CONTENTS General Information ........................................................................2 Direct Controller Call-Outs .............................................................3 Wire Diagram and Legend .............................................................4 Diagnostics .....................................................................................6 Excessive Voltage Drop Dia

The Purkeys Direct™ system improves the charging of liftgate

batteries by utilizing a DC/DC Converter to boost the voltage for optimal charging. The boost in voltage overcomes the normal voltage drop caused by the extended distance between the liftgate batteries and the vehicle charging system. Also, in cold temperatures batteries require increased charging voltages to maintain a high state of charge. The DC/DC Converter in the Direct system compensate
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT DIAGNOSTIC GUIDE DIRECT CONTROLLER CALL-OUTS

WIRE DIAGRAM AND LEGEND

Component: A. Liftgate Battery Box B. Liftgate Battery Pack C. P1020-K Liftgate Charging System Plate Assembly D. 30 Amp Circuit Breaker E. DC/DC Converter F. DC/DC Converter Output Stud G. DC/DC Converter Input Stud (+) H. DC/DC Converter Input Stud (-) I. 2 Amp Inline Fuse from Liftgate Batteries J. Direct Controller K. Input Source (Dual/Single Pole, 7-Way, Straight Truck Battery Pack, or Reefer Unit)
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT DIAGNOSTIC GUIDE WIRE COLOR WIRE GAUGE CONNECT FROM CONNECT TO Blue 10 Power In Input Source (+) White 10 Ground Input Source (-) White 8 Ground Liftgate Battery (-) Fused DC/DC Converter Input Stud (-) Yellow 16 DC/DC Converter Ignition DC/DC Converter Ignition Stud Black 8 Direct Controller Power Out to DC/DC converter DC/DC Converter Input (+) Orange 14 Trailer Battery Sense (Controller Power)

If there is excessive voltage drop between the source battery

and the Direct Controller, both Source and Lift Battery LEDs will briefly turn green, indicating that the Direct is trying to charge the batteries. Then both LEDs will toggle orange for a few seconds. This cycle then repeats (see Figure 1 for examples showing this issue). EXCESSIVE VOLTAGE DROP DIAGNOSTICS Figure 1: LEDs briefly turn green, toggle orange, then repeat SERVICE TIP -
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT DIAGNOSTIC GUIDE STATIC DIAGNOSTICS Not connected to a charging source or not charging (at rest) (see Figure 2 for location of Liftgate Battery LED; see Figure 3 for LED status reference, located on right side of Direct Controller). Figure 2 Figure 3 LED STATUS CONDITION ACTION NEEDED REFERENCE Slow Flashing Green Liftgate batteries in good state of charge (more than 12.4 volts). None. Slow Flash

Rapid Flashing Orange LED: Repair ground circuit and/or

replace ground fuse (see Figure 4 for ground fuse location). Figure 4 Figure 5
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT DIAGNOSTIC GUIDE REFERENCE #2 No LED: Open circuit between liftgate battery positive or liftgate battery ground and the Direct Controller. Follow the steps below to diagnose the No LED Status (see Figure 5). 1. Using a voltmeter, measure the voltage between the positive post and the negative post on the liftgate battery (see V1 in Figure 5). If the reading is less than 12.0 V, charge or replace t

from stinger or

aux. None. Slow Flashing Orange Input voltage from the source is less than 12.4 volts. Determine where the problem exists and repair or replace defective portion. Ref #4 Slow Flashing Green Voltage is over 12.4 volts. Start the tractor. Rapid Flashing Orange Open positive fuse on the stinger circuit. Repair the circuit and replace the fuse. Ref #3 No
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT DIAGNOSTIC GUIDE REFERENCE #3 Rapid Flashing Orange LED: Blown fuse on the stinger circuit. Replace the fuse (see Figure 8 for source fuse location). Figure 8 Note: For systems that utilize the aux circuit and a 7-way cord, tractor manufactures have typically used 30 amp fuses on the aux circuit, but some older vehicles may have a 20-25 amp fuse or circuit breaker. Over time, these devices deter
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT DIAGNOSTIC GUIDE REFERENCE #4 Input voltage has not reached 13.8 volt turn-on threshold. Follow the steps below to diagnose. 1. With the stinger cord still plugged in, and the tractor running, use a voltmeter to measure the voltage between the dual pole positive stud and the dual pole negative stud inside the Direct Controller (see V1 in Figure 9 or 10). It should read 13.8 volts or greater. If

SERVICE TIP - Purkeys offers the Liftgate Double Check

tool, which can simplify the diagnosis of liftgate charging system problems caused by excessive voltage drop. For more information on the tool, please call 1-800-219-1269 or visit our website at www.purkeys.net. 7-Way Nosebox Tips: •� Inspect circuits inside the 7-way box for excessive electrical resistance caused by overheating, corrosion, loose/poor connections, or undersized wiring. •� Ch
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT DIAGNOSTIC GUIDE CHARGING DIAGNOSTICS Charging from the source (the source LED is Solid Green). The Lift Battery LED status is as listed in table below (see Figure 12 for location of Liftgate Battery LED; see Figure 13 for LED status reference located, on right side of Direct Controller.) Figure 12 Figure 13 LED STATUS CONDITION ACTION NEEDED REFERENCE Solid Green Charging. None. Slow Flashing G

TESTING THE DC/DC CONVERTER

See Figure 14 to see the LED on the DC/DC converter. A rapid flashing red LED on the converter is normal if the trailer is disconnected from a running truck. It will continue to flash for a short period of time. A rapid flashing red LED is only a fault if the trailer is connected to a running truck. Figure 14 LED STATUS CONDITION ACTION NEEDED REFERENCE Solid Green DC/DC Converter is on. Ensure circuit protection on 30 amp ci
P: 479.419.4800 | F: 479.419.4801 | www.purkeys.net DIRECT DIAGNOSTIC GUIDE REFERENCE #9 Steps to test power to the DC/DC Converter: REFERENCE #10 Steps to testing the DC/DC Converter: 1. Look at the Source LED on the Direct Controller and ensure that it is Solid Green. If no, refer to the Stinger or Aux Diagnostics sections. If yes, measure the voltage at the DC/ DC Converter Input (+) stud and Ground (-) Liftgate Battery (Fused) stud (see V1 on Figure

b. If the voltage at the liftgate batteries is below 14.0 volts,

use a voltmeter to monitor the voltage at the liftgate batteries�for�2–5�minutes�(see�V5�on�Figure�15).�If�the� voltage rises, the DC/DC converter is functioning properly; allow time for the batteries to charge. If the DC/DC converter is not charging, check the wiring and connections to the DC/DC converter. If problem continues, replace the DC/DC converter. c. Using