Never install the detector in a location that causes an alarm in one technol-
ogy. Installations should start with the LED OFF when no target motion is
present. Never leave it to operate with the tri-color LED in a constant or inter-
mittent green, yellow, or red condition.
•
Point the unit away from outside traffic (roads/alleys). R
Apply power only after all
connections have been made and
inspected. Do not coil excess
wiring inside the detector.
•
Terminals 1 (-) & 2 (+): Voltage limits are 9
to 15VDC. Use no smaller than #22 AWG wire
pair (500 feet/150m max) between the detector
and the power source.
•
Terminals 3 & 4: Alarm relay (reed) contacts rated at 3 watts, 0.
To The Installer
Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user are vital to the continuous satisfactory operation of any
alarm system.
The installer should assume the responsibility of developing and offering a repair maintenance program to the user, as well as acquainting the user with the pr