Wheelock MT-12-LS Manuals
1 pdf manual(s) Wheelock MT-12-LS for free download (Document Types: Installation instructions manual)
Wheelock MT-12-LS Installation instructions manual [PDF] (9 pages)
- Identifier: id-247719
- Brand: Wheelock
- Device: MT-12-LS Smoke Alarm
- Type: PDF
- Key Aspects: User Training Recommendations, Component Overview and Descriptions, System Architecture and Design Overview
- UPD Date: 21.08.2026
- Source File: 192534.pdf
- Pages: 9
- Description: Complete device guide for the Wheelock MT-12-LS.
Click to expand and read text
P82475 K Sheet 1 of 9 273 Branchport Avenue Long Branch, NJ 07740 Thank you for using our products. (800) 631-2148 INSTALLATION INSTRUCTIONS www.wheelockinc.com MULTITONE STROBE APPLIANCES Use this product according to this instruction manual. Please keep this instruction manual for future reference. GENERAL: The Multitone Strobe Appliances are UL Listed under Standard 1971 for Emergency Devices for the Hearing Impaired and UL Standard 464 for Audible Signal Appliances. The LSM strobes are listed at 15 candela under UL Standard 1971 and meet 75 candela intensity on axis with low current draw. They are listed for indoor use with the backboxes specified in these instructions (See Mounting Options). Models with LS, MS and IS strobes are Listed for wall or ceiling mounting; models with LSM strobes are Listed for wall mounting. The Multitone Strobe Appliances use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan lens to provide maximum visibility and reliability for effective visible signaling. Multitone Strobe Appliances can be field set to produce any one of eight commonly used alarm tones. Sound output can be field set to provide either HIGH (HI) dBA or STANDARD (STD) dBA sound output level. All Multitone Strobe models are designed for use with either filtered DC or unfiltered Full-Wave-Rectified (FWR) input voltage. The Multitone Strobe Appliances have separate input terminals for alarm tone activation and strobe activation. Shunt wires are provided to operate both the alarm tone and the strobe simultaneously on a single input circuit (See Wiring Diagram). All inputs are polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). NOTE: All CAUTIONS and WARNINGS are identified by the symbol . All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. WARNING: THE MULTITONE STROBE APPLIANCES MUST BE FIELD SET TO THE DESIRED dBA SOUND OUTPUT LEVEL AND ALARM TONE BEFORE THEY ARE INSTALLED. THIS IS DONE BY PROPERLY INSERTING A JUMPER PLUG AND ADJUSTING A FOUR POSITION SWITCH IN ACCORDANCE WITH THESE INSTRUCTIONS. INCORRECT SETTINGS WILL RESULT IN IMPROPER PERFORMANCE AND MAY DAMAGE THE PRODUCT, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. SPECIFICATIONS: Table 1: UL Listed Models Model Nominal Voltage (VDC) Rated Voltage (VDC) Strobe Candela (CD) Anechoic dBA at 10 Feet Mounting Options MT-12-LS 12 10.5-15.6 15 87-99 MT-12-LSM 12 10.5-15.6 15* 87-99 MT-12-MS 12 10.5-15.6 30 87-99 MT-24-LS 24 20.0-31.0 15 87-99 A,B,C,D MT-24-LSM 24 20.0-31.0 15* 87-99 E,F,G MT-24-MS 24 20.0-31.0 30 87-99 MT-24-IS 24 20.0-31.0 75 87-99 MT4-12-LS 12 10.5-15.6 15 87-99 MT4-12-LSM 12 10.5-15.6 15* 87-99 MT4-12-MS 12 10.5-15.6 30 87-99 MT4-24-LS 24 20.0-31.0 15 87-99 H MT4-24-LSM 24 20.0-31.0 15* 87-99 MT4-24-MS 24 20.0-31.0 30 87-99 MT4-24-IS 24 20.0-31.0 75 87-99 *15cd models are Listed at 15cd and meet 75cd on axis WARNING: CHECK THE MINIMUM AND MAXIMUM OUTPUT OF THE POWER SUPPLY AND STANDBY BATTERY AND SUBTRACT THE VOLTAGE DROP FROM THE CIRCUIT WIRING RESISTANCE TO DETERMINE THE APPLIED VOLTAGE TO THE SIGNALING DEVICE. Copyright 1993-1997, 2000 Wheelock, Inc. All rights reserved.
MT-12-LS: Related Instructions
Description The Wheelock Series E50 Speakers and Speaker Strobes feature high efficiency sound output, with dual voltage (25/70 VRMS) capability and field sel Product reference manual for the Wheelock E50 Speakers. This manual details testing procedures, device operation tips, safety information.
P83567 C Sheet 1 of 10 273 Branchport Avenue Long Branch, NJ 07740 Thank you for using our products. (800) 631-2148 INSTALLATION INSTRUCTIONS www.wheelockinc Device setup guide for the Wheelock Cooper ET70 Speakers. The documentation includes details on firmware updates, setup validation, technical overview.
Technical Manual for the Strobe – XB11 Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept r Manual for safe operation of the Wheelock MEDC XB11 Smoke Alarm. The document highlights operating procedures and hardware setup, firmware updates, application scenarios.
273 Branchport Avenue Long Branch, NJ 07740 (732) 222-6880 INSTALLATION INSTRUCTIONS MODEL TPA-60/TPA-100 PAGING AMPLIFIERS GENERAL APPLICATION INFORMATION Wh User instructions for the Wheelock TPA-100 Amplifier. The manual outlines system configuration and hardware setup, usage procedures, usage tips, application scenarios.
273 Branchport Avenue Long Branch, NJ 07740 (800) 631-2148 Thank you for using our products. www.cooperwheelock.com INSTALLATION INSTRUCTIONS SERIES ET70WP L Complete installation manual for the Wheelock ET70WP-2475C Speakers. This guide offers instructions on performance optimization, hardware instructions, installation support, user preferences.
P84022 F Sheet 1 of 6 273 Branchport Ave. Long Branch, N.J. 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc.com INSTALLATION INSTR Operating handbook for the Wheelock RSS-1215W Smoke Alarm. The guide outlines procedures for compatibility information, diagnostic information, safety information.
Similar Manuals in the Smoke Alarm Category
Complete instruction guide for the Zerio-Plus EDA-R6000 Smoke Alarm. This guide offers instructions on network configuration, usage procedures, troubleshooting tips, service procedures.
Contains vital information on unit operation and installation. Read and retain carefully. If you are just installing this unit this leaflet MUST be given to the Technical operation manual for the Ei Electronics Ei2110 Smoke Alarm. The guide covers usage and cleaning instructions, startup procedures, maintenance, system parameters.
Fire Alarm Systems | FMM‑100SAT2CKEX Explosion‑proof Fire Alarm Manual Station The FMM‑100SAT2CKEX is a high‑quality, die‑cast metal fire alarm manual Installation instructions for the Bosch FMM‑100SAT2CKEX Smoke Alarm. It provides information on safety and maintenance guidelines, user instructions, backup procedures, adjustment procedures.
3.2 Rev: 9/16 95-8636 Addendum HART® Communication with the X5200 UVIR Flame Detector Detailed operating instructions for the Det-Tronics X5200 Security Sensors. It provides technical information on installation procedures, calibration steps, service contacts, product specifications.