Model Ei 261EN
Model Ei 261DEN
WITH DIGITAL DISPLAY
DIGITAL DISPLAY
Ei261DEN ONLY
Read and retain carefully for as long as the product is being used. It contains vital information on the
operation and installation. The leaflet should be regarded as part of the product.
If you are just installing the unit, the leaflet must be given to the householder. The leaflet is to be given to
any subsequent user.
MAINS POWERED
CARBON MONOXIDE ALARMS
WITH RECHARGEABLE L
READ THIS FIRST
CARBON MONOXIDE - THE SILENT KILLER!
WHERE TO PLACE CARBON MONOXIDE ALARMS
INSTALLING YOUR CARBON MONOXIDE ALARMS
TESTING YOUR CARBON MONOXIDE ALARMS
MAINTAINING CARBON MONOXIDE ALARMS
LIMITATIONS OF CARBON MONOXIDE ALARMS
HOW TO PROTECT YOUR FAMILY
TECHNICAL SPECIFICATIONS
GETTING YOUR CARBON MONOXIDE ALARMS SERVICED
FIVE YEAR GUARANTEE
TROUBLESHOOTING
Page
CONTENTS
B15404-R0-261E
1. READ THIS FIRST
WARNING
The Alarm should be permanently wired to the mains by a qualified electrician in accordance with IEE
wiring regulations (BS7671).
Install the Carbon Monoxide Alarm (CO Alarm) in every room that contains a fuel burning
appliance, particularly rooms where people spend a lot of time e.g. bedrooms, kitchens and sitting
rooms.
In rooms with an appliance install (perferably) on the ceiling (300mm from walls) and between 1m
to 3m horizo
What to do when the alarm sounds:
(1) Open the doors and windows to ventilate the area.
(2) Turn off all fuel appliances where possible and stop them. (The alarm can be silenced
immediately by pushing the test/hush button).
(3) Evacuate the property leaving the doors and windows open.
(4) Get medical help immediately for anyone suffering the effects of Carbon Monoxide poi-
soning (headache, nausea), and advise that Carbon Monoxide poisoning is suspected.
(
Ei Electronics Ei 261DEN The CO Alarm will automatically reset
once the CO has cleared. Pressing the
test/hush button resets the CO Alarm
immediately (below 300ppm CO). If CO
is still present the red light and horn will
turn on again after about 4 minutes.
The CO Alarm is no substitute for keep-
ing chimneys and flues clear and in
good condition, and all of your appli-
ances serviced regularly according to
the manufacturer’s instructions.
Do not fit alarm until all building work
Many are killed each year, and many more suffer ill health from Carbon Monoxide (CO) poisoning. CO is
an invisible, odourless, tasteless and extremely toxic gas. It is produced by appliances and vehicles burn-
ing fuels, such as coal, oil, natural/bottled gas, paraffin, wood, petrol, diesel, charcoal etc. CO is absorbed
by red blood cells in the lungs in preference to oxygen - this results in rapid damage to the heart and
brain from oxygen starvation.
High
Ei Electronics Ei 261DEN A high level of CO for a short period (e.g. 350 ppm CO for 30 minutes) will cause the same symptoms,
a slight headache, as a lower level for a longer time (e.g. 150 ppm for 90 minutes). Table A shows how
exposure to different concentrations of CO generally affects people.
Many cases of reported Carbon Monoxide poisoning indicate that while victims are aware they are not
well, they become so disorientated they are unable to save themselves by either lea
Ei Electronics Ei 261DEN 2.3 What happens when your CO Alarm detects Carbon Monoxide ?
When the Alarm detects potentally dangerous levels of CO, it flashes the red alarm light and then sounds
a loud alarm if the CO persists. The digital display indicates the CO level in parts per million, ppm CO,
(Model Ei261DEN only).
Table B below shows how the CO Alarm reacts to different levels of CO gas and exposure time. At higher
levels of CO the alarm turns on sooner. The rate of flashing
NEVER IGNORE THE ALARM.
Pre-Alarm: When the alarm detects over 50ppm CO the red light flashes every 2 seconds. This helps
locate CO leaks as the unit gives an indication straight away. (Without this feature the CO level would
need to be at 50ppm CO for 90 minutes for an indication to be given). Note the Pre-Alarm signal may be
triggered by CO coming for example, from cooking with gas, from car engines or from nearby barbecues.
This is usually not a concern
Ei Electronics Ei 261DEN When the test button is held for 20 seconds the peak reading resets to zero. (Cover the horn with a cloth
to muffle the loud alarm).
Please note that the memory will also be reset when the unit is removed from the mounting plate.
3. WHERE TO PLACE CO ALARMS
3.1 Ideally a Carbon Monoxide Alarm should be installed in:
- Every room containing a fuel burning appliance, and
- Remote rooms where occupants spend a considerable amount of time
- Every bedroom.
Howe
3.2 Unsuitable Locations
Do not place the CO Alarm in any of the following areas.
(1)
In the immediate vicinity of a cooking appliance (keep it at least 1 metre horizontally from it).
(2)
Outside the building.
(3)
In an enclosed space (e.g. in or below a cupboard).
(4)
In a damp or humid area.
(5)
Directly above a sink or cooker.
(6)
Next to a door, window, air vent or anywhere that it would be affected by draughts.
(7)
Next to an extractor fan.
(8)
Where
Ei Electronics Ei 261DEN 3.3 If locating the CO alarm in a room with a fuel burning appliance (see figure 2)
• If it is mounted on a wall, it should be located at a height greater than the height of any door or window
but still be at least 150mm from the ceiling.
• If it is mounted on the ceiling it should be at least 300mm from any wall or light fitting.
• The CO alarm should be a horizontal distance of between 1m and 3m from the potential CO source.
• If there is a par
Ei Electronics Carbon Monoxide Alarm Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
Ei 220EN |
#65896V: Ei 220EN Carbon Monoxide Alarm Instructions manual |
32 | 0.27 Mb | 625 | 132 | 30-09-2026 |
Ei 225EN |
User Manual: Ei Electronics Ei 225EN (87F8WV, Upd.27-09-2026) |
2 | 0.11 Mb | 607 | 116 | 27-09-2026 |
Ei261ENRC |
Ei261ENRC (Carbon Monoxide Alarm ePDF User Guide, #Q2VPEO) |
20 | 81 | 18 | 01-05-2026 | |
Ei 261DEN |
Ei 261DEN (Carbon Monoxide Alarm ePDF User Guide, #9D533E) |
32 | 0.29 Mb | 286 | 61 | 11-07-2026 |
Ei420 |
PDF Guide (@P22976), Ei Electronics Ei420 Carbon Monoxide Alarm (13-07-2026) |
2 | 0.26 Mb | 1226 | 295 | 13-07-2026 |
Ei 220EN |
PDF User Guide (@777GY3), Ei Electronics Ei 220EN Carbon Monoxide Alarm (10-07-2026) |
32 | 0.23 Mb | 1072 | 172 | 10-07-2026 |