Purkeys SELECT Diagnostics Manual
Text of Purkeys SELECT Diagnostics Manual
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net
CONTENTS
General Information.........................................................................2
Select Call-Outs...............................................................................3
Wire Diagram and Legend..............................................................4
Diagnostics......................................................................................6
Excessive Voltage Dr
The Purkeys’ Select™ system allows charging from multiple
sources and improves the charging of liftgate batteries by utilizing
a DC/DC converter to boost the voltage for optimal charging.
The boost in voltage overcomes the normal voltage drop caused
by the extended distance between the liftgate batteries and the
vehicle charging system. Also, in cold temperatures batteries
require increased charging voltages to maintain a high state of
charge. The DC
WIRE DIAGRAM AND LEGEND
A.
Liftgate Battery Box
B.
Liftgate Battery Pack
C.
P1020-K Liftgate Charging
System Plate Assembly
D.
30 Amp Circuit Breaker
E.
DC/DC Converter
F.
DC/DC Converter Output Stud
G.
DC/DC Converter Input Stud (+)
H.
DC/DC Converter Input Stud (-)
I.
2 Amp Inline Fuse from Liftgate Batteries
J.
Select Controller
K.
Input Source (Stinger, 7-Way, Straight
Truck Battery Pack, or Reefer Unit)
all-guide
s.com
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net SELECT DIAGNOSTIC GUIDE
WIRE
COLOR
WIRE
GAUGE
CONNECT FROM
CONNECT TO
Blue
10
Power In
Input Source (+)
(stinger, 7-way, straight
truck battery pack, or
reefer unit)
White
10
Ground
Input Source (-)
White
8
Ground Liftgate
Battery (-) Fused
DC/DC Converter Input
Stud (-)
Yellow
16
DC/DC Converter
Ignition
DC/DC Converter Ignition
Stud
Black
8
Select Controller
Power Out to
DC/DC converter
DC/DC Converte
If there is excessive voltage drop between the source battery
and the Select Controller, both Source and Lift Battery LEDs will
briefly turn green, indicating that the Select is trying to charge the
batteries. Then both LEDs will toggle orange for a few seconds.
This cycle then repeats (this could happen on any input source;
see Figure 1 for examples showing this issue on the 7-way aux
input).
The circuit needs to be tested while under load to determine
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net SELECT DIAGNOSTIC GUIDE
STATIC DIAGNOSTICS
Not connected to a charging source or not charging (at rest) (see
Figure 2 for location of Liftgate Battery LED; see Figure 3 for
LED status reference, located on right side of Select Controller).
Figure 2
Figure 3
LED STATUS
CONDITION
ACTION NEEDED REFERENCE
Slow
Flashing
Green
Liftgate batteries
in good state of
charge (more than
12.4 volts).
None.
Slow
Flash
No LED: Open circuit between liftgate battery positive or liftgate
battery ground and the Select Controller. Follow the steps below
to diagnose the No LED Status (see Figure 5).
Figure 5
Step 1: Using a voltmeter, measure the voltage between the
DC/DC converter side of the circuit breaker and the negative
post on the liftgate battery (see V1 in Figure 5). If the reading is
less than 12.0 V, charge or replace the batteries. If the battery
rea