Read and retain carefully for as long as the product is being used. It

contains vital information on the operation and installation of your Smoke Alarm. The leafet should be regarded as part of the product. If you are just installing the unit, the leaftet must be given to the householder. The leafet is to be given to any subsequent user. Mains Powered Carbon Monoxide Alarm with rechargeable lithium cell back-up Model Ei261ENRC Model Ei261DENRC - with Digit

Ei Electronics Ei261ENRC 1. IMPORTANT INFORMATION

WARNING: The Alarm should be permanently wired to the mains by a qualified electrician in accordance with IEE wiring regulations (BS7671). Install a Carbon Monoxide (CO) Alarm in every room that contains a fuel burning appliance, particularly rooms where people spend a lot of time e.g. bedrooms, kitchens and sitting rooms. In rooms with an appliance, install (preferably) on the ceiling (300mm from walls and between 1m to 3m ho

The CO Alarm is no substitute for keeping

chimneys and flues clear and in good condition, and all of your appliances serviced regularly according to the manufacturer’s instructions. Do not fit alarm until all building work is completed to avoid contamination. 2. CARBON MONOXIDE - THE SILENT KILLER 2.1 WHAT IS CARBON MONOXIDE ? Congratulations on becoming the owner of an Ei Carbon Monoxide Alarm. This will help protect you and your household from the da

Ei Electronics Ei261ENRC Table A: Effects of Carbon Monoxide Poisoning

35 The maximum allowable concentration for continuous exposure in any 8 hour period according to OSHA *. 150 Slight headache after 1.5 hours. 200 Slight headache, fatigue, dizziness, nausea after 2-3 hours. 400 Frontal headaches within 1-2 hours, life threatening after 3 hours, also maximum parts per million in flue gas (on an air free basis) according to US Environmental Protection Agency. 800 Dizziness, nause

Pre-Alarm: When the alarm detects over 50ppm

CO the red light flashes every 2 seconds. This helps locate CO leaks as the unit gives an indication straight away (without this feature the CO level would need to be at 50ppm CO for 90 minutes for the horn to sound). Note the Pre-Alarm signal may be triggered by CO coming for example, from cooking with gas, from car engines or from nearby barbecues. This is usually not a concern unless the Pre-Alarm signal pe

Ei Electronics Ei261ENRC 4. ALARM POSITIONING

4.1 IDEALLY A CARBON MONOXIDE (CO) ALARM SHOULD BE INSTALLED IN: - Every room containing a fuel burning appliance - Remote rooms where occupants spend a considerable amount of time - Every bedroom However if the number of CO Alarms is limited, the following points should be considered when deciding where best to fit the alarm(s) - If there is an appliance in a room where people sleep, place a CO Alarm in this room - Locate a CO Alar

Ei Electronics Ei261ENRC - If the appliance is in a room not normally used (such

as a boiler room) the CO Alarm should be placed just outside the room so that the alarm will be heard more easily 4.2 UNSUITABLE LOCATIONS Do not place the CO Alarm in any of the following areas - In a position, where access to the screwdriver slot to release the CO alarm from its mounting plate, is blocked by an object such as a wall, a fixed item of furniture or skirting board, as this would make re

Figure 2. Location in rooms with sloped ceilings

- 300mm from apex of ceiling - High side of the room CO Alarm about 1 to 2m Figure 3. Location in bedroom & rooms remote from the appliance - Wall mounted - Breathing level (approx. 1 to 2m above floor) 8 300mm 150mm 1 to 3 m 1 to 3 m DEAD AIR DON'T LOCATE HERE CO Alarm Figure 1. Location in room with a fuel burning appliance - 1 to 3m from appliance - Ceiling 300mm (min) from wall - Wall 150m

Warning: The Alarm must be installed by a

competent person. The Alarm is designed to be permanently mounted, using its own built-in terminal block to connect it to the mains wiring. The mounting plate can be screwed directly to the ceiling/wall. Alternatively it can be screwed to a standard junction box (BS 4662 single gang accessory box). The alarm requires a current of 60mA. The Alarm must not be exposed to dripping or splashing. There

The Alarm must be continuously powered 24

hours a day so it is important that it is not on a circuit that can be turned off by a switch. INSTALLATION PROCEDURE 1. Select a location complying with the advice in the previous section. 2. Disconnect the AC mains supply from the circuit that is going to be used to power the Alarm. 3. The house wiring must be connected to the terminal block on the mounting plate as follows: L: Live - connect to the house wi

Ei Electronics Carbon Monoxide Alarm Owners Instructions: