5780 Success Dr. Rome, NY 13440 Phone: 1-800-228-9364 Fax: 1-800-232-9364 Email: [email protected] INSTALLATION, OPERATION AND MAINTENANCE MANUAL EMI AMERICASERIES SINGLE-ZONE & MULTI-ZONE CONDENSING UNITS MC4/MH4 MULTI-ZONE MC2/MH2 DUAL-ZONE SCC/SHC SINGLE-ZONE STRAIGHT COOL/HEAT PUMPS Nominal Capacities: 9,000, 12,000, 15, ...

Made in Rome, New York, USA

2 TABLE OF CONTENTS To the Installer and Safety Instructions ........................ 2 Warnings, Controls and Components, ........................ 3 System Options, Installer Supplied Items .................... 3 Low Ambient Option, Site Preparation ....................... 3 Electrical Wiring .... ...

High Efficiency Condensing Units

3 ITEMS FOR CONSIDERATION • Locate the unit as close to the indoor section as possible. Maximum length allowed is 100'. • Avoid high traffic areas and prevailing wind locations. • Surface must be level. • Mount unit above typical snow levels. Ensure free flow of air through the unit. Air must n ...

Made in Rome, New York, USA

4 EMI AMERICASERIES CONDENSING UNIT - COMMON SECTION REFRIGERANT PIPING The standard system will support refrigerant runs to the inside unit of 100' equivalent feet with a 35' rise included. Units are furnished with sweat connections and are equipped with service valves and schrader fittings for cha ...

High Efficiency Condensing Units

5 NOTE: For more information, please visit our web-site at www.enviromaster.com or call 1-800-228-9364. EMI AMERICASERIES CONDENSING UNIT - COMMON SECTION GENERAL RECOMMENDATIONS Do not charge the straight cool units on cold days unless weigh- ing in the charge. The heat pump systems may be charged in ...

Made in Rome, New York, USA

6 SUPERHEAT CHARGING CHART FIELD CHARGING Example: 1. Suction pressure is 65 psi. which equals 38° F on The R-22 Scale of the Low-Side Gauge. 2. Suction line temperature taken at the unit is 70° F. 70° F minus 38° F equals 32° F superheat. 3. Outdoor temperature is 90° F; indoor temperature is 8 ...

High Efficiency Condensing Units

7 PRODUCT DESCRIPTION The AmericaSeries SCC/SHC is an air cooled, high efficiency condensing unit, designed specifically to meet and/or exceed current standards for system energy efficiency ratings. The SCC single zone condensing unit will provide cooling for a single AmericaSeries evaporator of any s ...

Made in Rome, New York, USA

8 SCC/SHC DIMENSIONS & SPECIFICATIONS NOTE: All EMI products are subject to ongoing development programs so design and specifications may change without notice. MOUNTING DIMENSIONS 09-15 18-36 20 5/8” SCC/SHC Electrical Specifications Model# Volts/HZ/PH Fan Motor Compressor Total AMPS Min Volt M.C. ...

High Efficiency Condensing Units

9 18-36 09-15 SCC/SHC DIMENSIONS & SPECIFICATIONS REFRIGERANT CHARGE TABLE FOR SCC/SHC CONDENSER CAPACITY EVAPORATOR PAIRING LINE CHG/FT LINE LENGTH LINE ADJUST FACTORY CHARGE SYSTEM TOTAL SCC SHC SCC SHC 09 CHP 12 FHP 12 WHP 12 TBH 12 CAH 12 CNR 12 .25 OZ. 10 25 50 3 OZ. 6 OZ. 13 OZ. 26.5 OZ. 44 OZ. 29 ...

Made in Rome, New York, USA

10 MC4/MH4 MULTI-ZONE High Efficiency Condensing Unit Limited Range Heat Pump PRODUCT DESCRIPTION The America Series high efficiency MC4 Multi-Zone Air Conditioners and MH4 Heat Pumps may contain 2, 3, or 4 compressors and low voltage wiring circuits for connection to 2, 3, or 4 indoor evaporators. E ...