Purkeys SELECT Diagnostics Manual

Text of Purkeys SELECT Diagnostics Manual

P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net

CONTENTS General Information.........................................................................2 Select Call-Outs...............................................................................3 Wire Diagram and Legend..............................................................4 Diagnostics......................................................................................6 Excessive Voltage Dr

The Purkeys’ Select™ system allows charging from multiple

sources and improves the charging of liftgate batteries by utilizing a DC/DC converter to boost the voltage for optimal charging. The boost in voltage overcomes the normal voltage drop caused by the extended distance between the liftgate batteries and the vehicle charging system. Also, in cold temperatures batteries require increased charging voltages to maintain a high state of charge. The DC

WIRE DIAGRAM AND LEGEND

A. Liftgate Battery Box B. Liftgate Battery Pack C. P1020-K Liftgate Charging System Plate Assembly D. 30 Amp Circuit Breaker E. DC/DC Converter F. DC/DC Converter Output Stud G. DC/DC Converter Input Stud (+) H. DC/DC Converter Input Stud (-) I. 2 Amp Inline Fuse from Liftgate Batteries J. Select Controller K. Input Source (Stinger, 7-Way, Straight Truck Battery Pack, or Reefer Unit) all-guide s.com
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net SELECT DIAGNOSTIC GUIDE WIRE COLOR WIRE GAUGE CONNECT FROM CONNECT TO Blue 10 Power In Input Source (+) (stinger, 7-way, straight truck battery pack, or reefer unit) White 10 Ground Input Source (-) White 8 Ground Liftgate Battery (-) Fused DC/DC Converter Input Stud (-) Yellow 16 DC/DC Converter Ignition DC/DC Converter Ignition Stud Black 8 Select Controller Power Out to DC/DC converter DC/DC Converte

If there is excessive voltage drop between the source battery

and the Select Controller, both Source and Lift Battery LEDs will briefly turn green, indicating that the Select is trying to charge the batteries. Then both LEDs will toggle orange for a few seconds. This cycle then repeats (this could happen on any input source; see Figure 1 for examples showing this issue on the 7-way aux input). The circuit needs to be tested while under load to determine
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net SELECT DIAGNOSTIC GUIDE STATIC DIAGNOSTICS Not connected to a charging source or not charging (at rest) (see Figure 2 for location of Liftgate Battery LED; see Figure 3 for LED status reference, located on right side of Select Controller). Figure 2 Figure 3 LED STATUS CONDITION ACTION NEEDED REFERENCE Slow Flashing Green Liftgate batteries in good state of charge (more than 12.4 volts). None. Slow Flash

No LED: Open circuit between liftgate battery positive or liftgate

battery ground and the Select Controller. Follow the steps below to diagnose the No LED Status (see Figure 5). Figure 5 Step 1: Using a voltmeter, measure the voltage between the DC/DC converter side of the circuit breaker and the negative post on the liftgate battery (see V1 in Figure 5). If the reading is less than 12.0 V, charge or replace the batteries. If the battery rea

Purkeys Battery Charger Owners Instructions: