SDC E4KP ENTRYCHECK Operating Instructions Manual
| Brand: | SDC |
| Category: | IP Access Controllers |
| Model: | E4KP ENTRYCHECK (Operating Instructions Manual) |
| File Type: | |
| File Size: | — |
| Pages: | 6 |
Text of SDC E4KP ENTRYCHECK Operating Instructions Manual
SDC E4KP ENTRYCHECK Security Door Controls
801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • Fax: (805) 494-8861
www.sdcsecurity.com • E-mail: [email protected]
The E4KP EntryCheck™ is a fully self-contained proximity access control reader. It is keypad programmable and
does not require software or a PC connection.
INSTALLATION/PROGRAMMING INSTRUCTIONS
E4KP ENTRYCHECK™
P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C
P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C 10-09 Page 2
FACTORY DEFAULTS
System Setup Password…………………………………………………………………...…………………111111 (6 digits)
Door Open Password...…………………………………………………………………………...……………1234 (4 digits)
Door Open Mode…………………………………………
SDC E4KP ENTRYCHECK Entering Programming Mode
Before ANY cards have been enrolled,
Enter the System Setup Password + # {Alternating Red & Green LED}
NOTE: Default System Setup Password is 111111
After a card or card number has been enrolled, (First card programmed is your programming card)
Enter the System Setup Password + # {Fast flashing Red}
Present first card programmed (programming card OR (Enter programming card number + #) {Alternating Red & Green
L
Set Alarm Relay Time (Default = 5 sec)
Enter Programming Mode {Alternating Red & Green LED}
Press 2 + [00-99 seconds] + # {Alternating Red & Green LED}
Press # to exit Programming {Solid Red LED}
NOTE: The Alarm Relay is used for Forced Door & Door Prop alarms. 00 = Non-stop alarm – Reset by using a valid card.
Enable Forced Door Alarm Relay (Default = Force Door Disabled)
Enter Programming Mode {Alternating Red & Green LED}
To en
CONTROLLER RELAY MODULE –
MODEL E5RM
+12V
GND
CLOCK
DATA
+-
ACCESS
CONTROLLER
K3 FUNCTION SETTING
FUNCTION
DURESS/SHUNT
GUARD
PATROL
1
2
3
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
MODEL : E5RM
S/N : 12345678
K3
ALARM
STRIKE
DOOR SENSOR
EXIT BUTTON
INPUT DC12V
ON
1 2 3
PROGRAMMING OPTIONS (CONTINUED)
SPECIFICATIONS
Keypad – Model E4KP
Operating Voltage:
10V – 15V DC
Power Consumption:
120mA Max @ 12VDC
Frequency:
125KHz
Read Range:
Up to
CONTROLLER RELAY MODULE
NOT
USED
RED
BLK
BRN
ORG
YEL
GRN
BLU
YEL
GRN
BLU
YEL
GRN
BLU
+-
12 VDC
LOCK
OUTPUT
ALARM
OUTPUT
AUX. OUTPUT
(DIP SW SELECTABLE)
C
NC
NO
C
NC
NO
C
NC
NO
Request -to-Exit
Door Status
J2
J1
RED
BLK
BRN
ORG
YEL
GRN
BLU
YEL
GRN
BLU
YEL
GRN
BLU
(+)
R