Flowserve Valtek MegaStream Installation, Operation & Maintenance Instructions

Text of Flowserve Valtek MegaStream Installation, Operation & Maintenance Instructions

The following instructions are designed to assist in the

disassembly, reassembly and troubleshooting of MegaStreamTM attenuators in Valtek® valves. Product users and maintenance personnel should thoroughly review this bulletin in conjunction with Installation, Operation, Maintenance Instructions 1 (Mark One and Two Control Valves)

4. Fully retract the plug (stem clamp indicator pointing

to the open position) and lower the actuator, bonnet and plug squarely into the body and attenuator. CAUTION: The bonnet aligns closely to the body. Damage could result from misalignment of the plug and attenuator; therefore, extreme caution should be exercised in this operation to make sure it

taken to lift the actuator and plug straight out of

the valve body. Any scraping of parts while removing the actuator may damage valve parts. When the actuator is not equipped with a lifting ring, do not attach one; instead, lift the actuator by using lifting straps through the yoke legs. In this case, the center of gravity may be above the lifting po

inches to allow the use of a ring compressor on the

metal rings. A suitable sized screw-type hose clamp will also serve to compress the rings for reassembly. Care should be taken to avoid damaging the sealing surfaces while fitting the plug into the sleeve bore. 4. Once the bonnet is resting on the body, reinstall and tighten the bonnet flange bolting

Flowserve Control Unit Owners Instructions: