Flowserve Valtek Assembly Instruction Manual

Text of Flowserve Valtek Assembly Instruction Manual

Valtek No. 49024

14-1 GENERAL INFORMATION The following instructions are designed to assist in installing, disassembling and troubleshooting Valtek® globe valves equipped with extended bonnets. Product users and maintenance personnel should thoroughly review this bulletin in conjunction with Installation, Op- eration Maintenance Instructions 1 (Mark One and

Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611

9. If the one-piece, cryogenic bonnet’s lower stem guide requires replacement, remove the lower guide by filing or grinding away the six peened- points around the guide. File away only the material necessary to free the guide. CAUTION: The cryogenic bonnet is designed for the lower

Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611

CAUTION: Do not distort the guide by using excessive force when peening. 2. If the packing has been removed and will be re- placed with packing other than square packing, reinstall the lower guide (in non-cryogenic, ex- tended bonnets only), 1/8-inch spacer, tube spacer, additional sp

Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611

Figure 3: Packing Configurations Extended Twin "V" With Purge Extended Twin "V" Extended "V" Vacuum Seal Twin "V" With Purge Extended Square Extended Twin Square With Purge Extended Twin Square IM014 Extended Bonnets.p65 8/21/01, 2:14 PM 4

Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611

Figure 4: Bolted Extension Figure 5: Bolted Flange Extension Bonnet (Item No. 40) Extension Bonnet (Item No. 41) Bolting (Item no. 110) Bonnet Extension Gasket (Item No. 60) Bolting (Item no. 110) Bonnet Extension Gasket (Item No. 60) Extension Bonnet (Item No. 41) Half Ring (Item No.

Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611

8. Remove the bonnet connecting bolts, extension clamps or flanges and half-rings (see Figures 4, 5, 6 and 7) and associated bolting. The bonnet flange may now be removed, if desired. 9. Pull apart the bonnet and bonnet extension and remove stem guides, packing, and packing spacers fr

Flowserve Control Unit Owners Instructions: