1 x isolated duplex RS-232 with DTR

1 x isolated TX-only RS-232 Isolation >500V from indicator to module Power Supply Internal Baud rate1 2400, 4800, 9600, 19200, 38400, 57600 Parity bit1 None, Even, Odd Data bits1 7, 8 Stop Bits1 1, 2 DTR1 OFF, ON Note 1: Instrument may not support all options. Interface Diagram: Example Use: Module Connections M4201 RS-232/232 Comms

The indicator should be switched OFF before installing or removing this device.

Modules are configured using the indicator setup. Setup can be done via the indicator keypad or the viewer program. An overview of setup is given below; see the indicator Quick Start or Reference manuals for detailed setup information. The indicator provides configuration checking capabilities for the M4201. This is found in the H.WARE setup menu. S