Before you start Thank you for your interest in Radiodetection’s RD500 Plastic Pipe Locator Kit Please read this user manual in its entirety before attempting to use the RD500 system as it contains many important safety notices and warnings. Radiodetection products, including this manual, are under continuous development. The information contained within is accurate at the time of publication; however the RD500, this manual and all its conten

3 | P a g e

Section Title Page INTRODUCTION PART 1 - OPERATING GUIDE 5 1.0 Unpacking and Setup 5 2.0 Fast Start Guide 5 3.0 Pulse Transmitter Application Techniques 6 4.0 Locator Application Techniques 7 5.0 Locator & Adapter Kit Details 8 5.1 Locator Kit Details 8 5.2 Sprinkler/Hose Bib Kit Details 9 5.3 Fire Hydrant Kit Details 9 5.4 RD500-Tx Electronic Pulse Transmitter 10 5.5 Water Meter Kit Details 10 PART II - TROUBLESHOOTING GUIDE 1.0 Introduc

4 | P a g e

List of Figures & Tables Figure Title Page PART 1 - FIGURES 5.1 Locator Kit Details 8 5.2 Sprinkler/ Hose Bib Kit Details 9 5.3 Fire Hydrant Kit Details 9 5.4 RD500-TX kit details 10 5.5 Water Meter Standpipe Kit Details 10 PART II - FIGURES 2.1 Pulse Transmitter Photograph 11 2.2 Pulse Transmitter Simplified Block Diagram 12 3.1 Locator Photograph 17 3.2 RD500 Theory and use 21 LIST OF TABLES Table 2.1 Pulse Transmitter Type S

5 | P a g e

INTRODUCTION Thank you for purchasing the most cost-effective plastic pipe locator tool available. The purpose of this manual is to provide useful information that will help you get the best possible results from your new locator. This operating guide contains directions for unpacking, setting up and operating the RD500 system. It also contains a fast start guide that will enable users to quickly begin locating water pipes. This is followed by

6 | P a g e

4. Begin initial tracing about 2 metres from Pulse Transmitter or any other area where pipe location is known 5. Push spike of Locator into ground near known pipe location and turn ON/ OFF knob clockwise for mid-range meter reading and adjust individual headphone controls for comfortable listening level 6. To pinpoint pipe position, use Locator to probe ground until you find peak (maximum) meter reading. You will also hear the pulsing sound (si

7 | P a g e

Check the water pressure before attempting to locate the water line and make sure that it is in the operating range of the Pulse Transmitter, which is 3 to 10 Bars (40 to 140 psi). The Pulse Transmitters are color-coded to identify their intended usage: A color-coded ty-wrap is used along with a small square area that is painted on the side of the Pulse Transmitter to indicate the color. Green is the lowest power Pulse Transmitter and is intend

Radiodetection RD500 8 | P a g e

Best location results are obtained by beginning your tracing at least 3 metres from the location where the Pulse Transmitter is connected. The signal levels are normally too strong in the area immediately surrounding the Pulse Transmitter. Alternately, tracing may begin at a known pipe location that is not more than 75 metres down the pipe from the Pulse Transmitter. The preferred method for tracing pipes is to locate at least two known pipe lo

11 | P a g e

Lock Nut Serial Number Outlet Coloured Ty-wrap Inlet PART II - TROUBLESHOOTING GUIDE 1.0 Introduction: This part of the manual is divided into two major subjects. Section 2 covers the Pulse Transmitter and Section 3 covers the Locator. Each section is organized to first provide an overview of the equipment and its major components. This is followed by a set of tests that can be performed by the user to locate problems. 2.0 Mechanical Pulse Tra

12 | P a g e

Figure 2.2 Pulse Transmitter Simplified Block Diagram Figure 2.2 is a simplified block diagram of the Pulse Transmitter illustrating the operation of the valve. Valve opening and closing is controlled by the adjustable T-handle. Turning the handle clockwise increases the spring force and causes the valve to open (water starts flowing), while rotating it anticlockwise reduces the spring force allowing it to close (water stops flowing). A handle

13 | P a g e

Larger diameter pipes require higher flow rates to produce a strong signal output. The three types of Pulse Transmitters currently offered are summarized in Table 2.1 below: Table 2.1 - Pulse Transmitter Type Summary Power/ Color Code Diameter of Pipe Service Type Low / GREEN Medium / YELLOW High / RED* ≤ 5cm > 5cm > 15cm Service and Sprinkler lines Small Water Main Large Water Mains *CAUTION: RED PULSE TRANSMITTERS SHOULD ONLY BE USED ON

14 | P a g e

2.2.1.2 Leak Tests: 1. Connect the Pulse Transmitter to the appropriate water pipe using all of the adapter kit provided. DO NOT connect the water hose to the Pulse Transmitter outlet during this test. 2. Turn the water fully on and turn the T-handle on the Pulse Transmitter anticlockwise until water stops flowing completely. 3. Observe the area around the inlet of the Pulse Transmitter. If any leaks occur, check the inlet filter screen washer

15 | P a g e

2. Turn the water fully on (open valve completely). 3. Loosen the T-handle collar (knurled ring or hex-shaped collar just above T-handle). Turn the T-handle on the Pulse Transmitter clockwise until water starts flowing through the water hose on the outlet. 4. Slowly turn the T-handle anticlockwise until the Pulse Transmitter starts to pulse. 5. Turn the T-handle clockwise until the pulsing stops and observe its position (rotational location) a

16 | P a g e

Table 2.3 RD500-Tx. Electronic Pulse transmitter failure symptoms and causes SYMPTOM OBSERVED LIKELY CAUSE (S) No pulse from electronic Pulse transmitter when Power is switched on Battery flat , Check indicator on RD500-Tx power Control unit Check 12v DC supply is connected 3.0 RD500 Locator Repairs 3.1 Purpose of the RD500 Locator: The RD500 Locator picks up the signal created inside the pipe by the Pulse Transmitter. The Pulse Transmi

Radiodetection RD500 17 | P a g e

seal the upper control housing and a decorative black bezel is installed over the face of the meter. The meter assembly is connected to the control housing by a single 8-pin connector. 3.2.1 RD500 Locator Tests: The following tests can be easily performed by a user to help determine if a problem(s) exists in the RD500 Locator. Please see Figure 3.2 to clarify the location of specific parts. 3.2.1.1 Battery Tests: The RD500 Locator battery may

Radiodetection RD500 18 | P a g e

3.2.1.2 Locator Sensitivity Tests: Each RD500 Locator Assembly is calibrated at the factory to produce specific meter signal levels when the complete assembly is tested with a platform that produces controlled levels of motion. The following test can be conducted without special equipment to determine if your Locator has sensitivity problems and should be returned to Radiodetection for repair. NOTE: the ON/ OFF SENSITIVITY Switch (located dire

19 | P a g e

9. If the meter does not return below 10% quickly after being tapped, and you hear a tone, then the Locator is breaking into oscillation and may need to be returned to Radiodetection for repair. 10. If a tone (oscillation) is heard, try reducing the sensitivity by turning the knob anticlockwise about 1/ 4 turn. If this does not help, watch the meter and observe its response when oscillating, then try disconnecting the headphones and repeating

Radiodetection Measuring Instruments Owners Instructions: