Longrun 250LD2 Operation Manual
Text of Longrun 250LD2 Operation Manual
INVERTER DC STICK WELDER
250LD2, 300LD2
OPERATION MANUAL
DO NOT INSTALL, OPERATE OR MAINTAIN THIS MACHINE WITHOUT READING THIS MANUAL AND
PLEASE ALWAYS THINK BEFORE YOU ACT.
www.worldwel.com
MODEL
UNIT
250LD2
300LD2
INPUT VOLTAGE
V
220, Single phase
FREQUENCY
Hz
50/60
INPUT CAPACITY
KVA
9
11
NO LOAD VOLTAGE
V
80
82
CURRENT RANGE
A
20~250
20~300
VOLTAGE RANGE
General Safe Practices
Wear approved safety glasses with side shields under your welding helmet or face shield and at all times in
■
the work area.
When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.
■
Do not install or place machine on or over combustible surfaces.
■
Be sure that all installation,
Welding sparks can cause fire or explosion.
Remove fire hazards from the welding area. If this is not possible, cover them to prevent the welding
■
sparks from starting a fire. Remember that welding sparks and hot materials from welding can easily go
through small cracks and opening to adjacent areas. Avoid welding near hydraulic lines.
When not welding, m
FRONT CONTROL PANEL
●
POWER LAMP
①
WARNING LAMP
②
VOLTAGE REDUCING DEVICE LAMP
③
④ VOLTAGE REDUCING DEVICE SWITCH
AMMETER (DIGITAL DISPLAY)
⑤
⑥ OUTPUT CURRENT CONTROL