Text of SDC EntryCheck 920 Installation Instructions Manual
The EntryCheck™ 920 Indoor/Outdoor Keypad is a surface-mount digital
keyless entry system designed for access control applications. The backlit
keys are bright and easy-to-read. A heavy cast vandal resistant housing
design with mounting plate allows the 920 to be mounted on a rugged
surface or on a standard single-gang electrical box.
The 920 has a capacity of 500 users. Users can be assigned to use 4 to 6
digit PIN codes. An authenticated access c
SDC EntryCheck 920 TO POWER SUPPLY
KEYPAD POWER
12 or 24 VOLTS
AC OR DC
}
+
-
RED
BLACK
NC
AUXILIARY RELAY
2 AMPS @ 28VDC MAX
}
NO
COM
ORANGE
WHITE
BLACK
MAIN RELAY
5 AMPS @ 28VDC MAX
}
NO
COM
NC
ORANGE
WHITE
YELLOW
P:\INST INSTRUCTIONS\ACCESS CONTROLS\INST-920 Rev G 04-21 Page 2
CAUTION
IF THE UNIT IS AC POWERED, MAKE SURE
THAT THE SECONDARY OF THE SYSTEM IS
ISOLATED FROM EARTH GROUND
!
!
Fig. 2 Wiring Pigtail Color Code
Security Door Controls
Test your n
SDC EntryCheck 920 P:\INST INSTRUCTIONS\ACCESS CONTROLS\INST-920 Rev G 04-21 Page 3
KEYPAD WIRING
See Fig. 3 for an example of a basic door installation. The keypad is
mounted adjacent to the door. An electric door strike is mounted in the
door jamb to release the door lock. An optional door contact switch is
mounted on top of the door jamb for detecting when the door is open.
Use the following steps to wire the keypad. Refer to the wiring diagram
shown
SDC EntryCheck 920 P:\INST INSTRUCTIONS\ACCESS CONTROLS\INST-920 Rev G 04-21 Page 4
FACTORY DEFAULTS
Master Programming Code………..………………….….…...123456
Entry Code Length……………………………………….……..4 digits
Request-to-exit Output Relay………………………..........No Output
Alarm Shunt Output….………………………………….........Disabled
Forced Entry Output…………………………….
P:\INST INSTRUCTIONS\ACCESS CONTROLS\INST-920 Rev G 04-21 Page 5
Configure Sense Input Default: INHIBIT
The Sense Input (gray wire) can be programmed for either
DOOR SENSE or INHIBIT.
Press: 10 # Input #
Input=0 for Door Sense; =1 for Inhibit
When programmed for DOOR SENSE, if an open condition on
the input occurs before access is granted (with an entry code or
with the request-to-enter input) a FORCED ENT
P:\INST INSTRUCTIONS\ACCESS CONTROLS\INST-920 Rev G 04-21 Page 6
Beep Sounds During Auxiliary Relay Default: No
Selects whether or not the keypad beeps during Auxiliary Relay
activation.
Press: 42 # Sound #
Sound=1 for Yes, =0 for No
Beep Sounds During Output #3 Default: No
Selects whether or not the keypad beeps during Output #3
activation.
Press: 43 # Sound #
Sound=1 for Yes, =0 for No
Be
MOUNTING TO SINGLE GANG
RECESSED OUTLET BOX
2X
Mount
at slots
4X Mount at holes
With supplied
screws and hole
expansion anchors
SURFACE MOUNT
P:\INST INSTRUCTIONS\ACCESS CONTROLS\INST-920 Rev G 04-21 Page 7
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011