instructions may result in property damage, serious injury, or death. DANGER ALWAYS disconnect power prior to moving, adjusting, or servicing pump or attached systems. DO NOT use this pump in the presence of spraying or standing water. Failure to do so could result in a fatal electric shock. WARNING: FIRE AND EXPLOSION HAZARD DO NOT use this pump to move flammable or explosive liquids. DO NOT use this pump in explosive or flammable environments. Carbon monoxide hazard. Ensure that pump is mounted ...
PAGE 3 instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. TEMPERATURE RATING (NOT TESTED FOR HOT WATER) • Continuous duty 140˚F • Max inlet temperature 160˚F • Not suitable for contact with steam or gases that exceed 160˚F. GENERAL INFORMATION This pump is designed to automatically remove the condensate water that collects from appliances such as air conditioners and de-humidifiers. The pump has a built-in tank that collects water from the appliance. When water collected reaches sufficie ...
3 CP-22LP CP-22LP-230 Rated Voltage 120 Volts/60Hz 220 Volts/60 Hz Rated Current Draw 1.9 Amps 1.0 Amps Head Height 22 ft. maximum 22 ft. maximum Flow Rate at Zero Head 1.6 GPM 1.0 GPM Product Weight 4.7 lbs. 4.7 lbs. Inlet Height from Base 1.75 in. 1.75 in. Inlet Hole Cover A B ...
PAGE 5 INSTALLATION MOUNTING OPTIONS 1A. PLACE ON FLOOR Determine condensate pump location. 1B. ATTACH TO WALL Attach condensate pump with screws (8” between mounting tabs). OPTION: REVERSE TOP IF NECESSARY Pump top may be rotated 180˚ to allow access to pump outlet or power connection. 1a 1 1 2 1b 8" (20.3 cm) 8" (20.3 cm) Mounting tab ...
Ensure that condensate pump is level. OUTLET CONNECTIONS 3. INSTALL OUTLET TUBE CONNECTION Attach plastic tubing to check valve and secure with hose clamp. Route tubing up and away from condensate pump (avoid compressing or kinking tubing). 2 2 3/8" Clear Vinyl Plastic Tubing 5/8" Hose Clamp Check Valve 3 1 ...
PAGE 7 INSTALLATION (continued) INLET CONNECTIONS 4. INSTALL INLET TUBE CONNECTIONS Install condensate drain tubing into one of the four inlet holes, making sure tubing is straight. If installing to a humidifier, a “P” trap should be used. INLET COVERS 5. INSTALL INLET COVERS Insert inlet covers in remaining condensate pump inlet holes. Inlet Holes Inlet Tubing Inlet Holes 45˚Angle Inlet Tubing 4 To Condensate Pump “P” Trap Condensate Drain Tubing To Humidifier 5 ...
Connect overflow safety switch terminals as shown in wiring diagram. WARNING: RISK OF ELECTRIC SHOCK Ensure that power to appliance and pump is shut off before attempting this step! Failure to follow these warnings will void the warranty and could result in a fatal electric shock. SYSTEM T-STAT Com Run OVERFLOW SWITCH 24V 1A Max Shut-Down Circuit* Shut-Down Circuit* *Overflow Switch is normally closed and opens when a high water level is detected. Connect this circuit in series with the appropriate 24V shut-down circuit for the appliance. A C 6 ...
PAGE 9 INSTALLATION (continued) ELECTRICAL CONNECTION 7. ELECTRICAL CONNECTION WARNING: RISK OF ELECTRIC SHOCK This pump is supplied with a grounding conductor and grounding- type attachment plug.To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle. This pump must be properly connected to power following the National Electric Code (NEC). Failure to follow these warnings will void warranty and could result in a fatal electric shock. A green LED will indicate if power is available. This pump is supplied with a grounding conductor and groun ...
Manually fill the tank with water. An amber LED will indicate pump is operating. 2. TESTING OVERFLOW SWITCH (IF CONNECTED) Manually overfill tank with water. If overflow safety switch is wired correctly, appliance will shut down, condensate pump will pump out water, and a red LED will illuminate. 1 2 1 2 1 2 2 ...
PAGE 11 LED INDICATOR STATUS LED STATUS Green LED Indicates pump has power and is ready Amber LED Indicates pump is running and removing condensate from tank Red LED Indicates pump is in alarm mode and that the system is shutoff/ disabled (if connected) ...
ALWAYS disconnect power before performing maintenance. Pump and deck may be removed from tank by pushing tabs located on tank sides away from deck while lifting on pump cover. Periodically inspect the condensate pump tank to ensure it is free of accumulated dirt or sludge. DO NOT use solvent cleaners. Clean tank with mild soap and warm water only. Check valve may be removed for cleaning or replacement by unscrewing with a 5/8” wrench. Clean inlet and outlet piping. Reassemble system and check for correct operation. ...
PAGE 13 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Unit does not start when full of condensate 1. Power is not supplied to pump. 2. Pump impeller is not turning. 1. Ensure that power is supplied to pump. A green LED indicator on top of pump cover will show that power is supplied and that pump is ready. 2. Clear any blockage in impeller housing. If problem persists, motor is stuck. Return pump to place of purchase if under warranty. Condensate is overflowing from unit 1. Power is not supplied to pump. 2. Pump is in overflow condition. 3. Pump is not level. 4. Outlet flow is blocked. 5. Pump ...
and sold by the Company under the Asurity or Diversitech brand are warranted to be free of defects in workmanship and materials for a period of 36 months from date of sale from the distributor to the contractor. The Company will credit, repair or replace, at its option, any Pump if deemed defective within this time period. All products returned to the Company must include a return authorization issued by the Company. The returned product should be suitably packaged and shipped prepaid from the point of shipment to the point designate ...
PAGE 15 INFORMACIÓN DE SEGURIDAD Lea, comprenda y siga todas las instrucciones de seguridad. Si no respeta las instrucciones, se pueden producir daños a la propiedad, lesiones graves o la muerte. PELIGRO SIEMPRE desconecte la alimentación antes de mover, ajustar o realizar mantenimiento a la bomba o a los sistemas conectados. NO use esta bomba con agua estancada o agua que se rocíe. El incumplimiento de esta medida podría provocar una descarga eléctrica fatal. ADVERTENCIA: PELIGRO DE INCENDIO Y EXPLOSIÓN NO use esta bomba para mover líquidos inflamables o explosivos. NO use esta bomba en ambientes ...
• Funcionamiento continuo a 60 ˚C • Temperatura máxima de entrada de 71,1 ˚C • No es adecuado para contactarse con vapor o con gases que superan los 71,1 ˚C INFORMACIÓN GENERAL Esta bomba de condensación está diseñada para eliminar automáticamente el agua condensada que recolecta de electrodomésticos tales como acondicionadores de aire y deshumidificadores de alta eficiencia. La bomba tiene un tanque integrado que recolecta el agua de los electrodomésticos. Cuando el agua recolectada alcanza un nivel suficiente dentro del tanque de l ...
PAGE 17 CONTENIDO DEL PAQUETE ESPECIFICACIONES PIEZA DESCRIPCIÓN CANTIDAD A Bomba de Condensacion 1 B Cubierta 3 CP-22LP CP-22LP-230 Voltaje calificado 120 voltios/60 Hz 220 voltios/60 Hz Consumo calificado de corriente 1,9 amperios 1,0 amperios Alto de cabezales Máximo de 6,71 m Máximo de 6,71 m Índice de flujo con cabezal cero 6,01 LPM 3,79 LPM Peso de producto 2,13 kg 2,13 kg Alto de entrada a partir de la base 4,45 cm 4,45 cm Cubierta A B ...
1A. COLOQUE EN EL PISO Determine la ubicación de la bomba de condensación 1B. FIJE A LA PARED Fije la bomba de condensación con los tornillos (20,32 cm entre las lengüetas de montaje). OPCIÓN: 2 INVIERTA LA PARTE SUPERIOR SI FUERA NECESARIO La parte superior de la bomba puede girar 180˚ para permitir un fácil acceso a la salida de la bomba o para conectar la alimentación. 1a 1 1 2 1b 8" (20.3 cm) 8" (20.3 cm) Lengüetas colgantes de metal ...
PAGE 19 INSTALACIÓN 2. UNIDAD DE NIVEL Asegúrese de que la bomba de condensación esté nivelada. CONEXIONES DE SALIDA 3. INSTALE LA CONEXIÓN DEL TUBO DE SALIDA Fije el tubo de plástico para verificar la válvula y asegurarlo con la abrazadera para manguera. Guíe la tubería hacia arriba y lejos de la bomba de condensación (Evite comprimir o retorcer la tubería) 2 2 Tubo de vinilo transparente de 3/8” Abrazadera de manguera de 5/8” Válvula de control 3 1 ...
4. INSTALE LAS CONEXIONES DEL TUBO DE ENTRADA Instale la tubería de drenaje de condensación en uno de los cuatro orificios de entrada, asegurándose de que la tubería esté recta. Si instala la bomba a un humidificador de condensación, deberá usar una trampa plástica. CUBIERTA 5. INSTALE LAS CUBIERTAS DE ENTRADA Coloque las cubiertas de entrada en los orificios de entrada restantes de la bomba de condensación. Orificios de entrada Tubería de entrada Angulo de 45˚ 4 Orificios de entrada Tubería de entrada 5 A la bomba de condensación Trampa en P Tubería de drena ...
Water Pump PDF Instructions
OPERATOR’S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 3-11-04 REVISED: 7-15-16 (REV. L) 1” DIAPHRAGM PUMP 1:1 RATIO (METALLIC) READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT. It is the responsibi
Operating Instructions & Parts Manual KTH-S SERIES TRASH PUMP 1 Please read and save these instructions and Engine owner`s manual. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by
1 ALPHA Solar grundfos INSTRUCTIONS net.grundfos.com/qr/i/98092353
C C-Serie C-Series Klaue Claw Edition: 1.0 · 11.2017 · BA 880-80-FU-DE Original Betriebsanleitung C-VLR 1000 VSD Vakuumpumpe Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch Tel. 071 918 60 60, Mail: [email protected]