Major MT750 Instruction Manual
Text of the manual
DIGITAL CLAMP METER
MT750
Barrier
It is a part providing protection against electrical
shock and ensuring the minimum required air and
creep age distances.
1. Specification
Accuracy guaranteed
100% Or less of range
Temperature 23 ± 5°C
Humidity 45 - 75%
ACA (Auto Range)
Range
Accuracy
40A
0.00, 0.03-41.99A
±1.4 %rdg±6dgt
(50/60Hz
Press the trigger to open the Current Sensor and
clamp the one conductor (Dia. 33mm max.) under
test.
NOTE
Measurement accuracy is guaranteed when the
measured object is placed at the center (zone A) of
the Current Sensor. In zone B, 4% of tolerance
should be added to the specified accuracy. In zone
C, measured values should be considered as
reference values
Indicates that this instrument can clamp on
bare conductors when measuring a voltage
corresponding to the applicable measurement
category, which is marked next to this symbol.
AC
DC
Ground (Earth)
This instrument is subject to WEEE Directive
(2002/96/EC). Please contact our dealer near
you at disposal.
Measurement Category
CAT.II
Primary electrical circuits
Major Tech (Pty) Ltd
T9 Industrial Village, Sam Green Road,
Tunney Ext. 9, Elandsfontein,
South Africa
P.O. Box 888, Isando 1600,
South Africa
Telephone: +27 11 872 5500
National Contact Number: 08 61 62 5678
Sales Facsimile: +27 11 822 2806
Admin Facsimile: +27 11 822 1411
e-mail: [email protected]
www.major-tech.com
Major Tech (Pty) Ltd reserves the rig