televac_an3018 rev - Page 1 of 12 Televac Application Note 3018 MX200 EthernetIP Vacuum Controller Setup and Troubleshooting Guide for EthernetIP Option 2 Contents 1 Description....................................................................................................................................................... 1 2 Windows™ 7 Operating Systems Configuration ................................................................................................ 2 3 Windows™ 10 Operating Systems Configuration ............................ ...

© 2017 The Fredericks Company | www.frederickscompany.com | [email protected] | +1 215 947 2500

televac_an3018 rev - Page 2 of 12 2 Windows™ 7 Operating Systems Configuration 2.1 Configuring the IP Address 2.1.1 Connect the MX200 EthernetIP port on the back of the unit to your computer. 2.1.2 Open the Network and Sharing Center in the Control Panel and verify that an Ethernet connection is being made. If there is no connection, check the cable and reinsert the Ethernet cable into the adapter on the computer. 2.1.3 Select the Ethernet Local Area Connection. ...

© 2017 The Fredericks Company | www.frederickscompany.com | [email protected] | +1 215 947 2500

televac_an3018 rev - Page 3 of 12 2.1.4 In the Local Area Connection Status panel, select Properties. 2.1.5 In the Local Area Connection Properties panel, select Internet Protocol Version 4 (TCP/IPv4) and select Properties. ...

© 2017 The Fredericks Company | www.frederickscompany.com | [email protected] | +1 215 947 2500

televac_an3018 rev - Page 4 of 12 2.1.6 In the Internet Protocol Version 4 Properties panel, mark down the current settings to revert back to later. The local machine will need to be configured to the module to adjust the settings, but will need to be brought back onto the local network in order to communicate properly when finished. In this example, the local machine has an IPv4 address of 149.174.211.52 with a subnet mask of 255.255.0.0 and a default gateway of 149.174.211.2. 2.1.7 Adjust the settings of the computer to an IP address of 192.168. ...

© 2017 The Fredericks Company | www.frederickscompany.com | [email protected] | +1 215 947 2500

televac_an3018 rev - Page 5 of 12 2.1.8 The computer and unit should now be on the same local network. Open a browser, and enter the IP address of the unit (192.168.0.8) into the search bar. When prompted, enter the username and password (default Admin:admin). 2.1.9 The web page hosted by the module should appear. Select the Configuration tab on the left. 2.1.10 Change the IP address and subnet mask to the desired configuration (see step 2.1.6 for the network configuration). In this example, step 2.1.6 showed that the network needed is 149.174.211 ...

© 2017 The Fredericks Company | www.frederickscompany.com | [email protected] | +1 215 947 2500

televac_an3018 rev - Page 6 of 12 2.1.11 The unit is now configured to the network. Follow steps 2.1.2 to 2.1.7 to change the local computer back to the original settings (original settings are the noted settings in step 2.1.6). 2.2 Verifying the Setup 2.2.1 After the IP address and subnet mask are configured, network connectivity can be verified through the PLC or through the web functionality. To verify through the web functionality, type the IP address into address bar in the browser and enter the username and password (default Admin:admin). 2. ...

© 2017 The Fredericks Company | www.frederickscompany.com | [email protected] | +1 215 947 2500

televac_an3018 rev - Page 7 of 12 3 Windows™ 10 Operating Systems Configuration 3.1 Configuring the IP Address 3.1.1 Connect the MX200 EthernetIP port on the back of the unit to your computer. 3.1.2 Open the Network and Sharing Center in the Control Panel and verify that an Ethernet connection is being made. If there is no connection, check the cable and reinsert the Ethernet cable into the adapter on the computer. 3.1.3 Select the Ethernet Connection. ...

© 2017 The Fredericks Company | www.frederickscompany.com | [email protected] | +1 215 947 2500

televac_an3018 rev - Page 8 of 12 3.1.4 In the Ethernet Status panel, select Properties. 3.1.5 In the Ethernet Properties panel, select Internet Protocol Version 4 (TCP/IPv4) and select Properties. ...

© 2017 The Fredericks Company | www.frederickscompany.com | [email protected] | +1 215 947 2500

televac_an3018 rev - Page 9 of 12 3.1.6 In the Internet Protocol Version 4 Properties panel, mark down the current settings to revert back to later. The local machine will need to be configured to the module to adjust the settings, but will need to be brought back onto the local network in order to communicate properly when finished. In this example, the local machine has an IPv4 address of 149.174.211.116 with a subnet mask of 255.255.0.0 and a default gateway of 149.174.211.2. 3.1.7 Adjust the settings of the computer to an IP address of 192.168 ...

© 2017 The Fredericks Company | www.frederickscompany.com | [email protected] | +1 215 947 2500

televac_an3018 rev - Page 10 of 12 3.1.8 The computer and unit should now be on the same local network. Open a browser, and enter the IP address of the unit (192.168.0.8) into the search bar. When prompted, enter the username and password (default Admin:admin). 3.1.9 The web page hosted by the module should appear. Select the Configuration tab on the left. 3.1.10 Change the IP address and subnet mask to the desired configuration (see step 3.1.6 for the network configuration). In this example, step 3.1.6 showed that the network needed is 149.174.21 ...

© 2017 The Fredericks Company | www.frederickscompany.com | [email protected] | +1 215 947 2500

televac_an3018 rev - Page 11 of 12 3.1.11 The unit is now configured to the network. Follow steps 3.1.2 to 3.1.7 to change the local computer back to the original settings (original settings are the noted settings in step 3.1.6). 3.2 Verifying the Setup 3.2.1 After the IP address and subnet mask are configured, network connectivity can be verified through the PLC or through the web functionality. To verify through the web functionality, type the IP address into address bar in the browser and enter the username and password (default Admin:admin). 3 ...

© 2017 The Fredericks Company | www.frederickscompany.com | [email protected] | +1 215 947 2500

televac_an3018 rev - Page 12 of 12 4 Contact Us Please feel free to contact us with any questions: The Fredericks Company - Televac 2400 Philmont Avenue Huntingdon Valley, PA 19006, USA Web: www.frederickscompany.com Email: [email protected] Phone: +1 215 947 2500 ...

Controller PDF Instructions

Lamp Controller
Savant Lamp Controller
02.08.2026 3 pages

LAMP CONTROL QUICK START GUIDE Device setup manual for the Savant Lamp Controller Controller. It provides information on safety and adjustment procedures, performance guidelines, repair references.

FMR-7033
Bosch FMR-7033
06.05.2026 8 pages

FMR-7033 EN Installation Instructions Addressable Fire System Controller User and installation guide for the Bosch FMR-7033 Controller. It explains configuration options and technical overview, usage procedures, support details, device reset instructions.

AAEON AHP-1154
Asus AAEON AHP-1154
13.07.2026 78 pages

Last Updated: February 24, 2020 AHP-1154 Industrial HMI Touch Panel User’s Manual 3rd Ed Complete service manual for the Asus AAEON AHP-1154 Controller. This guide explains the features and network configuration, setup instructions, device overview, daily usage.

Link Hydronic Controller
Danfoss Link Hydronic Controller
01.06.2026 13 pages

Danfoss heating solutions MaKing MoDeRn liVing PossiBle Installation Guide Danfoss Link™ Hydronic Controller Operation instructions for the Danfoss Link Hydronic Controller Controller. It details operating modes and dimensions and layout, warranty information, supported accessories.