Rinstrum 400 Series Reference Manual
Text of Rinstrum 400 Series Reference Manual
All Rights Reserved. No part of this document may be
copied, reproduced, republished, uploaded, posted,
transmitted, distributed, stored in or introduced into a
retrieval system in any form, or by any means (electronic,
mechanical, photocopying, recording or otherwise)
whatsoever without prior written permission of Rinstrum
Pty Ltd.
Disclaimer
Rinstrum Pty Ltd reserves the right to make changes to
the products contained in this manual in order to
Reference Manual Rev 1.40
004R-623-140
Page 1
Table of Contents
1.
INTRODUCTION ................................................................................................................... 5
1.1.
Overview .................................................................................................................... 5
1.2.
Document Conventions .............................................................................................. 6
2.
SPE
Rinstrum 400 Series Reference Manual Rev 1.31
Page 2
004R-623-140
6.
CONFIGURATION............................................................................................................... 35
6.1.
General Setup Information ........................................................................................ 35
6.2.
Calibration Counter................................................................................................... 35
6.3.
Passcodes ..................
Reference Manual Rev 1.40 004R-623-140
Page 3
8.7.2.
AUTO.n (Automatic Output Configuration) ................................................ 54
8.8.
PRINT (Printouts) ..................................................................................................... 55
8.8.1.
NUM (Number of printouts) ....................................................................... 55
8.8.2.
HEADER (Print header) ..................................................
Reference Manual Rev 1.31 Page 4
004R-623-140
14.3. Analogue Weight Transmission ................................................................................ 86
15.
APPENDIX 1: DIMENSIONS ............................................................................................... 87
15.1. Dimensions .............................................................................................................. 87
15.2. Legal Sealing Details ..........
Reference Manual Rev 1.40 004R-623-140
Page 5
1.
Introduction
1.1.
Overview
This precision digital summing indicator can sum up to nine slave indicators from either the
R300 or R400 range. These can be connected together on a multi-drop serial RS485 bus or
RS232 ring network. The summing indicator polls each of the slave units summing all of the
weight readings and displays the resulting total weight. The setpointing, printing facilities, and
accessory mod
Reference Manual Rev 1.31 Page 6
004R-623-140
The instrument can support different software applications depending on the functionality
required. This manual covers the K481 summing indicator. Please refer to the relevant manual
for the slave indicators.
1.2.
Document Conventions
The following document conventions (typographical) are used throughout this Reference
Manual.
Bold Text Bold text denotes words and phrases to note.
denotes a Keypad k
Reference Manual Rev 1.40 004R-623-140
Page 7
2.
Specifications
Performance
Operating
Environment
Temperature: –10 to +50C ambient
Humidity: <90% non-condensing
Storage: –20 to +50C ambient
IP55 when panel mounted or with rear boot (otherwise IP40)
Case Materials
ABS, Silicon Rubber, Nylon, Acrylic (no halogen used)
Packing Weights
Basic Indicator: 0.6kg
Digital
Display
LCD with 4 alpha-numeric displays and LED backlighting:
• Primary display:
Reference Manual Rev 1.31 Page 8
004R-623-140
Software
V1
V2
Summing Slaves
9
9
Summing Subtotals
4
4
Input/Outputs
32
32
Setpoints
8
16
External Keys
8
8
Assignable Functions
8
8
Analogue Output
1
1
Communication 1xRS232 Duplex and 1xRS485 TX only
✓
✓
Additional Communications Modules
✓
✓
Products
10
250
Automatic Output
2
2
Automatic Output – Custom format
✓
✓
Single Automatic Output
✓
✓
Printouts
2
2
Custom Printouts
✓
✓
Report Pri
Reference Manual Rev 1.40 004R-623-140
Page 9
3.
Installation
3.1.
Introduction
The following steps are required to set up the indicator.
• Inspect indicator to ensure good condition.
• Use connection diagrams to wire up slave indicator serial connections, power and auxiliary
cables as required.
• Use the drill hole template provided for hole locations.
• Connect power to indicator and press key to turn the instrument ON.
• Refer to the S
Reference Manual Rev 1.31 Page 10
004R-623-140
3.6.
Cable Connections
All cable connections are made to the rear of the instrument using pluggable screw terminals.
It is not necessary to tin the ends of the wires with solder or to add crimp ferrules to the wires,
however, these techniques are compatible with the terminals.
Figure 2: Cable Connections
3.7.
DC Power (DC PWR +, DC PWR –)
The DC supply need not be regulated, provided that it is free of exces
Reference Manual Rev 1.40 004R-623-140
Page 11
Summing R320 Indicators using RS232 Ring Network
3.9.
Load Cell Connection
As this is a summing indicator, the loadcell connection is not required and should not be
connected.
3.10. Auxiliary Connections
This section provides diagrams to illustrate the communication connections.
3.10.1.
RS-232 Serial
Direct Personal Computer Link (RX, TX, GND)
Figure 3: RS-232 - Instrument to PC using COM Port (DB9)
Reference Manual Rev 1.31 Page 12
004R-623-140
Printer Connections (TX, DTR and GND)
Figure 4: RS-232 – Instrument to Printer (DB25)
Remote Display (TXD, GND)
Refer to documentation supplied with the Remote Display for connection details. Connect
RX on the Remote Display with TX on the instrument and connect the RS232 GND
signals together.
3.10.2.
RS-485 Serial
Remote Display (TA, TB)
RS485 is recommended for communicating over distances long
Reference Manual Rev 1.31 Page 14
004R-623-140
3.12. Connecting Shields
To obtain full EMC or for RFI immunity, cable shields MUST be connected and the
earth lug on the rear of the instrument must be grounded.
Figure 6 illustrates an example of possible connections. Also shown are the connecting cables
restrained using cable ties fastened by screws into the rear of the unit.
Figure 6: Cable Shield Connection
Reference Manual Rev 1.40 004R-623-140
Page 15
3.12.1.
Cable Shield Connection and Earthing
• Care should be taken when connecting shields to maximise EMC or RFI immunity and
minimise earth loops and cross-talk (interference) between instruments.
• For full EMC or for RFI immunity, termination of the cable shields to the connectors is very
important. The earth lug of the instrument must be separately connected to ground potential
via a reliable link.
�
Reference Manual Rev 1.31 Page 16
004R-623-140
A summary of the module resource usage is available in the instrument setup menus. See
described in section 1.1 page 42.
Note: Power supply options can only be connected in the left position. Other modules can
be connected in any position.
Reference Manual Rev 1.40 004R-623-140
Page 17
4.
Using Setup Menus
Throughout the setup menus different data entry methods are used. Each method is described
below.
4.1.
Accessing Setup Menus
There are two methods to access the Setup area:
• The Full Setup method provides access to all functions in Setup, including legal for trade
settings. Changes in Full Setup mode may result in the calibration counter being incremented.
If an attempt is made to enter
Reference Manual Rev 1.31 Page 18
004R-623-140
4.1.1. Setup Display Prompts
When accessing Full or Safe Setup the instrument will beep twice and enter the Setup
Menus. If a passcode has been configured, the P.CODE prompt will display and the correct
passcode must be entered to continue. Refer to Passcodes page 35 for more information.
If access is granted the following is displayed:
FULL (SAFE) → SETUP → Software Version (e.g. V1.0) → Serial Number
�