Red Ion CUB7T0 Manuals

1 pdf manual(s) Red Ion CUB7T0 for free download (Document Types: Manual )

Red Ion CUB7T0 Manual  [PDF] (4 pages)

  • Identifier: id-1399331
  • Brand: Red Ion
  • Device: CUB7T0 Timer
  • Type: PDF
  • Key Aspects: Efficiency and Calibration Tips, Glossary of Technical Terms, Component Longevity Optimization
  • UPD Date: 25.03.2026
  • Source File: 1328423.pdf
  • Pages: 4
  • Description: Device technical manual for the Red Ion CUB7T0.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
2.00 (50.8) 1.10 (27.9) 0.11 (2.8) 0.10 (2.5) 1.56 (39.6) 0.87 (22.0) 0.874 1.77 (22.2 ) (45 ) +0.024 -0.000 +0.6 -0.0 +0.012 -0.000 +0.3 -0.0 85374216 1  9 PROGRAMMABLE TIMER RANGES  3 (8 Digit 0.35") LCD DISPLAY OPTIONS (Reflective, Red Transmissive, Yellow/Green Transmissive) with “Timer Active” annunciator  CONTACT INPUT  REPLACEABLE INTERNAL LITHIUM BATTERY (provides up to 6 years of uninterrupted operation)  BOTH FRONT PANEL PROGRAM AND RESET BUTTONS ARE INDIVIDUALLY ENABLED  WIRE CONNECTIONS VIA SCREW CLAMP TYPE TERMINALS  FRONT PANEL AND REMOTE RESET INPUT  NEMA 4X/IP65 SEALED FRONT BEZEL DESCRIPTION The CUB7T0 is an 8-digit miniature programmable timer with large 0.35 inch (8.90 mm) high digits. It has an LCD read-out available in Positive Image Reflective (CUB7T000), Negative Image Transmissive with yellow/green backlighting (CUB7T010) or red backlighting (CUB7T020). The backlight versions require an external 9 to 28 VDC power supply. The display will wrap around from a full display of “99999999” to “00000000” when an overflow occurs. An annunciator, located in the upper left hand corner of the display, blinks at 2 Hz when the signal input is activated. The CUB7T0 operates from a switch contact or an open collector NPN transistor. The CUB7T timers use a CMOS LSI chip, mounted on a gold-plated substrate, that is electrically connected by ultrasonic wire-bonding. Proven micro-electronic assembly and manufacturing techniques provide these units with the reliability and dependability required for industrial service. The CUB7T series is housed in a lightweight, high impact plastic case with a clear viewing window. The sealed front panel with the silicone rubber buttons meets NEMA 4X/IP65 specifications for wash-down and/or dusty environments, when properly installed. SAFETY SUMMARY All safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Do not use this unit to directly command motors, valves, or other actuators not equipped with safeguards. To do so, can be potentially harmful to persons or equipment in the event of a fault to the unit. SPECIFICATIONS 1. DISPLAY: 8-digit LCD, 0.35" (8.90 mm) high digits. 2. POWER SOURCE: Replaceable Internal 3.0 V lithium battery to provide up to 6 years of continuous operation. (Battery life is dependent upon usage. Contacts that remain closed for long periods of time reduce battery life.) 3. BACKLIGHT POWER REQUIREMENTS: 9 to 28 VDC; 35 mA. typical, 50 mA max. Above 26 VDC, derate max. operating temperature to 40°C. Must use a NEC Class 2 or SELV rated power supply. 4. ANNUNCIATOR: Annunciator in the upper left corner of the display flashes at a 2 Hz rate when the signal input is activated. 5. SIGNAL INPUT: (LS terminal #4) Contact Input (CUB7T0xx): Switch Contact or solid state Transistor Switch to Common. Contact burden 15 μA max. A maintained closed switch to COM will actuate the timer. 6. REMOTE RESET: 15 msec min. pulse width (active low) from 3.0 V bipolar output, an open collector transistor, or a switch contact to common. 7. ACCURACY: 0.025% 8. ENVIRONMENTAL CONDITIONS: Operating Temperature Range: 0 to 50 °C Derate max. operating temperature to 40 °C above 26 VDC (Backlight versions). Storage Temperature: -30 to 80 °C Operating and Storage Humidity: 85% max. relative humidity (non- condensing) from 0 °C to 50 °C. Vibration According to IEC 68-2-6: Operational 5 to 500 Hz, in X, Y, Z direction for 1.5 hours, 5 g’s. Shock According to IEC 68-2-27: Operational 30 g's, 11 msec in 3 directions. Altitude: Up to 2000 meters 9. CONNECTIONS: Wire clamping screw terminals. Wire Strip Length: 0.3" (7.5 mm) Wire Gage: 30-14 AWG copper wire Torque: 5 inch-lbs (0.565 N-m) max 10. CERTIFICATIONS AND COMPLIANCES: SAFETY Type 4X Indoor Enclosure rating (Face only) MODEL CUB7T0 PROGRAMMABLE GENERAL PURPOSE ELECTRONIC TIMER DIMENSIONS In inches (mm) Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15" (53.4) H x 3.00" (140) W. PANEL CUT-OUT Bulletin No. CUB7T0-D Drawing No. LP0648 Released 6/09 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net CAUTION: Risk of Danger. Read complete instructions prior to installation and operation of the unit.

CUB7T0: Related Instructions

MobilityPro BT-5600 Series
Red Ion MobilityPro BT-5600 Series
25.06.2026 2 pages

CONNECT. MONITOR. CONTROL. © 2014 Red Lion Controls. All Rights Reserved 1 QUICK START GUIDE MobilityProTM BT-5600 Series Aeris Maintenance and service manual for the Red Ion MobilityPro BT-5600 Series Modem. The guide focuses on installation, maintenance guidelines, connectivity options, installation procedures.

CUB5T
Red Ion CUB5T
18.06.2026 16 pages

1  LCD, REFLECTIVE OR RED/GREEN LED BACKLIGHTING  0.46" (11.7 mm) HIGH DIGITS  7-DIGIT BI-DIRECTIONAL TIMING CAPABILITY  6-DIGIT CYCLE COUNTING Product usage manual for the Red Ion CUB5T Timer. This documentation highlights features and firmware updates, component replacement, usage recommendations.

TSC
Red Ion TSC
18.06.2026 8 pages

(134.4) (137.4) .40 (49.5) (10.2) PAR 1.95 PGM %PW DSP AL1 MAN OP1 AL2 (96.5) 3.80 5.29 5.41 (44.4) 1.75 3.60 (91.4) (45 ) +.6 (92 ) 3.62 -.0 +.03 -.0 +. Technical setup manual for the Red Ion TSC Temperature Controller. The document elaborates on device functions and safety protocols, product safety, performance details, compatibility information.

RBDLA
Red Ion RBDLA
20.08.2026 2 pages

INSTALLING AN OUTPUT BOARD 1. Remove the controller from the case. 2. Lift up on the top bezel board latch while gently pulling out on the bezel/ display board Setup and usage guide for the Red Ion RBDLA Controller. This documentation details performance optimization, installation, product safety, energy usage.

CUB7T0
Red Ion CUB7T0
31.05.2026 4 pages

2.00 (50.8) 1.10 (27.9) 0.11 (2.8) 0.10 (2.5) 1.56 (39.6) 0.87 (22.0) 0.874 1.77 (22.2 ) (45 ) +0.024 -0.000 +0.6 -0.0 +0.012 -0.000 +0.3 -0.0 8537421 User support manual for the Red Ion CUB7T0 Timer. It provides guidance on installation, operating instructions, device operation tips, user settings.

CUB5
Red Ion CUB5
30.07.2026 16 pages

1 � LCD, REFLECTIVE OR GREEN/RED LED BACKLIGHTING � 0.46" (11.7 mm) HIGH DIGITS � OPTIONAL SETPOINT OUTPUT MODULES � OPTIONAL SERIAL COMMUNICATIONS MODU Comprehensive instruction manual for the Red Ion CUB5 Measuring Instruments. It describes maintenance tasks and error codes, firmware updates, product handling, product specifications.

Similar Manuals in the Timer Category

FXY Series
Autonics FXY Series
06.09.2026 6 pages

J-36 FXY Series Specifications Features DIN W72×H36mm Of Counter/Timer With Indication Only Model Please read “Safety Considerations” in operation manua Operating handbook for the Autonics FXY Series Timer. It describes usage and repair references, troubleshooting guides, system setup, device calibration.

Chorus
Gewiss Chorus
18.07.2026 2 pages

CHORUS GW 10 582 GW 12 582 GW 14 582 230V ac - 50/60Hz 1NA 16A(AC1) / 4A(AC15) 250V ac 2 1 3 4 5 FAN L N 2 1 3 4 5 L N FAN 2 1 3 4 5 L N 2 1 3 4 5 L N ENGLISH W Instruction and reference manual for the Gewiss Chorus Timer. It explains usage scenarios and daily usage, repair references, diagnostic information, security instructions.

M Series
Fema Electronica M Series
12.04.2026 16 pages

Model M40-T Pt100/RTD Thermocouples Series M Panel meter for Pt100/RTD (2 and 3 wires), and thermocouples J, K, T, E, S, R, N, C, L and X with temperature displ Installation instructions for the Fema Electronica M Series Measuring Instruments. It explains installation, setup, and configuration options, hardware components, maintenance, performance details.

ET8415CR
Intermatic ET8415CR
26.03.2026 4 pages

Energy Controls Project: Location: Product Type: Contact/Phone: Model #: ET8415CR ET8415CR 7-Day Electronic Astronomic Time Switch The ET8415CR 7-Day Astronomic Device instruction manual for the Intermatic ET8415CR Timer. The document includes power requirements, installation procedures, operating guidelines.