Rinstrum 400 Series Reference Manual

Text of Rinstrum 400 Series Reference Manual

All Rights Reserved. No part of this document may be

copied, reproduced, republished, uploaded, posted, transmitted, distributed, stored in or introduced into a retrieval system in any form, or by any means (electronic, mechanical, photocopying, recording or otherwise) whatsoever without prior written permission of Rinstrum Pty Ltd. Disclaimer Rinstrum Pty Ltd reserves the right to make changes to the products contained in this manual in order to

Reference Manual Rev 1.40

004R-623-140 Page 1 Table of Contents 1. INTRODUCTION ................................................................................................................... 5 1.1. Overview .................................................................................................................... 5 1.2. Document Conventions .............................................................................................. 6 2. SPE

Rinstrum 400 Series Reference Manual Rev 1.31

Page 2 004R-623-140 6. CONFIGURATION............................................................................................................... 35 6.1. General Setup Information ........................................................................................ 35 6.2. Calibration Counter................................................................................................... 35 6.3. Passcodes ..................
Reference Manual Rev 1.40 004R-623-140 Page 3 8.7.2. AUTO.n (Automatic Output Configuration) ................................................ 54 8.8. PRINT (Printouts) ..................................................................................................... 55 8.8.1. NUM (Number of printouts) ....................................................................... 55 8.8.2. HEADER (Print header) ..................................................
Reference Manual Rev 1.31 Page 4 004R-623-140 14.3. Analogue Weight Transmission ................................................................................ 86 15. APPENDIX 1: DIMENSIONS ............................................................................................... 87 15.1. Dimensions .............................................................................................................. 87 15.2. Legal Sealing Details ..........
Reference Manual Rev 1.40 004R-623-140 Page 5 1. Introduction 1.1. Overview This precision digital summing indicator can sum up to nine slave indicators from either the R300 or R400 range. These can be connected together on a multi-drop serial RS485 bus or RS232 ring network. The summing indicator polls each of the slave units summing all of the weight readings and displays the resulting total weight. The setpointing, printing facilities, and accessory mod
Reference Manual Rev 1.31 Page 6 004R-623-140 The instrument can support different software applications depending on the functionality required. This manual covers the K481 summing indicator. Please refer to the relevant manual for the slave indicators. 1.2. Document Conventions The following document conventions (typographical) are used throughout this Reference Manual. Bold Text Bold text denotes words and phrases to note. denotes a Keypad k
Reference Manual Rev 1.40 004R-623-140 Page 7 2. Specifications Performance Operating Environment Temperature: –10 to +50C ambient Humidity: <90% non-condensing Storage: –20 to +50C ambient IP55 when panel mounted or with rear boot (otherwise IP40) Case Materials ABS, Silicon Rubber, Nylon, Acrylic (no halogen used) Packing Weights Basic Indicator: 0.6kg Digital Display LCD with 4 alpha-numeric displays and LED backlighting: • Primary display:
Reference Manual Rev 1.31 Page 8 004R-623-140 Software V1 V2 Summing Slaves 9 9 Summing Subtotals 4 4 Input/Outputs 32 32 Setpoints 8 16 External Keys 8 8 Assignable Functions 8 8 Analogue Output 1 1 Communication 1xRS232 Duplex and 1xRS485 TX only ✓ ✓ Additional Communications Modules ✓ ✓ Products 10 250 Automatic Output 2 2 Automatic Output – Custom format ✓ ✓ Single Automatic Output ✓ ✓ Printouts 2 2 Custom Printouts ✓ ✓ Report Pri
Reference Manual Rev 1.40 004R-623-140 Page 9 3. Installation 3.1. Introduction The following steps are required to set up the indicator. • Inspect indicator to ensure good condition. • Use connection diagrams to wire up slave indicator serial connections, power and auxiliary cables as required. • Use the drill hole template provided for hole locations. • Connect power to indicator and press key to turn the instrument ON. • Refer to the S
Reference Manual Rev 1.31 Page 10 004R-623-140 3.6. Cable Connections All cable connections are made to the rear of the instrument using pluggable screw terminals. It is not necessary to tin the ends of the wires with solder or to add crimp ferrules to the wires, however, these techniques are compatible with the terminals. Figure 2: Cable Connections 3.7. DC Power (DC PWR +, DC PWR –) The DC supply need not be regulated, provided that it is free of exces
Reference Manual Rev 1.40 004R-623-140 Page 11  Summing R320 Indicators using RS232 Ring Network 3.9. Load Cell Connection As this is a summing indicator, the loadcell connection is not required and should not be connected. 3.10. Auxiliary Connections This section provides diagrams to illustrate the communication connections. 3.10.1. RS-232 Serial  Direct Personal Computer Link (RX, TX, GND) Figure 3: RS-232 - Instrument to PC using COM Port (DB9)
Reference Manual Rev 1.31 Page 12 004R-623-140  Printer Connections (TX, DTR and GND) Figure 4: RS-232 – Instrument to Printer (DB25)  Remote Display (TXD, GND) Refer to documentation supplied with the Remote Display for connection details. Connect RX on the Remote Display with TX on the instrument and connect the RS232 GND signals together. 3.10.2. RS-485 Serial  Remote Display (TA, TB) RS485 is recommended for communicating over distances long
Reference Manual Rev 1.31 Page 14 004R-623-140 3.12. Connecting Shields To obtain full EMC or for RFI immunity, cable shields MUST be connected and the earth lug on the rear of the instrument must be grounded. Figure 6 illustrates an example of possible connections. Also shown are the connecting cables restrained using cable ties fastened by screws into the rear of the unit. Figure 6: Cable Shield Connection
Reference Manual Rev 1.40 004R-623-140 Page 15 3.12.1. Cable Shield Connection and Earthing • Care should be taken when connecting shields to maximise EMC or RFI immunity and minimise earth loops and cross-talk (interference) between instruments. • For full EMC or for RFI immunity, termination of the cable shields to the connectors is very important. The earth lug of the instrument must be separately connected to ground potential via a reliable link. �
Reference Manual Rev 1.31 Page 16 004R-623-140 A summary of the module resource usage is available in the instrument setup menus. See described in section 1.1 page 42. Note: Power supply options can only be connected in the left position. Other modules can be connected in any position.
Reference Manual Rev 1.40 004R-623-140 Page 17 4. Using Setup Menus Throughout the setup menus different data entry methods are used. Each method is described below. 4.1. Accessing Setup Menus There are two methods to access the Setup area: • The Full Setup method provides access to all functions in Setup, including legal for trade settings. Changes in Full Setup mode may result in the calibration counter being incremented. If an attempt is made to enter
Reference Manual Rev 1.31 Page 18 004R-623-140 4.1.1. Setup Display Prompts When accessing Full or Safe Setup the instrument will beep twice and enter the Setup Menus. If a passcode has been configured, the P.CODE prompt will display and the correct passcode must be entered to continue. Refer to Passcodes page 35 for more information. If access is granted the following is displayed: FULL (SAFE) → SETUP → Software Version (e.g. V1.0) → Serial Number �