Hydrocarbon & Water Dew-Point Analyzer

Transportable Sampling System User’s Manual 97438 Issue 1.3 March 2016

Please fi ll out the form(s) below for each instrument that has been purchased.

Use this information when contacting Michell Instruments for service purposes. Instrument Code Serial Number Invoice Date Location of Instrument Tag No Instrument Code Serial Number Invoice Date Location of Instrument Tag No Instrument Code Serial Number Invoice Date Location of

© 2016 Michell Instruments

This document is the property of Michell Instruments Ltd. and may not be copied or otherwise reproduced, communicated in any way to third parties, nor stored in any Data Processing System without the express written authorization of Michell Instruments Ltd. For Michell Instruments' contact information please go to www.michell.com

Condumax II Transportable

Sampling System User’s Manual iv 97438 Issue 1.3, March 2016 1 INTRODUCTION .......................................................................................................... 1 2 INSTALLATION ............................................................................................................. 4 2.1 Orientation for

Condumax II Transportable

Sampling System User’s Manual Michell Instruments v Safety The manufacturer has designed this equipment to be safe when operated using the procedures detailed in this manual. The user must not use this equipment for any other purpose than that stated. Do not apply values greater than the maximum value stated. This manual contains

Condumax II Transportable

Sampling System User’s Manual vi 97438 Issue 1.3, March 2016 Abbreviations The following abbreviations are used in this manual: AC alternating current atm pressure unit (atmosphere) barg pressure unit (=100 kP or 0.987 atm) (gauge) °C degrees Celsius °F degrees Fahrenheit EU European Union HCdp hydrocarbon dew point Hz Hertz lb

Condumax II Transportable

Sampling System User’s Manual Michell Instruments 1 INTRODUCTION 1 INTRODUCTION The Condumax II Transportable Hydrocarbon Dew-Point Analyzer Sampling System should be used in conjunction with the Condumax II Hydrocarbon Dew-Point Analyzer User’s Manual. The sampling system is in a custom designed, heavy duty, 316 stainless steel

Condumax II Transportable

Sampling System User’s Manual 2 97438 Issue 1.3, March 2016 INTRODUCTION Hydrocarbon dew-point analysis pressure is adjusted by a heated pressure regulator in the range up to 35 barg (500 psig), but it is typical for measurements to be made at the cricondentherm condition of 27 barg (400 psig), where the highest HC dew-point temp

Condumax II Transportable

Sampling System User’s Manual Michell Instruments 3 INTRODUCTION The gas handling components are as follows: Coalescing Filter (F1) Provides protection of the moisture sensor within the Condumax II instrument. Pressure Gauge (PG1) Provides indication of sample gas inlet pressure. Pressure Regulator (PR1) Allows the user to manuall