CONTENTS Cover Assembly ..................................................................................................2 Interior Light Module (optional) .....................................................................2 Connections Inside Nosebox ............................................................................3 Connections Outside Nosebox .............................................
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT PLUS DIAGNOSTIC GUIDE CONNECTIONS INSIDE NOSEBOX CONNECTIONS OUTSIDE NOSEBOX

Step 1: Make sure that connections

are tight and inspect wiring for defects. BASIC TROUBLESHOOTING Step 2: Check the 2 amp fuse in the battery box at the DC/DC converter. • If blown , replace • If good, proceed WIRE DIAGRAM NO LIGHTS ON FACE OF THE NOSEBOX
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT PLUS DIAGNOSTIC GUIDE Step 3: Using a voltmeter, measure the voltage at the 2-pin terminal strip on the DC/DC converter charging plate: • Place the positive lead on the liftgate batt+ stud. • Place the negative lead on the ground stud. • If there is a battery voltage reading, skip to step 5. • If no voltage is shown, proceed to step 4. Step 4: Check the 30 amp circuit breaker using a volt

BATTERIES NOT BEING CHARGED

Step 1: Connect the tractor 7-way cable to the trailer and start the tractor. • Place the voltmeter positive lead on the stud labeled positive input. • Place the negative lead on the negative battery post. • If there is a voltage reading, proceed to the next step. • If there is no voltage reading, skip to step 8. Step 5: On the front of the trailer, remove the hardware holding the cover assembly to the nosebox base. �
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT PLUS DIAGNOSTIC GUIDE Step 2: Next: • Place the voltmeter positive lead on the yellow wire stud labeled ignition. • Place the negative lead on the negative battery post. • Battery voltage should read approximately 10-13 volts. Step 3: Unplug the 4-pin connector from the DC/DC converter. • Place the voltmeter positive lead in pin #1 (12v + input). • Place the negative lead in pin #3 (gro

Step 5: Next:

• Place the voltmeter negative lead on the negative battery post. • Place the positive lead on the red junction stud closest to the converter. Reading should be 13+ volts. • If yes, proceed to the next step. • If no, replace the wiring from the converter to the converter plug. Step 6: Next: • Place the voltmeter negative lead on the negative battery post. • Place the positive lead on the circuit breaker post away from the batter
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT PLUS DIAGNOSTIC GUIDE Step 7: Next: • Place the voltmeter negative lead on the negative battery post. • Place the positive lead on the circuit breaker closest to the battery post. Readings should be 13+ volts. • If yes, the system is working as designed. Verify that the boost converter LED is green. • If no, reset the circuit breaker. • If the circuit breaker will not reset, replace it.

Step 9: Next:

• Place the voltmeter positive lead where the blue wire is connected. • Place the negative lead where the white wire is connected. Should read tractor voltage. • If there is a voltage reading, inspect the wire for defects and replace if necessary. • If there is no voltage reading, check the ground fuse and replace if blown. If it’s not blown, replace the cover assembly. Step 10: Next: • Place the voltmeter positive lead where t
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT PLUS DIAGNOSTIC GUIDE INTERIOR LIGHTS NOT WORKING (IF INSTALLED) Step 1: Check for voltage at the interior light module: • Place the voltmeter positive lead on the blue wire. • Place the negative lead on the liftgate negative battery post. • There should be a power source voltage reading after closing the interior light switch. • If there is a voltage reading, inspect the wiring between

Step 3: Next:

• Place the voltmeter positive lead on the 30 amp fuse on the module. • Place the negative lead on the gray wire stud on the cover assembly. • The voltage should read 0 or a very low voltage. • Press the interior light switch. • The voltage should read 10-14 volts. • If voltage still reads 0 volts, check for a blown fuse. • If the fuse checks good, the module is deemed defective. Proceed to the next step to confirm. Step 4: T
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT PLUS DIAGNOSTIC GUIDE LIMITED COMMERCIAL WARRANTY POLICY MCE Purkeys FE, LLC (hereafter “Purkeys”), warrants each product to be free of defects in material or workmanship under normal use and service. This warranty is for the benefit of Original Equipment Manufacturers, Dealers, Warehouse Distributors, Fleets, or other End Users (hereafter “Customers”) and covers products manufactured by

Purkeys Battery Charger Owners Instructions: