INSTALLATION / OPERATING INSTRUCTIONS

The TI6000 provides a link between a telephone and the Wireless IQ System. It allows its user to answer and speak on the telephone using a COM6000 COMMUNICATOR. The TI6000 can only be used with Wireless IQ Systems that were originally configured for single-lane operation. Figure 1. TI6000 with cables and telephone jack splitter 1. INSTALLATION Installation of the TI6000 will take approximately 1 hour. Before you begin, coordinate the time of installation with the store owner/manager to minimize disruption of business. The following tools are required:  Phillips (cross-poin ...

Cable Connections and DIP Switch Settings

Connect the base station interface cable and telephone interface cable enclosed with the TI6000 as shown in Figure 3 and described in the following paragraphs. Refer also to the TI6000 wiring diagram, Figure 6. Figure 3. TI6000 interfaces with base station and telephone 1.2.1 Telephone Interface Cable The telephone interface cable is a 100 ft (30.48 meter) cable with a standard RJ11 telephone jack plug at each end.  Plug one end of the telephone interface cable into the receptacle on the TI6000, as shown in Figure 4.  Unplug the telephone from its phone jack and plug the enclosed telephone ja ...

Base Station Interface Cable

There are two types of base station interface cables, as shown in Figure 6 below. Follow the instructions that apply to the type of cable you received with the TI6000. Figure 6. Two types of base station interface cables Type 1 base station interface cable has a RJ45 connector at each end. Type 2 base station interface cable has a RJ45 connector at one end, and five connectors at the other end. 1. Type 1 Interface Cable Installation This cable is used with Wireless IQ base stations that have a J33, RJ45 connector and a S15 DIP switch on their circuit board.  Unplug the base station power adapter from its elect ...

2. Type 2 Interface Cable Installation

This cable is used with Wireless IQ base stations that do not have a J33, RJ45 connector on their circuit board, as seen in Figure 7.  Unplug the base station power adapter from its electrical outlet.  Unscrew and remove the remote antenna cable from the base station.  Open the Wireless IQ Base Station by pressing down on the two release tabs on top of the cabinet and carefully pulling its front panel forward and down. CAUTION: Open the front panel of the base station carefully. Do not let it drop.  Guide the RJ45 end of the cable through the hole in its rear panel, behind the base station and ou ...

1. K1 DIP Switch:

Locate the K1 DIP switch on the Transceiver Circuit Board in the Wireless IQ Base Station, shown in Figure 9.  Set the K1 DIP switch to the following positions: 1 – ON 2 – ON 3 – OFF 4 – OFF  Press the RESET button.  Close the base station and reconnect the remote antenna cable to it. NOTE: If you are going to set the ceiling speaker to beep when the phone rings, wait to close the base station until you have finished #2 below. 2. Optional Ceiling Speaker Ring Setting: Ask the store owner/manager if they want to hear a single beep through the ceiling speaker when the phone rings. If so, locate ...

4. Optional Voice Message Prompt Setting:

The Wireless IQ System can be set up to give a voice message in the headset when the phone is hung up (if either the Red message or Green message is not currently in use). To record a voice message, refer to Figure 12 and follow the instructions below.  Set the desired RED or GREEN MESSAGE switch on the base station to ON.  Press and release the RECORD button on the base station. The RECORD light on the base station should be red for RED MESSAGE or green for GREEN MESSAGE.  Press and hold the “B” button on the COMMUNICATOR® while recording a message (example: “The phone is h ...

The TI6000 allows you to answer incoming phone calls and talk on the telephone

using a COM6000 COMMUNICATOR. To do this, follow the instructions below.  Power ON – Be sure the power switch on the bottom of the TI6000 is in the ON position. The status light on the TI6000 will be on steady red when the power is on and there is no incoming telephone call.  Ringer ON/OFF – If the ringer switch on the TI6000 is in the ON position and your Communicator is in the A2 mode, you will hear two ring tones in your headset for incoming calls. If the ringer switch is in the OFF position, you will not hear any ring tones in your headset ...

IN CASE OF PROBLEMS

Problem Probable Cause Solution No rings heard in headset Ringer switch not on. Set Ringer switch to ON position. In A1 mode instead of A2. Switch to A2 mode. STATUS light on TI6000 not lit. Power not on. Set power switch to ON position. Base station interface cable not plugged in to TI6000. Plug in cable to TI6000. Power wire disconnected from connector in base station. Call HME.* Talking heard in only one direction. Interface cable wires not correctly attached to connectors in base station. Call HME.* Ring tone low. Ring tone level not adjusted correctly. Call HME.* Caller’s voice level low. Level not adjusted correctly. Ca ...

“HME Proprietary and Confidential Information not to be duplicated, disclosed or

distributed except as permitted by an executed Confidentiality and Non-Disclosure Agreement with HME. Copyright HM Electronics, Inc. 2014” ...

Recording Equipment PDF Instructions

DX-TL5000E series
Mitsubishi DX-TL5000E series
06.07.2026 135 pages

1 ENGLISH OTHERS DIGITAL RECORDER INSTALLER’S MANUAL MODEL DX-TL5000E THIS INSTRUCTION MANUAL IS IMPORTANT TO YOU. PLEASE READ IT BEFORE USING YOUR DIGITAL RECORDER. SLD Security & Communications The Old Forge, Ockham Lane, Ockham, Surrey GU23 6PH England P Official user manual for the Mitsubishi DX-TL5000E series Voice Recorder. This documentation provides step-by-step guidance on usage tips, operation, reset instructions, software updates.

Mediasite
Sonic Mediasite
30.07.2026 10 pages

Reference manual for the Sonic Mediasite Recording Equipment. This manual describes setup, usage, and basic operation, installation procedures, operation.

TimeLine
Strymon TimeLine
01.07.2026 26 pages

Device instruction guide for the Strymon TimeLine Music Equipment. It includes troubleshooting procedures and network configuration, hardware setup, functional overview.

Powermax125
Hypertherm Powermax125
22.07.2026 130 pages

Installation and operation manual for the Hypertherm Powermax125 Welding System. This guide offers instructions on startup procedures, usage tips, service contacts.