Graco SD Series Instructions Manual
Text of Graco SD Series Instructions Manual
SD and XD 10/20
Series Hose Reels
For dispensing air, water, antifreeze, windshield washer solvent, transmission fluid, oil,
and grease. For professional use only.
Not approved for use in European explosive atmosphere locations.
Model:
See page 3 for model information, including maximum
working pressure and approvals.
Related Manuals
Important Safety Instructions
Read all warnings and instructions in this
manual before using the equ
Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SD Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
XD Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Typical Installation . . . . . . . . . . . . . . . .
(Part List page 31)
*Each HP Model hose reel shown in the table is available in several colors. The last character of each Model No.
indicates the hose reel color. For example: A = white + NPT, B = metallic blue + NPT, C = red + NPT, D = black + NPT,
F = yellow + NPT (other color choices may be available from your Graco Distributor).
The SD Series Models table uses the generic # symbol to represent the last character. Fo
(Part List page 35)
*Each HS or HN Model hose reel shown in the table is available in several colors. The last character of each Model
No. indicates the hose reel color. For example: A = white + NPT, B = metallic blue + NPT, F = yellow + NPT (other
color choices may be available from your Graco Distributor).
The XD Series Models table uses the generic # symbol to represent the last character. For example, to order a white
HSL2D
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The
exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks.
When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings.
Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
•
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
•
Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Specifications in all equipment manuals.
•
Use fluids and solvents that are compatible with equipment wetted parts. See Technical
Specifications in all equipment manu
Overhead-Mounted Hose Reel
Key:
A
Main Air Supply Line
B
Pump Air Supply Line
C
Air Filter
D
Air Regulator
E
Bleed-type Master Air Valve (required)
F
Pump
G
Pump Grounding Wire (required)
H
Fluid Drain Valve (required)
J
Fluid Shutoff Valve
K
Fluid Line
L
Hose Inlet Kit
M
Hose Reel
N
Dispense Valve
P
Mounting Channel/Base
FIG. 1: Typical Installation
A
B
C
D
E
F
G
H
J
K
J
L
P
M
N
The typical installation shown in FIG. 1 is only a guide for
selecting and installing a hose reel system. The
components shown are the minimum requirements for
all systems. However, it is not an actual system design.
Contact your Graco Distributor for assistance in
designing a system to suit your needs.
NOTE: The air and fluid accessories required for your
pump must be properly sized to the pump. Refer to your
pump manua