DVI DA Plus Series • User Guide
Introduction
This user guide describes the installation, operation, and specifications of the Extron® DVI DA4 Plus, DVI DA6 Plus, and
DVI DA8 Plus Distribution Amplifiers.
Unless stated otherwise, all references to the “distribution amplifier,” “DA,” or “DVI DA Plus Series” in this guide refer to the
features or operation of all three models.
FCC Class A Notice
This equipment has been tested and found to c
EDID Minder — The EDID Minder maintains continuous EDID communication with the attached source to ensure that the DVI
source powers up correctly and maintains a proper video output, even if the display is off.
EDID Lock — The last recorded EDID is saved to the input and used after a power cycle or after displays have been changed.
The EDID presented to the input is not affected by power cycles or changing the output displays (even with hot-plu
1 Power input — Connect the two pole, 3.5 mm captive screw connector from the power supply (provided with the unit) to this
socket on the rear panel.
12V
1.0A MAX
POWER
Back Panel
Power Receptacle
DC Power Cord
Captive Screw Connector
AC Power Cord
Ground
+12 VDC
External
Power Supply
(12 VDC, 1.0 A )
Figure 3.
Power Supply Connection
The external power supply in the illustration above (12 VDC, 1.0 A) is for use with the DVI DA4 Plus. The DVI DA6 Plus a
3 Output Connectors — Use DVI-I cables to connect up to four (DVI DA4 Plus), six (DVI DA6 Plus), or eight (DVI DA8 Plus)
display devices.
NOTE:
The actual signal transmission distance can vary and depends on signal resolution, cable quality, graphics card,
and display used in the system.
DVI Connector Pin Assignments
The illustration below shows the pin assignments for the DVI-I connectors.
Pin
Signal
1
TMDS data 2–
TMDS data 2+
TMDS data 1–
TMDS dat
When a DVI video source boots up, it normally communicates with the output device using the bidirectional Extended Display
Identification Data (EDID) communication protocol. The source device then produces a signal with a resolution that is compatible
with the output device.
The Extron EDID Minder feature maintains continuous EDID communication with the attached source and ensures that the DVI
source powers up correctly and maintains a proper v
By default the switches are in the “Off” (down) position, allowing the EDID information to be read from the
3
4
1
2
ON CIT
corresponding output. To deactivate EDID Minder for one or more outputs, move the switch for that output
to the “On” (up) position. In the diagram at right, the unit reads EDID from output 3, but not from outputs 1,
2, or 4.
5.
Replace the cover, using the screws that were removed in step 1.
EDID Lock
Some applications req
Pre-emphasis compensates for long cable runs, distortion, and pixilation on the distribution amplifier outputs. To enable
pre-emphasis:
1.
Remove and keep the screws holding the cover to the base. For the DVI DA4 Plus, there are three screws along the rear edge
of the top and two screws on each side. For the DVI DA6 Plus and DVI DA8 Plus, there are four screws along the rear edge of
the top and three screws along each side. Set aside the co
© 2008-2020 Extron Electronics — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
Mounting
This section outlines the various mounting options available for the DVI DA Plus series of distribution amplifiers.
Tabletop Placement
Attach the four provided rubber feet to the bottom of the unit and place it in an