Onicon D-100 Installation Manual

File Specifications

Brand: Onicon
Category: Measuring Instruments
Model: D-100 (Installation Manual), prpC3Gus9qbbY
File Type: PDF
File Size: —
Pages: 33 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (33 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 17/04/2026).

Read Online

Read the Onicon D-100 Installation Manual online using the built-in PDF viewer.

Key Pages of Document

D-100 FLOW DISPLAY

BACnet Network Interface Installation Guide 11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 www.onicon.com • [email protected] 03-18 0635-11 / 18341 BACnet ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 2 ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 3 TABLE OF CONTENTS 1.0 INTRODUCTION ..................................................................................................5 1.1 PURPOSE OF THIS GUIDE .......................................................................5 1.2 TYPICAL ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 4 ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 5 D-100 SCROLL RESET PROGRAM ONICON 3864 Steam Building Domestic Water Supply Flow rate and total data to Data Acquisition System or Building Control System 120VAC or 24VAC Input Voltage 1.3 SPECIFICATIONS BACnet NETWORK INTERFACE MS/TP RS485 ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 6 1.4 NETWORK SIGNAL CONNECTIONS 1.4.1 BACnet MS/TP BACnet MS/TP, 2-wire (half-duplex) serial output connections are connected to terminal T1 as shown. Do not exceed 4.4 in-lb (0.5 Nm) of torque when tightening. Terminal T1 Do not connect shields ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 7 1.4.2 BACnet/IP BACnet/IP, Base 10T output connections are made as shown. Requires Base 10T cable and RJ45 connector. ! CAUTION Only qualified service personnel should make connections between the D-100 Flow Display and the user’s external equ ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 8 1.4.3 Optional Network Interface With Isolated Digital Pulse Input (Di3) The D-100-BACnet Display can be provided with an digital input pulse for totalizing pulse outputs from external devices such as water or gas meters. Pulses are accumulated ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 9 Powered Pulse: This type of output refers to a pulse which has an associated voltage with it (see Fig. 2). Set the selector switch, S1 to Pwrd Pulse. The allowable voltage range is 5-24 VDC. The input impedance is set at the factory to be 11 KOH ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 10 Open Collector Sinking or Dry Contact: This type of output refers to an open collector switch configured in a current sinking arrangement or a dry contact switch (see Fig. 4 and 5). Set the selector switch, S1 to Sink. In either case, the switc ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 11 1.5 BACnet MS/TP BAUD RATE, BIASING & TERMINATION 1.5.1 Baud Rate Every ONICON D-100 is individually programmed at the factory with application specific data provided by the customer during the process of ordering the display, and this normally ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 12 1.5.2 Biasing and Termination The ONICON D-100 does not provide biasing voltage to the RS485 network. A jumper selectable 120W termination resistor is provided as show below. The termination resistor should only be used when the display is inst ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 13 STEP ACTION REACTION COMMENT 0 Obtain MAC address & device instance number from the network administrator. None. The MAC address is a three digit number from 001 – 254. The device instance number can be anything from 0 – 4,194,303. 1 With t ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 14 1.6.2 Changing the IP Address Changing the IP address requires the use of RUInet utility software and a PC with an Ethernet card and an available port. Assuming the display is programmed with the default address (192.168.1.24) the host PC must ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 15 5. From the Edit IP Address Settings menu (shown below) select option 1. Please note that the default subnet mask is 255.255.255.0 and should not be changed unless necessary. 6. Enter the new IP address as shown below and press enter. ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 16 7. The following message will appear. 8. When the address change is complete, the following message will appear. You must cycle power to the D-100 for the change to take effect. ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 17 1.6.3 Changing the Gateway Address Changing the gateway address requires the use of RUInet utility software and a PC with an Ethernet card and an available port. Assuming the display is programmed with the default address (192.168.1.24) the hos ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 18 5. From the Edit IP Address Settings menu (shown below) select option 3. 6. Enter the new gateway address as shown below and press enter. ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 19 7. The following message will appear. 8. When the address change is complete, the following message will appear. You must cycle power to the D-100 for the change to take effect. ...

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

D-100 Display Module BACnet Installation and Operation Guide 03/18 - 0635-11 / 18341 Page 20 SECTION 2.0: BACnet PICS AND OBJECTS • 0636 D-100 Network Interface Module BACnet/IP Driver Protocol Implementation Conformance Statement (PICS) BACnet Protocol Date: January 1, 2010 Vendor Name: ONICON Incorporated Product Name: D-100-BAC Ne ...

Related Devices for Onicon D-100:

F-3100 Series
Onicon F-3100 Series
28.03.2026 42 pages

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 www.onicon.com • [email protected] F-3100 SERIES Inline E Maintenance instructions for the Onicon F-3100 Series Measuring Instruments. It describes operating procedures and firmware updates, device features, safety features.

System-10 BTU Meter
Onicon System-10 BTU Meter
02.06.2026 48 pages

ONICON Flow and Energy Measurement SYSTEM-10 SYSTEM-10 BTU Meter BTU Meter Installation and Operation Guide Installation and Operation Guide DOC-0002341 Rev.C User instruction booklet for the Onicon System-10 BTU Meter Measuring Instruments. The document contains service instructions, operating modes, installation guides, connectivity setup.

D-100
Onicon D-100
03.09.2026 62 pages

D-100 FLOW DISPLAY with NETWORK INTERFACE Installation and Operation Guide With BACnet Network Interface Installation Guide 1500 North Belcher Road, Clearwater, Operation guide for the Onicon D-100 Measuring Instruments. It provides detailed operation instructions and software updates, network setup, maintenance guidelines, device operation tips.

Fox Thermal FT4X
Onicon Fox Thermal FT4X
11.04.2026 128 pages

106796 Rev D Model FT4X Fox Thermal www.foxthermal.com | 399 Reservation Road Marina, CA. 93933 THERMAL MASS FLOW METER & TEMPERATURE TRANSMITTER Precision Product operation manual for the Onicon Fox Thermal FT4X Measuring Instruments. The guide provides instructions on operating modes, detailing setup, service contacts, user settings.

F-5000
Onicon F-5000
23.07.2026 28 pages

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727)442-5699 www.onicon.com • [email protected] F-5000 View Software In Operational manual for the Onicon F-5000 Measuring Instruments. This documentation details installation guides, system configuration, daily usage.

F-4600 Series
Onicon F-4600 Series
28.08.2026 37 pages

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 www.onicon.com • [email protected] F-4600 INLINE ULTRASON Complete operating guide for the Onicon F-4600 Series Measuring Instruments. It explains configuration options and system parameters, product specifications, firmware installation, software installation.

Fox Thermal FT2A
Onicon Fox Thermal FT2A
13.04.2026 2 pages

MODEL FT2A FLOW METER TROUBLESHOOTING GUIDE Rev. B Precision Mass Flow Measurement An ONICON Brand Phone: (831) 384-4300 • Fax: (831) 337-5786 • www.foxthe Technical setup manual for the Onicon Fox Thermal FT2A Measuring Instruments. It explains operation, maintenance, and replacement parts, software installation, software updates, internal layout.

F-5500
Onicon F-5500
20.04.2026 96 pages

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 www.onicon.com • [email protected] F-5500 Insertion and I Product usage guide for the Onicon F-5500 Kitchen Appliances. This manual covers troubleshooting guides, device reset instructions, functional overview.

Measuring Instruments: Frequently Requested PDF Instructions

AL 5
DVA AL 5
12.04.2026 60 pages

D.M. 174/2004 RIF. 02/18AL AL 5 AL 8 AL 12 Manuale d’istruzioni Instruction Manual Notice d’Utilisation Handbuch Manual de Istrucciones Volumetrico Volumetr Operating handbook for the DVA AL 5 Measuring Instruments. This documentation provides step-by-step guidance on shutdown procedures, device calibration, wiring setup.

DME D300T2
LOVATO ELECTRIC DME D300T2
22.03.2026 7 pages

Doc: I306PLGB0411 20/04/2011 s. 1 / 7 PL DME D300T2 DME D300T2 Licznik Detailed operating instructions for the LOVATO ELECTRIC DME D300T2 Measuring Instruments. This manual covers operational guidelines, safety information, dimensions and layout, technical specifications.

UniTire
Unipro UniTire
25.05.2026 28 pages

UniTire Pressure Gauge User Guide Device user manual for the Unipro UniTire Measuring Instruments. This guide includes detailed instructions for installation support, safety information, security instructions.

980
Quantum Data 980
12.04.2026 198 pages

980 User Guide Rev. B29 Page 1 August 5, 2011 980 Protocol Analyzer User Guide Rev: B29 Installation and operation manual for the Quantum Data 980 Measuring Instruments. It provides detailed operation instructions and software updates, operating instructions, device overview, installation guides.