BFS-STPTL10-RM-xx-10 | Version 1.0

Spare-part set "Operation control system assembly" for Sunny Tripower 8000TL / 10000TL / 12000TL / 15000TL / 17000TL NR-8STP-BFS.BG2 / NR3-8STP-BFS.BG2 / NR-10STP- BFS.BG2 / NR3-10STP-BFS.BG2 / NR-12STP-BFS.BG2 / NR3-12STP-BFS.BG2 / NR-15STP-BFS.BG2 / NR3-15STP-BFS.BG2 / NR-STP-BFS.BG2 / NR3-STP-BFS.BG2 ...

Návod k výměně ....................................................................42

ΕΛΛΗΝΙΚΑ Οδηγίες αντικατάστασης........................................................61 ESPAÑOL Instrucciones para la ...

SMA Solar Technology AG

Replacement Manual BFS-STPTL10-RM-xx-10 3 Legal Provisions The information contained in these documents is the property of SMA Solar Technology AG. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, be it electronic, mechanical, photographic, magnetic or otherwise, without the prior written permission of SMA Solar Technology AG. Internal reproductio ...

Table of Contents

SMA Solar Technology AG Replacement Manual BFS-STPTL10-RM-xx-10 4 Table of Contents 1 Information on this Document................................................. 5 1.1 Validity........................................................................................................................ 5 1.2 Target Group.............................................................................................................. 5 1.3 Content ...

1 Information on this Document

SMA Solar Technology AG Replacement Manual BFS-STPTL10-RM-xx-10 5 1 Information on this Document 1.1 Validity This document is valid for: • NR-8STP-BFS.BG2 • NR3-8STP-BFS.BG2 • NR-10STP-BFS.BG2 • NR3-10STP-BFS.BG2 • NR-12STP-BFS.BG2 • NR3-12STP-BFS.BG2 • NR-15STP-BFS.BG2 • NR3-15STP-BFS.BG2 • NR-STP-BFS.BG2 • NR3-STP-BFS.BG2 1.2 Target Group The tasks described in this document must only be performed by q ...

1 Information on this Document

SMA Solar Technology AG Replacement Manual BFS-STPTL10-RM-xx-10 6 1.4 Symbols in the Document Symbol Explanation Information that is important for a specific topic or goal, but is not safety-rele- vant ☐ Indicates a requirement for meeting a specific goal ☑ Desired result ✖ A problem that might occur Example 1.5 Levels of Warning Messages The following levels of warning messages may occur when handling the product. DAN ...

SMA Solar Technology AG

Replacement Manual BFS-STPTL10-RM-xx-10 7 Typography Use Example [Button] [Key] • Button or key to be selected or pressed • Select [Enter]. # • Placeholder for variable components (e.g., parameter names) • Parameter WCtlHz.Hz# 1.7 Designation in the document Complete designation Designation in this document STP-BFS.BG2 Operation control system assembly, OCS as- sembly, STP-OCS) Operation control assembly (BFS) OCS ...

SMA Solar Technology AG

Replacement Manual BFS-STPTL10-RM-xx-10 8 Any use of the product other than that described in the Intended Use section does not qualify as the intended use. The enclosed documentation is an integral part of this product. Keep the documentation in a convenient, dry place for future reference and observe all instructions contained therein. This document does not replace and is not intended to replace any local, state, provin ...

SMA Solar Technology AG

Replacement Manual BFS-STPTL10-RM-xx-10 9 DANGER Danger to life due to electric shock when touching live system components in case of a ground fault If a ground fault occurs, parts of the system may still be live. Touching live parts and cables results in death or lethal injuries due to electric shock. • Disconnect the inverter from voltage sources and make sure it cannot be reconnected before working on the device. • ...

SMA Solar Technology AG

Replacement Manual BFS-STPTL10-RM-xx-10 10 WARNING Danger to life due to electric shock from destruction of the measuring device due to overvoltage Overvoltage can damage a measuring device and result in voltage being present in the enclosure of the measuring device. Touching the live enclosure of the measuring device results in death or lethal injuries due to electric shock. • Only use measuring devices with a DC input ...

3 Scope of Delivery

SMA Solar Technology AG Replacement Manual BFS-STPTL10-RM-xx-10 11 Observe superordinate standards The repair work on devices and the consideration and application of other standards which correspond to a superordinate standard is the responsibility of the qualified person performing the work. Unauthorized alterations will void guarantee and warranty claims and in most cases terminate the operating license. SMA Solar Technology AG shal ...

4 Overview of the Assembly

SMA Solar Technology AG Replacement Manual BFS-STPTL10-RM-xx-10 12 4 Overview of the Assembly A Figure 1 : Position in the inverter Position Designation A Operation control assembly (BFS) 5 Disconnecting the Inverter from Voltage Sources Prior to performing any work on the inverter, always disconnect it from all voltage sources as described in this section. Always adhere to the prescribed sequence. WARNING Danger to life due to ...

5 Disconnecting the Inverter from Voltage Sources

SMA Solar Technology AG Replacement Manual BFS-STPTL10-RM-xx-10 13 3. If the multifunction relay is used, switch off any supply voltage to the load. 4. DANGER Danger to life due to electric shock and electric arc when disconnecting the ESS in the event of an error If an acoustic signal sounds, the inverter is in error mode. In this case, the removal of the ESS results in death or serious injury due to elec ...

5 Disconnecting the Inverter from Voltage Sources

SMA Solar Technology AG Replacement Manual BFS-STPTL10-RM-xx-10 14 9. Use an appropriate measuring device to ensure that no voltage is present at the AC terminal block between L1 and N, L2 and N, and L3 and N. Insert the test probe into each round opening of the terminal. 10. Use an appropriate measuring device to ensure that no voltage is present at the AC terminal block between L1 and PE, L2 and PE, and ...

5 Disconnecting the Inverter from Voltage Sources

SMA Solar Technology AG Replacement Manual BFS-STPTL10-RM-xx-10 15 15. Release and remove the DC connectors. To do so, insert a flat-blade screwdriver or an angled screwdriver (blade width: 3.5 mm) into one of the side slots and pull the DC connectors out. When doing so, do not lever the DC connectors out, but insert the tool into one of the side slots only to release the locking mechanism, and do not pul ...

5 Disconnecting the Inverter from Voltage Sources

SMA Solar Technology AG Replacement Manual BFS-STPTL10-RM-xx-10 16 • Contact point DC+ and contact point DC‒ • Contact point DC+ and contact point PE ENGLISH ...

6 Removing the BFS Assembly

SMA Solar Technology AG Replacement Manual BFS-STPTL10-RM-xx-10 17 • Contact point DC‒ and contact point grounding conductor 20. NOTICE Damage to the inverter due to electrostatic discharge Touching electronic components can cause damage to or destroy the inverter through electrostatic discharge. • Ground yourself before touching any component. 6 Removing the BFS Assembly 1. Disconnect the inverter from all voltage source ...

7 Installing the BFS assembly

SMA Solar Technology AG Replacement Manual BFS-STPTL10-RM-xx-10 18 2. Unlock the fixing domes of the BFS assembly and carefully pull the BFS assembly forwards from the fixing domes. 7 Installing the BFS assembly 1. NOTICE Risk of damage to the OCS assembly through incorrect insertion The OCS assembly may become damaged through canted insertion or through incorrect pressing on. • Carefully insert the OCS assembly as describe ...

8 Recommissioning the Inverter

SMA Solar Technology AG Replacement Manual BFS-STPTL10-RM-xx-10 19 8 Recommissioning the Inverter 1. Carry out the necessary tests according to the locally applicable laws, standards and directives for the correct recommissioning after power assembly replacement. Take the requirements for component replacements into account (see Section 2.2 "IMPORTANT SAFETY INSTRUCTIONS", page 8). 2. Ensure that the grounding conductor in ...

8 Recommissioning the Inverter

SMA Solar Technology AG Replacement Manual BFS-STPTL10-RM-xx-10 20 10. Tighten all six screws with an Allen key (AF 3) in the order 1 to 6 (torque: 2.0 Nm ± 0.3 Nm). By tightening the screws in the prescribed order, you avoid warping the enclosure lid, which would keep it from sealing correctly. Tip: If the screws fall out of the lower enclosure lid, insert the long screw into the lower middle hole and the five short scr ...