P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net FLEX/MAX DIAGNOSTIC GUIDE
DIRECT MAX
(INCLUDES SEVERE SERVICE CABLES)
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net FLEX/MAX DIAGNOSTIC GUIDE
INTERIOR LIGHT MODULE (OPTIONAL)
CONNECTIONS INSIDE NOSEBOX
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net FLEX/MAX DIAGNOSTIC GUIDE
NO LIGHTS ON FACE OF THE NOSEBOX
Step 1: Confirm all connections are tight and inspect wiring for defects.
Step 2: Connect the tractor to the unit.
Step 3: Start the tractor.
Step 4: Check the 2 amp fuse on the
DC/DC converter in the battery
box:
• If blown, replace.
• If good, proceed.
Step 5: Using a voltmeter, measure
the voltage at the 2-pin terminal
strip on the DC/DC
Step 6: Check the 30 amp circuit
breaker using a voltmeter:
• Place the positive lead on
the circuit breaker stud that
connects to the red junction
stud closest to the DC/DC
converter on the plate.
• Place the negative lead on the
negative post of the battery.
• If there is a battery voltage
reading, proceed to the next
step.
• If no voltage is shown, reset the
circuit breaker.
• If there is still no voltage, check
wiring for defects.
• If no
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net FLEX/MAX DIAGNOSTIC GUIDE
BATTERIES NOT BEING CHARGED
Step 1: Connect the 7-way or dual
pole cable to the trailer and start
the tractor.
• Place the voltmeter positive
lead on the stud labeled as
positive input.
• Place the negative lead on the
negative battery post.
• Read the approximate tractor
voltage.
• If there is a voltage reading,
proceed to the next step.
• If there is no voltage re
Purkeys DIRECT FLEX Step 3: Unplug the 4-pin connector
from the DC/DC converter.
• Place the voltmeter positive
lead in pin #1 (12 v + input).
• Place the negative lead in pin
#3 (ground).
• Read the approximate tractor
voltage.
• If there is a voltage reading,
proceed to the next step.
• If there is no voltage reading,
inspect the wiring and plug and
repair any issues.
Step 4: Next:
• Place the voltmeter negative
lead in pin #3 (ground).
• Place the positive
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net FLEX/MAX DIAGNOSTIC GUIDE
Step 5: Next:
• Place the voltmeter negative
lead on the negative battery
post.
• Place the positive lead on the
red junction stud closest to the
converter.
• The voltage should read 13+
volts.
• If voltage reads 13+, proceed to
the next step.
• If voltage does not read 13+,
replace the wiring from the
converter to the converter plug.
Step 6: Next:
• Place the volt
Step 7: Next:
• Place the voltmeter negative
lead on the negative battery
post.
• Place the positive lead on the
circuit breaker closest to the
battery post.
• The voltage should read 13+
volts.
• If the voltage reads 13+, reset
the circuit breaker.
• If the voltage does not read
13+, the circuit breaker will
not reset. Replace the circuit
breaker.
Step 8: On the front of the trailer,
remove the hardware holding the
cover assembly to the noseb
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net FLEX/MAX DIAGNOSTIC GUIDE
Step 9: Check the dual pole:
• Place the voltmeter positive
lead where the blue wire is
connected.
• Place the negative lead where
the white wire is connected.
• The voltage must be 13.2+ volts
(13.8 volts is optimal).
• If the voltage is 13.2+, inspect
the wire for defects and replace
if necessary.
• If there is no voltage reading,
skip to step 11.
Step 10: Next:
�
Step 11: Next:
• Place the voltmeter positive
lead where the blue wire is
connected.
• Place the negative lead where
the white wire is connected.
• If there is a voltage reading,
inspect the wiring for defects
and replace if necessary.
• If there is no voltage reading,
proceed to the next step.
Step 12: Next:
• Place the voltmeter positive
lead where the blue wire is
connected.
• Place the negative lead where
the white wire is connected.
•
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net FLEX/MAX DIAGNOSTIC GUIDE
INTERIOR LIGHTS NOT WORKING (IF INSTALLED)
The interior lights can be powered by liftgate batteries, dual pole, 7-way,
reefer, etc.
Step 1: Check for voltage at the
interior light module:
• Place the voltmeter positive
lead on the blue wire.
• Place the negative lead on the
white wire.
• There should be a power source
voltage reading after closing the
interior light swit