SDC E4KP ENTRYCHECK Security Door Controls

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • Fax: (805) 494-8861 www.sdcsecurity.com • E-mail: [email protected] The E4KP EntryCheck™ is a fully self-contained proximity access control reader. It is keypad programmable and does not require software or a PC connection. INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK™ P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C

P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C 10-09 Page 2

FACTORY DEFAULTS System Setup Password…………………………………………………………………...…………………111111 (6 digits) Door Open Password...…………………………………………………………………………...……………1234 (4 digits) Door Open Mode…………………………………………

SDC E4KP ENTRYCHECK Entering Programming Mode

Before ANY cards have been enrolled, Enter the System Setup Password + # {Alternating Red & Green LED} NOTE: Default System Setup Password is 111111 After a card or card number has been enrolled, (First card programmed is your programming card) Enter the System Setup Password + # {Fast flashing Red} Present first card programmed (programming card OR (Enter programming card number + #) {Alternating Red & Green L

Set Alarm Relay Time (Default = 5 sec)

Enter Programming Mode {Alternating Red & Green LED} Press 2 + [00-99 seconds] + # {Alternating Red & Green LED} Press # to exit Programming {Solid Red LED} NOTE: The Alarm Relay is used for Forced Door & Door Prop alarms. 00 = Non-stop alarm – Reset by using a valid card. Enable Forced Door Alarm Relay (Default = Force Door Disabled) Enter Programming Mode {Alternating Red & Green LED} To en

CONTROLLER RELAY MODULE –

MODEL E5RM +12V GND CLOCK DATA +- ACCESS CONTROLLER K3 FUNCTION SETTING FUNCTION DURESS/SHUNT GUARD PATROL 1 2 3 ON OFF OFF ON ON OFF OFF OFF OFF MODEL : E5RM S/N : 12345678 K3 ALARM STRIKE DOOR SENSOR EXIT BUTTON INPUT DC12V ON 1 2 3 PROGRAMMING OPTIONS (CONTINUED) SPECIFICATIONS Keypad – Model E4KP Operating Voltage: 10V – 15V DC Power Consumption: 120mA Max @ 12VDC Frequency: 125KHz Read Range: Up to

CONTROLLER RELAY MODULE

NOT USED RED BLK BRN ORG YEL GRN BLU YEL GRN BLU YEL GRN BLU +- 12 VDC LOCK OUTPUT ALARM OUTPUT AUX. OUTPUT (DIP SW SELECTABLE) C NC NO C NC NO C NC NO Request -to-Exit Door Status J2 J1 RED BLK BRN ORG YEL GRN BLU YEL GRN BLU YEL GRN BLU (+) R