to perform a variety of functions. The capability of the CUB5 can be easily expanded with the addition of option modules. Setpoint capability is field installable with the addition of the single setpoint relay output module or the dual setpoint solid state output module. Serial communications capability for RS232 or RS485 is added with a serial option module. The CUB5 can be powered from an optional Red Lion Micro-Line/Sensor Power Supply (MLPS1000), which attaches directly to the back of a CUB5. The MLPS1 is powered from 85 to 250 VAC and provides up to 400 mA to drive the unit and sensors. COUNTER The CUB5 receives incoming pulses and multiplies them by the Count Scale Factor to obtain the desired reading for the count display. Input A accepts the signal for the count and Input B is used for quadrature, dual counter, anti- coincidence counting, or up/down control counting. RATE The rate indicator utilizes the signal at Input A to calculate the rate value using a time interval method (1/tau). The unit counts on the negative edge of the input pulses. After the programmed minimum update time elapses and the next negative edge occurs, the unit calculates the input rate based on the number of edges that occurred during the elapsed time. The input rate is then multiplied by the rate scaling value to calculate the rate display. At slower rates, averaging can be accomplished by programming the rate minimum update time for the desired response. Extensive scaling capabilities allow practically any desired reading at very slow count rates. SAFETY SUMMARY All safety related regulations, local codes and instructions that appear in this literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Do not use this meter to directly command motors, valves, or other actuators not equipped with safeguards. To do so can be potentially harmful to persons or equipment in the event of a fault to the meter. Bulletin No. CUB5-F Drawing No. LP0584 Released 1/08 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net CAUTION: Risk of Danger. Read complete instructions prior to installationand operation of the unit. CAUTION: Risk of electric shock. Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15" (54.6) H x 3.00" (76.2) W. C US LISTED US LISTED UL R IND. CONT. EQ. 51EB DIMENSIONS In inches (mm)

CUB5: Related Instructions

MobilityPro BT-5600 Series
Red Ion MobilityPro BT-5600 Series
02.07.2026 2 pages

CONNECT. MONITOR. CONTROL. © 2014 Red Lion Controls. All Rights Reserved 1 QUICK START GUIDE MobilityProTM BT-5600 Series Aeris Installation guide for the Red Ion MobilityPro BT-5600 Series Modem. This documentation details backup procedures, component overview, installation steps.

CUB5TC
Red Ion CUB5TC
09.05.2026 12 pages

1 MODEL CUB5TC - MINIATURE ELECTRONIC 5-DIGIT THERMOCOUPLE METER GENERAL DESCRIPTION The CUB5 provides the user the ultimate in flexibility, from its complete u User support manual for the Red Ion CUB5TC Measuring Instruments. This documentation covers operational guidelines, safety features, installation guides, technical specifications.

CUB7W
Red Ion CUB7W
04.04.2026 4 pages

1 ! COUNT INPUT FROM 10 to 300 VAC/DC ! LCD, POSITIVE IMAGE REFLECTIVE OR NEGATIVE IMAGE TRANSMISSIVE WITH YELLOW/GREEN OR RED LED BACKLIGHTING (9 to 28 VDC pow Product reference manual for the Red Ion CUB7W Cash Counter. It outlines maintenance guidelines and installation procedures, compatibility information, warranty information, network configuration.

CUB7T0
Red Ion CUB7T0
25.03.2026 4 pages

2.00 (50.8) 1.10 (27.9) 0.11 (2.8) 0.10 (2.5) 1.56 (39.6) 0.87 (22.0) 0.874 1.77 (22.2 ) (45 ) +0.024 -0.000 +0.6 -0.0 +0.012 -0.000 +0.3 -0.0 8537421 Technical setup manual for the Red Ion CUB7T0 Timer. It offers guidance on shutdown procedures, usage procedures, compatibility information, error handling.

TSC
Red Ion TSC
01.09.2026 8 pages

(134.4) (137.4) .40 (49.5) (10.2) PAR 1.95 PGM %PW DSP AL1 MAN OP1 AL2 (96.5) 3.80 5.29 5.41 (44.4) 1.75 3.60 (91.4) (45 ) +.6 (92 ) 3.62 -.0 +.03 -.0 +. User setup guide for the Red Ion TSC Temperature Controller. This guide offers guidance on software installation, calibration steps, troubleshooting tips.

APLI
Red Ion APLI
08.07.2026 5 pages

1 3.80 (96.5) 1.95 (49.5) .3 .1 (2.5) (7.6) 4.20 (106.7) 1.75 (44.5) 3.62 1.77 (45 ) (92 ) +.03 -.00 +.8 -.0 +.02 -.00 +.6 -.0 1638  TWO MULTI-RANGE U Technical setup manual for the Red Ion APLI Measuring Instruments. The guide offers support information and usage recommendations, troubleshooting, setup tips, component replacement.

Similar Manuals in the Measuring Instruments Category

DF2
Ecomatik DF2
14.06.2026 5 pages

Dendrometer Muenchner Str. 23 D-85221 Dachau/Germany Tel.: +49 8131 260 738 Fax: +49 8131 260 736 e-mail: [email protected] website: www.ecomatik.de Frui Professional manual for the Ecomatik DF2 Measuring Instruments. This guide includes product specifications, troubleshooting guides, installation guides, supported accessories.

i400s
Fluke i400s
05.07.2026 8 pages

® PN 2414327 February 2005 © 2005 Fluke Corporation. All rights reserved. Printed in U.S.A. 1 i400s AC Current Clamp Calibration Information Introduction XWWa Service manual for the Fluke i400s Measuring Instruments. The manual contains instructions for shutdown procedures, system configuration, service contacts.

RSA6114A
Tektronix RSA6114A
07.06.2026 84 pages

x RSA6100A Series Real-Time Spectrum Analyzers RSA5100A Series Real-Time Signal Analyzers ZZZ Quick Start User Manual *P071283800* 071-2838-00 Product instruction handbook for the Tektronix RSA6114A Measuring Instruments. The document provides guidance on safety and basic operation, reset instructions, configuration options, security instructions.

LD6
Trotec LD6
08.07.2026 11 pages

TRT-BA-LD6-TC2017-11-002-EN LD6 EN OPERATING MANUAL SOUND LOCATOR Product setup manual for the Trotec LD6 Measuring Instruments. The guide explains setup and diagnostic information, installation procedures, connectivity options.