Mircom RB-MD-1113 Installation Instructions
Text of Mircom RB-MD-1113 Installation Instructions
Replacement MD-1113 Module Board
Installation Instructions
The RB-MD-1113 kit comes with all the parts needed to replace an MD-1113 module board for a TX3-CX-A8 Aperio
Door Controller.
RB-MD-1113 Installation Instructions
To replace the MD-1113 you must:
A. Power down the TX3-CX-A8
B. Replace the MD-1113 module b
Figure 1: RB-MD-1113 Board Replacement
SW2
Power terminals for
16 Vac transformer
(PS-4 or PS-4P)
Input terminals
Output terminals
Connectors
for 12V
battery backup
P6
P5
BAT- BAT+
-
S +
-
S +
INPUT
OUTPUT
1
8
NC C NO
NC C NO
NC C NO
NC C NO
NC C NO
NC C NO
P7
Mounting
screws for the
MD-1113
OFF
ON
SW1
P3
Ribbon cable
connector for
MD-1113