Ninglu SIM999 Operation Manual

Text of the manual

Speed Log Simulator

and NMEA0183 Tester SIM999 Operation Manual Document: NLT-SIM999-SSEN Edition: V140825

Introduction ........................................................................... 1

Features ............................................................................. 1 Functions ........................................................................... 1 Packing List ......................................................................

SIM999 is a handheld portable tester for Doppler speed log,transducer

and NMEA0183 (IEC61162-1). Doppler speed log tester SIM999 can measure the output of a Doppler speed log, and if required, reply with a user defined signal to simulate operation of the transducer. NMEA0183 tester SIM999 receives and displays the NMEA0183 signal. Features �

Receive and display the NMEA0183 signals output from the connected

device. Doppler speed log teaching system (optional) Optional part for speed log teaching system, please contact NINLGU if you need to this function.

connect speed log

with this unit NMEA cable 0.5m length 1 connect NMEA signal with this unit Battery charger (110/220V) 12.6V/350mA 1 charge build-in battery NMEA interface Charging port PC RS232 interface LED indicators Power on

Pulse yellow light will flash when receiving the input from speed log.

Echo red light will flash when outputting bottom echo signal. Note: The echo light will not flashing until the pulse light flashing. Power on/off: Switch on/ off power. Menu Navigation Buttons: Flashing cursor key, change the location of flashing cursor In

Display screen: 128×64 dot-matrix LCD

Dimension: 235mm×135mm×55mm Weight(battery included): 700g Build-in rechargeable lithium battery: 12.6VDC 1500mAh Battery charger: 12.6V/350mA Working temperature: -15~55℃ Analog Parameters Parameters Range Resoluti

Note: This manual introduces the operation of SIM999 by taking an

example of Ninglu DS99 Doppler speed log, but the SIM999 is not limited to connect with the DS99 and it can also be applied to other logs within the parameter ranges on Page 4 (Analog parameters). Charge Please charge when the battery is too low for extend the battery's life.

After the power-on, display the product's software version number and

welcome words first, and then enter the main menu with 1-3 options. Press or to change the location of the flashing cursor, press to enter the option, press or to change the parameters which will be saved automatically, and press to return to the previous menu. Main

After the power-on, display the product's software version number and

welcome words first, and then enter the main menu. For the change language, Press before you enter the main menu, then the language selection screen will appear, press or to change the location of the flashing cursor, and press to enter the selected langu