S1-E / S1-A

® English / Suomi / Svenska / Magyar Instructions for use Käyttöohje Bruksanvisning Kezelői kézikönyv ...

Instructions for use

2 6567452  D3643.201.01.03.02 Content 1 Before you begin … ...................................................................................... 5 1.1 Structure of the document ........................................................................................... 6 2 Safety instructions......................................................................................... 9 3 Technical description .................................................................................... 11 3.1 Task ......................................................................................................................... ...

Instructions for use

Content 6567452  D3643.201.01.03.02 3 English 5 Operation ...................................................................................................... 21 5.1 Replacing the instrument ............................................................................................. 22 5.2 Attaching and removing a file ...................................................................................... 23 5.3 Attaching the Apex clip ................................................................................................ 25 5.4 Connecting the instrument to an endometer.................................................. ...

Instructions for use

4 6567452  D3643.201.01.03.02 7.3 Manual cleaning and disinfection................................................................................. 38 7.4 Manual maintenance ................................................................................................... 40 7.5 Sterilizing ..................................................................................................................... 44 8 Spare parts and consumables ...................................................................... 46 9 Disposal .................................................................................................... ...

Instructions for use

1 Before you begin … 6567452  D3643.201.01.03.02 5 English 1 Before you begin … S1-E / S1-A complies with the regulations taking into account the state of the art. S1-E / S1-A complies with the ISO 14457 standard. 1. Read the operating instructions prior to using S1-E / S1-A. 2. Use S1-E / S1-A only for the applications described in the operating instructions. 3. Observe the hygiene standards, occupational safety regulations, and accident prevention measures applicable to the S1-E / S1-A in your country. Intended use S1-E / S1-A is used to hold and drive burs for the purposes of rotary processing and is intended for the follo ...

1 Before you begin …

Instructions for use 6 6567452  D3643.201.01.03.02 Target group This product is intended only for use by trained dental personnel in dental practices and laboratories. 1.1 Structure of the document 1.1.1 Labeling of information Warnings ➢ To prevent injuries, please observe the warnings. Warnings are labeled as follows: DANGER!  indicates a danger leading to death or serious injury if not avoided. WARNING!  indicates a danger that may lead to death or serious injury if not avoided. CAUTION!  indicates a danger that may lead to injury if not avoided. Instructions for use ➢ To prevent material damage and additional expe ...

Instructions for use

1 Before you begin … 6567452  D3643.201.01.03.02 7 English Instructions for use are labeled as follows: NOTE!  indicates measures for the prevention of material damage. IMPORTANT: indicates information on the avoidance of additional expenses and other important information. Tip: indicates information for facilitating work. ...

1 Before you begin …

Instructions for use 8 6567452  D3643.201.01.03.02 1.1.2 Formats and symbols The formats and symbols used in this document have the following meaning: ü Prerequisite 1. First action step 2. Second action step or ➢ Alternative action Ä Result ➢ Individual action step Requests you to do something. Use of formats and symbols  [→ 8]. Identifies a reference to another text passage and specifies its page number. ● List Identifies a list. ...

Instructions for use

2 Safety instructions 6567452  D3643.201.01.03.02 9 English 2 Safety instructions Obligations of the user ● Use only fault-free materials that do not deviate from the specified data  [→ 15]. ● Protect yourself, patients, and others from danger. To do this, observe the safety information. ● Comply with the Intended use of the equipment. ● You should always keep these operating instructions within reach for further reference. Preventing the spread of infections and cross contamination Prevent the spread of infections and cross contamination between patients, users, and third parties. Sterilize equipment after each pati ...

2 Safety instructions

Instructions for use 10 6567452  D3643.201.01.03.02 Instrument head/body overheating If the instrument is defective, the area around the instrument head or the instrument body may heat up, thus creating a risk of burning the hands or the patient's oral mucosa. Malfunction or damage Discontinue use immediately in case of malfunction, unusual or different sounds or damage. Damaged instruments may cause injury. Notify the dental depot or the manufacturer. Repair Do not repair the instrument yourself. Spare and accessory parts Use only original parts produced by the manufacturer. Operating conditions: Temperature: +10 °C – +30 ° ...

Instructions for use

3 Technical description 6567452  D3643.201.01.03.02 11 English 3 Technical description 3.1 Task The instrument serves for transmitting the driving power of the electric motor or air motor (handpiece coupling according to ISO 3964) to the preparation tool and converts a rotational movement into a rotating movement with alternating direction. ...

3 Technical description

Instructions for use 12 6567452  D3643.201.01.03.02 3.2 Set up A Instrument head B Push button C Opening of chuck system D Joint for clip ...

Instructions for use

3 Technical description 6567452  D3643.201.01.03.02 13 English Accessories A Insulating sleeve B Clip 3.3 Overview of files Following files are to use for the application with S1-E / S1-A: Designation ISO/Taper Sendoline - S1 Plus Standard 25/06 Sendoline - S1 Plus Small 15/06 ...

3 Technical description

Instructions for use 14 6567452  D3643.201.01.03.02 Designation ISO/Taper Sendoline - S1 Plus Large 40/04 Sendoline – S1 File Standard 25/06 25/06 Sendoline – S1 File 15/06 15/06 Sendoline - S5 Rotary File #1 30/08 Sendoline - S5 Rotary File #2 30/06 Sendoline - S5 Rotary File #3 30/04 Sendoline - S5 Rotary File #4 25/04 Sendoline - S5 Rotary File #5 20/04 Sendoline - Big Apical File 35/04 Sendoline - Big Apical File 40/04 ...

Instructions for use

3 Technical description 6567452  D3643.201.01.03.02 15 English Designation ISO/Taper Sendoline - Big Apical File 45/04 Sendoline - Big Apical File 50/04 3.4 Technical Data S1-E S1-A Gear ratio ~ 150:1 ~ 82:1 Maximum motor speed in rpm ~ 40 000 ~ 22 000 Mean speed at maximum motor speed in rpm ~ 270 ~ 270 Motion forward and backward rotat- ing forward and backward rotat- ing Clockwise rotation angle ~ 180° ~ 180° ...

3 Technical description

Instructions for use 16 6567452  D3643.201.01.03.02 S1-E S1-A Counterclockwise rotation angle ~ 30° ~ 30° Periodicity of the motion in Hz ~ 10.7 ~ 10.7 Clamping system CA CA Internal cooling media - - Light function - - Apex measurement function x x Clips available for standard endometer connections ⌀ 2 mm ⌀ 2 mm Instrument coupling ISO 3964 ISO 3964 ...

Instructions for use

3 Technical description 6567452  D3643.201.01.03.02 17 English File S1-E / S1-A Shank diameter in mm 2.334 - 2.350 Maximum total length in mm 42 Maximum working diameter in mm (ISO 2157) 2.1 Gripping length in mm ≥ 11 Standard ISO 1797-1 ...

3 Technical description

Instructions for use 18 6567452  D3643.201.01.03.02 3.5 Product labeling Can be thermally disinfected 134°C Sterilizable in a steam sterilizer (autoclave) at the temperature specified Data matrix code (here: an example) Content of the data matrix code: B C D +ESEN6542471/$$+5192/16D20170309E A ...

Medical Equipment PDF Instructions

Ibex EVO
E. I. Medical Imaging Ibex EVO
11.08.2026 118 pages

Ibex® EVO® Portable Ultrasound User Guide Published 9/17/2018 E.I. Medical Imaging User Manual 391250, Rev. 4 Device operation guide for the E. I. Medical Imaging Ibex EVO Medical Equipment. The manual outlines system configuration and compatibility information, device calibration, operating guidelines.

Splashy
Firefly Splashy
17.08.2026 36 pages

User Manual Family Freedom English Splas lashy Professional user manual for the Firefly Splashy Car Seat. This guide offers instructions on operational procedures, setup instructions, wiring diagrams, technical specifications.

SUPER TOBI SUCTION ASPIRATOR
Gima SUPER TOBI SUCTION ASPIRATOR
12.05.2026 68 pages

ASPIRATORE CHIRURGICO SUPER TOBI SUPER TOBI SUCTION ASPIRATOR ASPIRATEUR SUPER TOBI CHIRURGISCHER ABSAUGER SUPER TOBI ASPIRADOR QUIRÚRGICO SUPER TOBI APARELHO DE SUCḈÃO CIRÚRGICO SUPER TOBI M28224-M-Rev.1-01.21 PROFESSIONAL MEDICAL PRODUCTS Gima S.p.A. Official user manual for the Gima SUPER TOBI SUCTION ASPIRATOR Medical Equipment. It explains configuration options and daily usage, setup instructions, user preferences, usage recommendations.

REAL 8100
Mercado Medic REAL 8100
25.08.2026 2 pages

Seat tilt adjustment is available in two models: crank or electrically regulated. For the crank regulated seat, the angle is adjusted using the knob (1). The tilt increments (+15˚/-8˚) can be fixed using the nuts (2). Electric tilt adjustment can be regulat Full technical guide for the Mercado Medic REAL 8100 Medical Equipment. This reference manual explains assembly reference, troubleshooting tips, hardware components, performance guidelines.