Model Ei 261EN

Model Ei 261DEN WITH DIGITAL DISPLAY DIGITAL DISPLAY Ei261DEN ONLY Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation. The leaflet should be regarded as part of the product. If you are just installing the unit, the leaflet must be given to the householder. The leaflet is to be given to any subsequent user. MAINS POWERED CARBON MONOXIDE ALARMS WITH RECHARGEABLE L

READ THIS FIRST

CARBON MONOXIDE - THE SILENT KILLER! WHERE TO PLACE CARBON MONOXIDE ALARMS INSTALLING YOUR CARBON MONOXIDE ALARMS TESTING YOUR CARBON MONOXIDE ALARMS MAINTAINING CARBON MONOXIDE ALARMS LIMITATIONS OF CARBON MONOXIDE ALARMS HOW TO PROTECT YOUR FAMILY TECHNICAL SPECIFICATIONS GETTING YOUR CARBON MONOXIDE ALARMS SERVICED FIVE YEAR GUARANTEE TROUBLESHOOTING Page CONTENTS B15404-R0-261E

1. READ THIS FIRST

WARNING The Alarm should be permanently wired to the mains by a qualified electrician in accordance with IEE wiring regulations (BS7671). Install the Carbon Monoxide Alarm (CO Alarm) in every room that contains a fuel burning appliance, particularly rooms where people spend a lot of time e.g. bedrooms, kitchens and sitting rooms. In rooms with an appliance install (perferably) on the ceiling (300mm from walls) and between 1m to 3m horizo

What to do when the alarm sounds:

(1) Open the doors and windows to ventilate the area. (2) Turn off all fuel appliances where possible and stop them. (The alarm can be silenced immediately by pushing the test/hush button). (3) Evacuate the property leaving the doors and windows open. (4) Get medical help immediately for anyone suffering the effects of Carbon Monoxide poi- soning (headache, nausea), and advise that Carbon Monoxide poisoning is suspected. (

Ei Electronics Ei 261DEN The CO Alarm will automatically reset

once the CO has cleared. Pressing the test/hush button resets the CO Alarm immediately (below 300ppm CO). If CO is still present the red light and horn will turn on again after about 4 minutes. The CO Alarm is no substitute for keep- ing chimneys and flues clear and in good condition, and all of your appli- ances serviced regularly according to the manufacturer’s instructions. Do not fit alarm until all building work

Many are killed each year, and many more suffer ill health from Carbon Monoxide (CO) poisoning. CO is

an invisible, odourless, tasteless and extremely toxic gas. It is produced by appliances and vehicles burn- ing fuels, such as coal, oil, natural/bottled gas, paraffin, wood, petrol, diesel, charcoal etc. CO is absorbed by red blood cells in the lungs in preference to oxygen - this results in rapid damage to the heart and brain from oxygen starvation. High

Ei Electronics Ei 261DEN A high level of CO for a short period (e.g. 350 ppm CO for 30 minutes) will cause the same symptoms,

a slight headache, as a lower level for a longer time (e.g. 150 ppm for 90 minutes). Table A shows how exposure to different concentrations of CO generally affects people. Many cases of reported Carbon Monoxide poisoning indicate that while victims are aware they are not well, they become so disorientated they are unable to save themselves by either lea

Ei Electronics Ei 261DEN 2.3 What happens when your CO Alarm detects Carbon Monoxide ?

When the Alarm detects potentally dangerous levels of CO, it flashes the red alarm light and then sounds a loud alarm if the CO persists. The digital display indicates the CO level in parts per million, ppm CO, (Model Ei261DEN only). Table B below shows how the CO Alarm reacts to different levels of CO gas and exposure time. At higher levels of CO the alarm turns on sooner. The rate of flashing

NEVER IGNORE THE ALARM.

Pre-Alarm: When the alarm detects over 50ppm CO the red light flashes every 2 seconds. This helps locate CO leaks as the unit gives an indication straight away. (Without this feature the CO level would need to be at 50ppm CO for 90 minutes for an indication to be given). Note the Pre-Alarm signal may be triggered by CO coming for example, from cooking with gas, from car engines or from nearby barbecues. This is usually not a concern

Ei Electronics Ei 261DEN When the test button is held for 20 seconds the peak reading resets to zero. (Cover the horn with a cloth

to muffle the loud alarm). Please note that the memory will also be reset when the unit is removed from the mounting plate. 3. WHERE TO PLACE CO ALARMS 3.1 Ideally a Carbon Monoxide Alarm should be installed in: - Every room containing a fuel burning appliance, and - Remote rooms where occupants spend a considerable amount of time - Every bedroom. Howe

3.2 Unsuitable Locations

Do not place the CO Alarm in any of the following areas. (1) In the immediate vicinity of a cooking appliance (keep it at least 1 metre horizontally from it). (2) Outside the building. (3) In an enclosed space (e.g. in or below a cupboard). (4) In a damp or humid area. (5) Directly above a sink or cooker. (6) Next to a door, window, air vent or anywhere that it would be affected by draughts. (7) Next to an extractor fan. (8) Where

Ei Electronics Ei 261DEN 3.3 If locating the CO alarm in a room with a fuel burning appliance (see figure 2)

• If it is mounted on a wall, it should be located at a height greater than the height of any door or window but still be at least 150mm from the ceiling. • If it is mounted on the ceiling it should be at least 300mm from any wall or light fitting. • The CO alarm should be a horizontal distance of between 1m and 3m from the potential CO source. • If there is a par

Ei Electronics Carbon Monoxide Alarm Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
Ei 220EN

#65896V: Ei 220EN Carbon Monoxide Alarm Instructions manual

32 0.27 Mb 625 132 30-09-2026
Ei 225EN

User Manual: Ei Electronics Ei 225EN (87F8WV, Upd.27-09-2026)

2 0.11 Mb 607 116 27-09-2026
Ei261ENRC

Ei261ENRC (Carbon Monoxide Alarm ePDF User Guide, #Q2VPEO)

20 81 18 01-05-2026
Ei 261DEN

Ei 261DEN (Carbon Monoxide Alarm ePDF User Guide, #9D533E)

32 0.29 Mb 286 61 11-07-2026
Ei420

PDF Guide (@P22976), Ei Electronics Ei420 Carbon Monoxide Alarm (13-07-2026)

2 0.26 Mb 1226 295 13-07-2026
Ei 220EN

PDF User Guide (@777GY3), Ei Electronics Ei 220EN Carbon Monoxide Alarm (10-07-2026)

32 0.23 Mb 1072 172 10-07-2026

Carbon Monoxide Alarm: Similar Manuals