1 IR320-en-GB_V1.0 6/18

User Manual Extech Model IR320 Waterproof, Dual Laser IR Thermometer with Alarm 1. Introduction Thank you for selecting the Extech IR320 IR Thermometer. The IR320 is a professional non-contact infrared thermometer that measures surface temperature from infrared energy radiated by the target’s surface. We ship this meter fully tested and calibrated and, with proper use, it will provide years of reliable ser

2 IR320-en-GB_V1.0 6/18

4. Product Description Meter Description 1. Low Alarm Alert (blue indicator) 2. High Alarm Alert (red indicator) 3. Backlit LCD 4. RCL (Recall MIN-MAX-AVG-DIF) and down arrow button 5. M (Mode) button 6. Battery compartment 7. Battery compartment screw 8. HI-LO (alarm) and up arrow button 9. Laser pointer lenses 10. IR measurement lens 11. Measurement trigger 12. Tripod mount Display Description Automatic me

3 IR320-en-GB_V1.0 6/18

5. Operation Power On and Off Pull the trigger to power the meter, the LCD (and backlight) will turn on. The thermometer will power off automatically after approximately eight (8) seconds. Manual Measurements 1. Pull and hold the trigger after aiming toward the target to measure. 2. The SCAN icon will flash while measuring the targeted surface or object. The center of the measurement spot is equidistant betw

Extech Instruments IR320 4 IR320-en-GB_V1.0 6/18

Emissivity Setting With the meter ON, short press the M button three (3) times to step to the emissivity screen. Use the up/down buttons to set the desired value (from 0.10 ~ 1.00). Short press the up or down button to add or subtract 0.01 units or long press to change the units rapidly. The meter will exit the setup mode after five (5) seconds of button inactivity. For more, see the Emissivity Consideration

5 IR320-en-GB_V1.0 6/18

7. Emissivity Considerations The Emissivity setting is shown in small digits at the lower left corner of the display. To adjust the Emissivity please refer to the Emissivity Setting section. Emissivity represents the reflectivity of a material. Most organic materials and painted or oxidized surfaces have an emissivity of approximately 0.95. Masking tape or flat black paint should be applied to cover the meas

Extech Instruments IR320 6 IR320-en-GB_V1.0 6/18

8. Maintenance Cleaning To clean the lenses, use compressed air to clear dust and other particles, then carefully clean with a wet cotton swab, moistened with clean water. To clean the meter housing, wipe with a soft, damp cloth. Do not use solvents or abrasives. Do not immerse the meter in liquid. Battery Installation and Replacement Install or replace the 9V battery according to the following figure. Never

Extech Instruments IR320 7 IR320-en-GB_V1.0 6/18

9. Specifications Measurement Range -20oC~650 oC (-4oF ~1202 oF) Accuracy ≥0 oC: ±1.8 oC or ±1.8% of reading, whichever is greater < 0 oC: ±(1.8 oC +0.1 oC / oC) ≥32 oF: ±3.6 oF or ±1.8% of reading, whichever is greater < 32 oF: ±(3.6 oF +0.1 oF / oF) Temperature Coefficient 0.1 oC / oC (0.1 oF / oF) or ±0.1% of reading per degree, whichever is greater D:S Ratio 12:1 distance-to-spot ratio Emissiv

Extech Instruments Thermometer Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
AN200

User Manual: Extech Instruments AN200 (169521, Upd.10-07-2026)

14 0.36 Mb 187 38 10-07-2026
SDL500

Extech Instruments Thermometer Operation & user’s manual (File: PDF, 25-06-2026)

12 0.26 Mb 426 90 25-06-2026
42525A

42525A (Thermometer ePDF Manual, #6ANL1M)

8 0.29 Mb 947 152 18-06-2026
EasyView Dual K EA10

EasyView Dual K EA10 Operation & user’s manual - 63P21W

8 282 63 19-08-2026
42515

42515 Operation & user’s manual - 562HPZ

9 0.18 Mb 516 114 12-06-2026
EA15

Thermometer #ZNLZ6H

6 645 123 12-06-2026

Thermometer: Similar Manuals