Bewator BC615 Installation And User Manual
Text of the manual
Copyright © 2004 Bewator AB, Solna, Sweden.
Material from this manual may only be copied with the consent in writing of
Bewator. Bewator reserves the right to alter both the content of the manual and the
design of the product.
Document no: 80601-12
Bewator AB is part of Bewator Holding AB, which develops and markets a complete
security product range that in
BC615 Installation and User Manual
3
Contents
WHAT IS THE BC615?......................................................................5
Features included .....................................................................6
How does the card reader work? ............................................7
Security levels...........................................
BC615 Installation and User Manual)
Cancel card (without card).....................................................35
Program/change/erase common code..................................35
Program holidays....................................................................36
Delete individual holidays......................................................36
D
BC615 Installation and User Manual
5
What is the BC615?
BC615 is a compact card reader for magnetic cards – and BC615-Prox
is a compact card reader for proximity cards. Both models have
capacity for 1000 cards.
In the following chapters the name BC615 will refer to both models
because the only difference is the way of reading cards.
See also chapter Proxim
BC615 Installation and User Manual
Features included
These are the main features included in BC615:
•
Six different security levels. Various methods of opening the door,
e.g. Card, Card + PIN and Common code.
•
Built-in time clock. Enables time control of cards and security
levels. Holidays, half-days and holiday periods can be pre-
programmed.
•
Doo
BC615 Installation and User Manual
7
How does the card reader work?
BC615 can easily be adapted to the security requirements in a
particular building, a particular day of the week or time of day. To
make this possible you have to be familiar with the following concepts:
•
Security levels
•
Time zones
•
Day types
•
Time schedules
Security levels
The s
BC615 Installation and User Manual
Examples of timing security levels
During office hours, when there are people in the premises, the security
level may not need to be so high: Unlocked door or Common code may
be suitable levels.
During lunch time, the level may be raised to Card.
The remaining time, i.e. evenings, nights and weekends
Card + PIN is a suita
BC615 Installation and User Manual
9
Time zones and day types
There are two purposes of creating time zones:
•
To be able to assign different security levels to different times of
the day.
•
To be able to make certain cards valid at certain times.
Example: The working hours in an office could be as follows:
Monday to Friday:
08.30-11.59 and 13.00-17.59
L
BC615 Installation and User Manual
Each time zone may consist of two intervals. To be able to assign
suitable security levels to the office example above, the following time
zones are needed:
Time zone no
Applies
01
Applies 24 hours a day (all day types). Note:
Default time zone that can be changed.
02
08.30 – 11.59 and 13.00 – 17.59 Monday to
Friday