The following instructions are designed to assist in the
disassembly, reassembly and troubleshooting of
MegaStreamTM attenuators in Valtek® valves. Product
users and maintenance personnel should thoroughly
review this bulletin in conjunction with Installation,
Operation, Maintenance Instructions 1 (Mark One and
Two Control Valves)
4. Fully retract the plug (stem clamp indicator pointing
to the open position) and lower the actuator, bonnet
and plug squarely into the body and attenuator.
CAUTION: The bonnet aligns closely to the
body. Damage could result from misalignment
of the plug and attenuator; therefore, extreme
caution should be exercised in this operation to
make sure it
taken to lift the actuator and plug straight out of
the valve body. Any scraping of parts while
removing the actuator may damage valve parts.
When the actuator is not equipped with a lifting
ring, do not attach one; instead, lift the actuator
by using lifting straps through the yoke legs. In
this case, the center of gravity may be above the
lifting po
inches to allow the use of a ring compressor on the
metal rings. A suitable sized screw-type hose clamp
will also serve to compress the rings for reassembly.
Care should be taken to avoid damaging the sealing
surfaces while fitting the plug into the sleeve bore.
4. Once the bonnet is resting on the body, reinstall and
tighten the bonnet flange bolting