Please read these instructions carefully before use and retain for future reference.

Warning: Do not connect to circuits carrying AC voltage in tone or polarity modes. • The maximum voltage allowed across the leads is 60V DC in tone and polarity modes. Warning: Do not connect to circuits carrying AC or DC voltage in continuity test modes. • Check the test leads, probes and case insulation before using. If you find any breakage or abnormality, or you

On the Tone Generator set the function switch to TONE position.

• The TONE and POWER LEDs will illuminate. • Connect the red test lead to the wire in the cable you wish to trace and connect the black lead to ground. • If the cable is shielded connect the black lead to the shield. • Point the probe tip to the cable and press the TEST button. • The POWER LED on the probe will illuminate. • Adjust the volume/sensitiv

Connect the red test lead to one wire and the black lead to the other wire of the

telephone line being tested. • On the Tone Generator put the function switch to CONTINUITY position. • If the CONTINUITY LED turns green if there is an electrical path between the connection points. • The tester indicates continuity up to 10kΩ. • The LED is brighter on low resistance and less bright on higher resistance. Supplying Talk Power �