Fig 1. Voltage measurement
DC and AC
Fig 2. Current measurement DC
Fig 3. Resistance measurement
Diode test
Continuity test
Fig 4. Dwell test
Engine tach/Rotation speed
500 Auto
LIMIT 500 Auto 1000V DC or 750
200V
100mV
V AC continuous
1000V
1V
±(0,8%+5)
AC Voltage
Range
Resolution
Accuracy
Overload
Protection
2V
1mV
20V
10mV
±(0.8%+5)
1000V DC or 750
200V
100mV
V AC continuous
750V
1V
±(1.0%+4)
DC Current
Range
Resolution
Accuracy
Overload
Protection
200mA
0.1mA
±(0.8%+5)
CE: Fuse 315mA, 250V,
fast type, 5x20 mm
10mA
10mA
±(1.2%+5)
CE: F
Tach (Rotation Speed) test
Range
Resolution
Accuracy
Overload
Protection
4CYL
6CYL
10 RPM
± (3%+5)
600Vp
8CYL
3
Tabels
English . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-14
Svenska . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15-22
Norsk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23-30
Dansk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31-39
Suomi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40-48
Deutsch . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage DC and AC
Current
Resistance
Diodes test
Continuity test
Dwell test
Engine tach/Rotation speed
Diagnosis test of fuses, switch, solenoid, relay etc.
Battery condition test
Battery consumption test
Battery charging test
Replace battery
Replace fuses
Contents