Viessmann VITOTRONIC 300-K Installation And Service Instructions Manual
File Specifications
| Brand: | Viessmann |
| Category: | Control Unit |
| Model: | VITOTRONIC 300-K (Installation And Service Instructions Manual), pr8SyaA8FOzSc |
| File Info: | Adobe Acrobat PDF (DjVu) |
| File Size: | — |
| Pages: | 164 pages |
Download PDF
Download Viessmann VITOTRONIC 300-K Manual (164 pages)Read Online:
Read the Viessmann VITOTRONIC 300-K Installation And Service Instructions Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.
Key Pages of Document
5793 309 - 05
Vitotronic 100, GC1B / Vitotronic 300-K, MW1B Installation and Service Installation Examples System Example 1 Multi boiler system: Boiler with Therm-Control Note: This scheme is a basic example without shut-off devices or safety equipment. This does not replace the need for local engineering. ...
Vitotronic 100, GC1B / Vitotronic 300-K, MW1B Installation and Service
5793 309 - 05 110 Cascade Control of the Vitotronic 300-K Cascading Layouts Boilers connected in parallel H Without and with supply temperature sensor. H Set code “3B:0” or “3B:1” in the “Cascade” group. H The cascade control specifies the set boiler water temperature for all currently active boilers. Every boiler control unit regulates to the specified set value. The following control strategies are available: H Condensing strategy (see page 111) H Conventional strategy 1 (see page 111) H Conventional strategy ...
5793 309 - 05
Vitotronic 100, GC1B / Vitotronic 300-K, MW1B Installation and Service Connecting Actuators Available connections gS A1 Motor for 3-way mixing valve, primary store system gS M2 For heating circuit 2 gS M3 For heating circuit 3 Rated voltage: 120V~ Rated current Max.: 0.1A~ Motor runtime for 3-way mixing valve: 10 to 255 sec, adjustable via coding addresses “6A” in the”DHW”group, “C3” in the HC2 group and “C3” in the HC3 group. 1. Disconnect power to control. 2. Install 120V or 24V valve adaptor on DIN rail inside connection enclosure. 3. Insert the plug gS ...
Vitotronic 100, GC1B / Vitotronic 300-K, MW1B Installation and Service
5793 309 - 05 26 Installation Examples System Example 3 (continued) Equipment required Pos. Description 1 Boiler I 2 Boiler water temperature sensor KTS 3 Vitotronic 100 4 Vitotronic 300-K 5 Outside temperature sensor ATS 6 Supply temperature sensor, common heating flow VTS as - contact temperature sensor (standard delivery for Vitotronic 300-K) or - immersion temperature sensor 7 3-way mixing valve 8 Temperature sensor T1 as - contact temperature sensor or - immersion temperature sensor 9 Boiler circuit pump qP B ...
Vitotronic 100, GC1B / Vitotronic 300-K, MW1B Installation and Service
5793 309 - 05 150 “Heating Circuit 1”, “Heating Circuit 2”, “Heating Circuit 3” Group (continued) Coding 2, Vitotronic 300-K Coding in the factory set condition Possible change D8:0 No heating program changeover via extension EA1 D8:1 Heating program changeover via input DE1 at extension EA1. D8:2 Heating program changeover via input DE2 at extension EA1. D8:3 Heating program changeover via input DE3 at extension EA1. E1:1 With remote control: Set day temperature adjustable at the remote control unit from 50 to ...
Vitotronic 100, GC1B / Vitotronic 300-K, MW1B Installation and Service
5793 309 - 05 98 1. Press OK and simultaneously for approx. 4 sec. 2. “Diagnosis” 3. “Brief scan”. 4. Press OK. The display shows 9 lines with 6 fields each. Service Scans, Vitotronic 300-K For an explanation of the relevant values in the individual lines, see the following table: Line (brief scan) Field 1 2 3 4 5 6 1: System schemes 01 to 10 Control unit software version Programming unit software version 2: 2 0 0 0 Appliance identification ZE-ID 3: 0 0 Number of KM BUS participants Software version Solar control m ...
Vitotronic 100, GC1B / Vitotronic 300-K, MW1B Installation and Service
5793 309 - 05 36 Installation Examples System Example 4 (continued) Equipment required Pos. Description tE KM BUS distributor, for several KM BUS participants zP Extension EA1 zQ 1 switching output (floating changeover contact): - Switching a feed pump to a substation - Signalling reduced mode for a heating circuit zW 1 analog input (0 – 10V): - Specifying the set system supply temperature zE 3 digital inputs: - External heating program changeover, separately adjustable for heating circuits 1 to 3 - External demand ...
Table of Contents
5 Page 5793 309 - 05 Vitotronic 100, GC1B / Vitotronic 300-K, MW1B Installation and Service Service Scans, Vitotronic 300-K Troubleshooting, Vitotronic 100 Troubleshooting, Vitotronic 300-K Function Description Coding 1, Vitotronic 100 Coding 2, Vitotronic 100 Coding 1, Vitotronic 300-K Coding 2, Vitotronic 300-K Wiring, Vitotronic 100 Wiring, Vitotronic 300-K Components Parts Lists Specification Calling up Service Menu............................................97 Scanning Operating Data...........................................97 Brief Scan................................. ...
Viessmann VITOTRONIC 300-K user guide recommended for: B2TB004, Vitotrol 350, VITOBLOC 200, Vitosol-F, Solar-Divicon.
⚠️ Download Safety
The Control Unit Installation and service instructions manual (164 pages) is completely safe to download (last scan date: 26/01/2026).
Related PDF Instructions for Viessmann VITOTRONIC 300-K:
-
Viessmann Vitodens 300 Boiler Installation instructions manual
Vitodens 30020 -
Viessmann Vitoclima 200-C Chiller Service instructions manual
Vitoclima 200-C60 -
Viessmann VITOTROL 100 Temperature Controller Operating instructions manual
VITOTROL 10024 -
Viessmann VIVOTRONIC 050 HK3W Control Unit Operating instructions manual
VIVOTRONIC 050 HK3W30 -
Viessmann Vitodens 100-W B1HA Boiler Application manual
Vitodens 100-W B1HA48 -
Viessmann Vitodens 200-W System Heater Start-up/service instructions
Vitodens 200-W System81
Control Unit Equipment: Frequently Requested
-
KEB COMBIVERT F5 DC Drives
02.03.2026User handbook for the KEB COMBIVERT F5 DC Drives. It explains maintenance and power requirements, firmware installation, testing procedures.COMBIVERT F5, 30 -
Comparato Diamant SMART PRO Control Unit
25.02.2026Device technical manual for the Comparato Diamant SMART PRO Control Unit. It details troubleshooting tips and operating conditions, installation guides, system checks.Diamant SMART PRO, 20 -
Honeywell BCU 460 Control Unit
21.02.2026Manual for safe operation of the Honeywell BCU 460 Control Unit. This guide includes usage recommendations, product handling, testing procedures.BCU 460, 145 -
GEM 0324 Control Unit
21.04.2026User setup guide for the GEM 0324 Control Unit. This manual offers stepwise instructions for usage examples, software installation, safety protocols.0324, 21 -
Cradlepoint MC20BT Control Unit
26.06.2026User operation guide for the Cradlepoint MC20BT Control Unit. The manual provides step-by-step instructions on power requirements, menu navigation, installation steps.MC20BT, 4 -
Jafar 8890 Control Unit
09.04.2026Professional user manual for the Jafar 8890 Control Unit. It includes usage scenarios and safety guidelines, troubleshooting tips, software installation, service contacts.8890, 8
Have some Questions about Viessmann VITOTRONIC 300-K Device?
Get valuable and actionable advices from other Viessmann VITOTRONIC 300-K device users. Describe your problem or question, regarding the using of VITOTRONIC 300-K, in as much detail as possible, and other users will be able to answer you.