Istruzioni di installazione en CONTROLLER FOR BUILT-IN TWIN-CIRCUIT INSTALLATIONS Installation instructions fr APPAREIL POUR LA GESTION D’UN CIRCUIT MIXTE A ENCASTRER Instructions d’installation de STEUERUNGSSYSTEM FÜR INTEGRIERTE ZWEIKREISANLAGEN Einbauanleitung ...
Gentile Cliente, la nostra Azienda ritiene che il Suo nuovo prodotto soddisferà tutte le Sue esigenze. L’acquisto di un nostro prodotto garantisce quanto Lei si aspetta: un buon funzionamento ed un uso semplice e razionale. Quello che Le chiediamo è di non mettere da parte queste istruzioni senza averle prima lette: esse contengono informazioni utili per una corretta ed efficiente gestione della Suo prodotto. La nostra azienda dichiara che questi prodotti sono dotati di marcatura conformemente ai requisiti essenziali delle seguenti Direttive: - Direttiva Gas 2009/142/CE - ...
7222520.03 (1-11/15) DESCRIZIONE SIMBOLI AVVERTENZA Rischio di danno o di malfunzionamento dell'apparecchio. Prestare particolare attenzione alle avvertenze di pericolo che riguardano possibili danni alle persone. PERICOLO ALTA TENSIONE Parti elettriche in tensione, pericolo di shock elettrico. INFORMAZIONI IMPORTANTI Informazioni da leggere con particolare attenzione perchè utili al corretto funzionamento della caldaia. DIVIETO GENERICO Vietato effettuare/utilizzare quanto specificato a fianco del simbolo. AVVERTENZE DI SICUREZZA Le parti dell’imballo (sacchetti in plastica, polistirolo ecc.) non dev ...
2. INSTALLAZIONE L'apparecchio va installato all'interno della cassa/dima fornita a parte. Assicurarsi che il modello della cassa dima/dima sia corretto. 2.1 INSTALLAZIONE CASSA DIMA La cassa/dima deve essere inserita nel muro in una nicchia ricavata a tale scopo e bloccata con le apposite zanche laterali. Assicurarsi che l’installazione permetta una agevole manutenzione. La porta e la cornice in colore bianco devono essere rimosse e inserite solamente alla fine della fase di installazione (verificare che a corredo della cassa vi sia anche la chiave per l’apertura della porta). L ...
7222520.03 (1-11/15) 4. COLLEGAMENTO ELETTRICO L’apparechio deve essere collegato elettricamente ad una rete d’alimentazione 230V~ monofase con terra mediante il cavo a tre fili in dotazione. L’allacciamento deve essere effettuato tramite un interruttore bipolare (lo stesso che alimenta la caldaia), con apertura dei contatti di almeno 3 mm. In caso di sostituzione del cavo d’alimentazione, deve essere utilizzato un cavo armonizzato “HAR H05 VV-F” 3x0,75 mm2 con diametro massimo di 8 mm. Vedere schemi elettrici in SECTION B alla fine del manuale. Per togliere l'alimentazione elettrica premere ...
4.5 COLLEGAMENTO REGOLATORE AMBIENTE 1° ZONA BASSA TEMPERATURA Questa zona può essere comandata da un termostato ambiente o dal Controllo Remoto di caldaia. CASO TERMOSTATO AMBIENTE (accessorio a richiesta): Il contatto del termostato ambiente deve essere collegato ai morsetti H2-M del connettore della scheda elettronica dell MS THINK+ che regola la 1° zona in bassa temperatura (vedere schemi elettrici in SECTION B alla fine del manuale). CASO CONTROLLO REMOTO: Il contatto del Controllo Remoto deve essere collegato alla morsettiera M2 (1-2-3) della caldaia, per maggiori informazi ...
7222520.03 (1-11/15) 5.1 CONFIGURAZIONE SISTEMA Utilizzando il pannello di controllo entrare nel menù 2, come descritto nel capitolo 5, ed effettuare le seguenti impostazioni: RIGA DI PROGRAMMA VALORE DA IMPOSTARE DESCRIZIONE 5710 On Abilitazione del circuito di riscaldamento 1 (*) 5715 On Abilitazione del circuito di riscaldamento 2 5721 On Abilitazione del circuito di riscaldamento 3 5977 Termostato ambiente CR3 Abilitazione termostato per il circuito 3 (contatto 1-2 morsettiera M1 di caldaia) 6020 Circuito riscaldamento 1 Abilitazione della 1° zona di bassa temperatura (*) 6021 Circuito riscaldament ...
CONTROLLO REMOTO Nel caso in cui si collega un Controllo Remoto si deve configurare il parametro mediadiante l'utilizzo del Controllo Remoto, entrare nel menù 2, come descritto al capitolo 5, ed effettuare le seguenti impostazioni: RIGA DI PROGRAMMA VALORE DA IMPOSTARE DESCRIZIONE 40 Unità ambiente 1 Sonda ambiente abilitata nel controllo remoto della 1° zona di bassa temperatura CONFIGURAZIONE 2° ZONA BASSA TEMPERATURA TERMOSTATO AMBIENTE Nel caso in cui si collega un termostato ambiente si deve configurare il parametro mediante l'utilizzo del Controllo Remoto, accedere al menù ...
7222520.03 (1-11/15) 6. REGOLAZIONE DELLE POMPE AUTOMODULANTI Le pompe automodulanti sono dotate di una manopola con la quale è possibile attivare e disattivare tutte le funzioni e di un indicatore a LED posizionato intorno alla manopola stessa. Nella tabella che segue è riportata la diagnostica ed il significato della segnalazione luminosa del LED. POMPE DI ZONA Posizionando la manopola su (DP-v), la pompa modula la velocità variando linearmente il DP al variare delle perdite di carico dell'impianto. Questa impostazione è consigliata per impianti di riscaldamento con radiatori. Posizionando la man ...
8. LISTA ANOMALIE Anomalia Descrizione anomalia 10 Sonda esterna Circuito di riscaldamento abilitato senza nessun comando (termostato, unità ambiente o unità esterna) o sonda esterna guasta 30 Sonda mandata 1 Sonda del circuito miscelato 1 non rilevata 32 Sonda mandata 2 Sonda del circuito miscelato 2 non rilevata 84 BSB, conflitto di indirizzo 2 o più unità ambienti configurate per lo stesso circuito di riscaldamento 98 Modulo aggiuntivo 1 Accessorio AVS 75 non rilevato o riconosciuto 99 Modulo aggiuntivo 2 Accessorio AVS 75 non rilevato o riconosciuto 178 Limitatore temperat ...
7222520.03 (1-11/15) Dear Customer, Our company is confident our new product will meet all your requirements. Buying one of our products guarantees all your expectations: good performance combined with simple and rational use. Please do not put this booklet away without reading it first: it contains useful information for the correct and efficient use of your product. Our company declares that these products are marked in compliance with the essential requirements of the following Directives: - Gas Directive 2009/142/EC - Efficiency Directive 92/42/EEC - Electromagnetic Compatibility Directive 2004/108/ ...
DESCRIPTION OF SYMBOLS WARNING Risk of damage to or malfunction of the appliance. Pay special attention to the warnings concerning danger to people. DANGER - HIGH VOLTAGE Live components - electrocution hazard. IMPORTANT INFORMATION Information to read with particular care as it is useful for the correct operation of the boiler. GENERIC PROHIBITION It is forbidden to do/use the things indicated alongside the symbol. SAFETY WARNINGS Do not leave any packaging (plastic bags, polystyrene, etc.) within the reach of children as they are a potential source of danger. The appliance is not inten ...
7222520.03 (1-11/15) 2. INSTALLATION The appliance must be installed inside the template box, supplied separately. Ensure that the model of the template box is correct. 2.1 INSTALLING THE TEMPLATE BOX The template box must be fitted into the wall in a niche created for the purpose and blocked with special rag bolts at the sides. Make sure the installation allows easy access for maintenance. The door and the white frame must be removed and fitted only at the end of the installation phase (check that the key for opening the door is supplied with the box). The frame can be depth- adjusted by using the 4 butterf ...
4. ELECTRICAL CONNECTION The appliance must be electrically connected to a 230V~ single-phase power mains with earth by means of the three-core cable provided. Use a two-pole switch (the same one powering the boiler) with a contact gap of at least 3 mm. When replacing the power supply cable, fit a harmonised “HAR H05 VV-F” 3x0.75 mm2 cable with a maximum diameter of 8 mm. See the wiring diagrams in SECTION B at the end of this manual. To disconnect the electricity supply, press the switch in the junction box (light switch off = off). 4.1 BOILER ELECTRICAL CONNECTIONS M1 TERMINAL BOAR ...
7222520.03 (1-11/15) 4.5 CONNECTING THE LOW TEMPERATURE ZONE 1 ROOM CONTROLLER This zone can be controlled by a room thermostat or by the boiler Remote Control unit. ROOM THERMOSTAT (accessory available on request): The room thermostat contact must be connected to terminals H2-M of connector on the MS THINK+ electronic board which controls low temperature zone 1 (see the wiring diagrams in SECTION B at the end of this manual). REMOTE CONTROL UNIT: The Remote Control contact must be connected to the boiler terminal block M2 (1-2-3). For further information consult the boiler manual. This Remote Control Unit c ...
5.1 SYSTEM CONFIGURATION Enter menu 2 from the control panel, as described in section 5, and make the following settings: PROGRAMME ROW VALUE TO SET DESCRIPTION 5710 On Heating circuit 1 enable (*) 5715 On Heating circuit 2 enable 5721 On Heating circuit 3 enable 5977 Room thermostat CH3 Enable thermostat for circuit 3 (contact 1-2 boiler terminal block M1) 6020 Temps / mode CH1 Low temperature zone 1 enable (*) 6021 Temps / mode CH2 Low temperature zone 2 enable 6024 Limit thermostat CH EX21 input enabled as low temperature zone 1 protection (*) 6026 Limit thermostat CH EX21 input enabl ...
7222520.03 (1-11/15) REMOTE CONTROL UNIT If a Remote Control unit is connected the parameter must be configured using the Remote Control unit. Access menu 2, as described in section 5, and make the following settings: PROGRAMME ROW VALUE TO SET DESCRIPTION 40 Room unit 1 Room sensor enabled in the remote control of low temperature zone 1 LOW TEMPERATURE ZONE 2 CONFIGURATION AMBIENT THERMOSTAT If a room thermostat is connected the parameter must be configured using the Remote Control unit. Access menu 2, as described in section 5, and make the following settings: PROGRAMME ROW VALUE TO SET DESCRIPTION 6054 Ro ...
6. ADJUSTING THE SELF-MODULATING PUMPS The self-modulating pumps have a knob for enabling and disabling all the functions, and a LED indicator around the same knob. The diagnostics and meaning of the light signals of the LED are indicated in the table below. ZONE PUMPS Turn the knob to (DP-v) and the pump regulates the speed by adjusting the DP according to the pressure loss of the system. This adjustment is recommended for heating systems with radiators. Turn the knob to (DP-c) and the pump regulates the speed while keeping the DP constant in relation to the pressure loss of the syste ...
7222520.03 (1-11/15) 8. LIST OF FAULTS Fault Description of fault 10 External probe sensor Heating circuit enabled with no command (thermostat, room unit or external unit) or external probe faulty 30 Flow sensor 1 Mixed circuit 1 sensor not detected 32 Flow sensor 2 Mixed circuit 2 sensor not detected 84 BSB, address conflict 2 or more room units configured for the same heating circuit 98 Additional module 1 AVS 75 accessory not detected or recognised 99 Additional module 2 AVS 75 accessory not detected or recognised 178 Temperature limiter temps/mode CH1 Limit thermostat in mixed circuit 1 tripped (temporar ...
Cher Client, notre Maison ose espérer que votre nouvel appareil saura répondre à toutes vos exigences. L'achat de l'un de nos produits vous apportera ce que vous recherchez : un fonctionnement irréprochable et une utilisation simple et rationnelle. Nous vous demandons de lire cette notice d'utilisation avant d’utiliser votre chaudière car elles fournissent des informations utiles pour une gestion correcte et efficace de votre produit. Notre société déclare que ces produits possèdent le marquage conformément aux conditions essentielles des Directives suivant ...