Purkeys DIRECT PLUS Diagnostics Manual
Text of Purkeys DIRECT PLUS Diagnostics Manual
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net
CONTENTS
Cover Assembly ..................................................................................................2
Interior Light Module (optional) .....................................................................2
Connections Inside Nosebox ............................................................................3
Connections Outside Nosebox .............................................
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT PLUS DIAGNOSTIC GUIDE
CONNECTIONS INSIDE NOSEBOX
CONNECTIONS OUTSIDE NOSEBOX
Step 1: Make sure that connections
are tight and inspect wiring for
defects.
BASIC TROUBLESHOOTING
Step 2: Check the 2 amp fuse in
the battery box at the DC/DC
converter.
• If blown , replace
• If good, proceed
WIRE DIAGRAM
NO LIGHTS ON FACE OF THE NOSEBOX
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT PLUS DIAGNOSTIC GUIDE
Step 3: Using a voltmeter, measure
the voltage at the 2-pin terminal
strip on the DC/DC converter
charging plate:
• Place the positive lead on the
liftgate batt+ stud.
• Place the negative lead on the
ground stud.
• If there is a battery voltage
reading, skip to step 5.
• If no voltage is shown, proceed
to step 4.
Step 4: Check the 30 amp circuit
breaker using a volt
BATTERIES NOT BEING CHARGED
Step 1: Connect the tractor 7-way
cable to the trailer and start the
tractor.
• Place the voltmeter positive
lead on the stud labeled
positive input.
• Place the negative lead on the
negative battery post.
• If there is a voltage reading,
proceed to the next step.
• If there is no voltage reading,
skip to step 8.
Step 5: On the front of the trailer,
remove the hardware holding the
cover assembly to the nosebox
base.
�
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT PLUS DIAGNOSTIC GUIDE
Step 2: Next:
• Place the voltmeter positive
lead on the yellow wire stud
labeled ignition.
• Place the negative lead on the
negative battery post.
• Battery voltage should read
approximately 10-13 volts.
Step 3: Unplug the 4-pin connector
from the DC/DC converter.
• Place the voltmeter positive
lead in pin #1 (12v + input).
• Place the negative lead in pin
#3 (gro
Step 5: Next:
• Place the voltmeter negative
lead on the negative battery
post.
• Place the positive lead on the
red junction stud closest to the
converter.
Reading should be 13+ volts.
• If yes, proceed to the next step.
• If no, replace the wiring from
the converter to the converter
plug.
Step 6: Next:
• Place the voltmeter negative
lead on the negative battery
post.
• Place the positive lead on the
circuit breaker post away from
the batter
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT PLUS DIAGNOSTIC GUIDE
Step 7: Next:
• Place the voltmeter negative
lead on the negative battery
post.
• Place the positive lead on the
circuit breaker closest to the
battery post.
Readings should be 13+ volts.
• If yes, the system is working as
designed. Verify that the boost
converter LED is green.
• If no, reset the circuit breaker.
• If the circuit breaker will not
reset, replace it.
Step 9: Next:
• Place the voltmeter positive
lead where the blue wire is
connected.
• Place the negative lead where
the white wire is connected.
Should read tractor voltage.
• If there is a voltage reading,
inspect the wire for defects and
replace if necessary.
• If there is no voltage reading,
check the ground fuse and
replace if blown. If it’s not
blown, replace the cover
assembly.
Step 10: Next:
• Place the voltmeter positive
lead where t
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT PLUS DIAGNOSTIC GUIDE
INTERIOR LIGHTS NOT WORKING (IF INSTALLED)
Step 1: Check for voltage at the
interior light module:
• Place the voltmeter positive
lead on the blue wire.
• Place the negative lead on the
liftgate negative battery post.
• There should be a power source
voltage reading after closing the
interior light switch.
• If there is a voltage reading,
inspect the wiring between
Step 3: Next:
• Place the voltmeter positive
lead on the 30 amp fuse on the
module.
• Place the negative lead on the
gray wire stud on the cover
assembly.
• The voltage should read 0 or a
very low voltage.
• Press the interior light switch.
• The voltage should read 10-14
volts.
• If voltage still reads 0 volts,
check for a blown fuse.
• If the fuse checks good, the
module is deemed defective.
Proceed to the next step to
confirm.
Step 4: T
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT PLUS DIAGNOSTIC GUIDE
LIMITED COMMERCIAL WARRANTY POLICY
MCE Purkeys FE, LLC (hereafter “Purkeys”), warrants each product to be free of defects in
material or workmanship under normal use and service. This warranty is for the benefit of
Original Equipment Manufacturers, Dealers, Warehouse Distributors, Fleets, or other End
Users (hereafter “Customers”) and covers products manufactured by