Ei Electronics Ei2110 Contains vital information on unit operation and installation. Read and retain carefully.

If you are just installing this unit this leaflet MUST be given to the householder. Model: Ei2110 INSTALLER INSTRUCTIONS MULTI-SENSOR FIRE ALARM with Rechargeable Lithium Cell Back-up 230V~ B16350-R0-Ei2100 SERIES-U&C.qxd 18/9/08 3:46 PM Page 1

Ei Electronics Ei2110 1. QUICK GUIDE

1.1 INSTALLATION GUIDE 1.2 ALARM REMOVAL 2. MULTI-SENSOR FIRE ALARM FEATURES 3. HOW MANY ALARMS TO INSTALL 3.1 CATEGORIES OF SYSTEM 3.2 SELECTING ALARM TYPE 3.3 GRADE D, E & F SYSTEMS 4. POSITIONING ALARMS 4.1 LOCATIONS TO AVOID 5. INSTALLATION 5.1 MOUNTING & WIRING ALARMS 5.2 INTERCONNECTING ALARMS 6. ACCESSORIES CONTENTS B16350-R0-Ei2100 SERIES-U&C.qxd 18/9/08 3:46 PM Page 2

Ei Electronics Ei2110 INSTALL IN THE CENTRE OF CEILING AT LEAST 300mm FROM

LIGHT FITTINGS & WALLS ENSURE MAINS POWER IS CORRECTLY CONNECTED TO L & N TERMINALS ON ALL INTERCONNECTED ALARMS - OTHERWISE UNITS WILL BE DAMAGED DO NOT FIT ACTUAL ALARMS UNTIL ALL BUILDING WORK IS COMPLETED TO AVOID CONTAMINATION. AFTER CHECKING OPERATION, COVER ALARMS WITH DUST COVER UNTIL REQUIRED FOR USE DISCONNECT THE ALARMS BEFORE APPLYING HIGH VOLTAGE TO WIRING (FOR INSULATION TESTS) DO NOT ATT

1.1 Installation Guide

GREEN MAINS LIGHT AS THE TAMPER-PROOF CATCH ENGAGES. SWITCH ON MAINS PRESS AND HOLD THE TEST BUTTON ON THE ALARM. CHECK THE ALARM AND ANY INTERCONNECTED UNITS SOUND. DECIDE ON CORRECT POSITION B16350-R0-Ei2100 SERIES-U&C.qxd 18/9/08 3:46 PM Page 4

1.2 Alarm Removal

LOCATE REMOVAL SLOT LOCATE THE ARROW ON THE FRONT FACE OF THE ALARM. THE SLOT IS LOCATED DIRECTLY ABOVE THE ARROW. INSERT SCREWDRIVER INSERT A FLAT-BLADED SCREWDRIVER HORIZONTALLY ABOUT 10mm INTO THE CENTRE OF THE REMOVAL SLOT SLIDE ALARM OFF BASE WITH THE SCREWDRIVER STILL INSERTED, PUSH THE LOWER HALF OF THE ALARM AWAY FROM THE SCREWDRIVER, IN THE DIRECTION OF THE ARROW ON THE COVER HOLD THE LOWER HALF OF THE ALARM AND REMOVE FROM THE

Ei Electronics Ei2110 2. MULTI-SENSOR FIRE ALARM FEATURES

The state of the art EI2110 Multi-Sensor Fire Alarm, with its Heat enhanced Optical Smoke Sensor, has a significantly improved performance as described below. 1. Faster Response to a wider range of fires. The combination of the ultra fast temperature sensing thermistor and the high performance optical sensor within the unit, enhances the fire sensing performance such that the unit detects all the 7 different Test Fires (

4. Replace Alarm Indicator.

If the optical sensor chamber becomes very heavily contaminated, the amber fault light will flash once every 40 seconds to inform the user. Action can then be taken to replace the unit, long before the contamination causes nuisance alarms. 5. Alarm Memory. After a the unit has gone into alarm, the red alarm light will flash twice (1 second apart) every 40 seconds to indicate that the unit has alarmed in the previous 24 hours.

The Multi-Sensor Alarm can be installed for superior performance anywhere the

regulations specify an Optical Smoke Alarm or an Ionisation Smoke Alarm. (The Ei2110 Multi-Sensor Fire Alarm can also be used and interconnected with an Ei166RC Optical Smoke Alarm or an Ei161RC Ionisation Smoke Alarm if necessary). The advice here follows the guidance in British Standard BS 5839-Part 6:2004 in general (for further information see the BS standard itself). The mai

It is therefore recommended that a Fire Risk Assessment is undertaken. The Risk

Assessment would be based on a combination of probabilities: - fire occurring - injury or death to occupant - system operating correctly with a fire - early detection and warning to occupants in the event of a fire. The greater the risks, the more comprehensive and reliable systems are needed. 3.1 Categories of System There are three Categories of LD systems for Life protection

for existing dwellings

MINIMUM PROTECTION LD3 Minimum Protection LD3: Alarms in all hallways, stairways and circulation areas that form part of the escape routes from the dwelling. Multi Storey Dwelling LD3 Living Room Bedroom Bathroom Kitchen Bedroom Shower Garage Multi-Sensor Fire Alarms located: on each storey every 7.5 m of hallways and escape routes within 3m of all bedroom doors (apart from toilets & bathrooms ) Bedroom Bedroom Bedroom Kitche

Ei Electronics Ei2110 Additional Protection LD2: As LD3, but in addition

alarms in all rooms or areas that present a high fire risk to occupants. Heat Alarms located in: (Heat Alarms must be within 5.3m of potential fire sources) each Kitchen Multi-Sensor Fire Alarms or Heat Alarms located in: each Living room (i.e. most frequently used daytime room) Multi-Sensor Fire Alarms located: on each storey every 7.5 m of hallways and escape routes within 3m of all bedroom doors (ap

for dwellings where occupants may be at high risk (e.g. elderly)

OPTIMUM PROTECTION LD1 Optimum Protection LD1: As LD2, but in addition alarms should be located in all rooms and other areas of the dwelling. (apart from toilets or bathrooms) Multi Storey Dwelling LD1 Living Room Bedroom Bathroom Kitchen Bedroom Shower Garage Bedroom Bedroom Bedroom Kitchen / Dining Room Living Room Bathroom Single Storey Dwelling LD1 Heat Alarm do not fit alarm Multi-Se

Ei Electronics Smoke Alarm Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
Ei 3100RF

PDF User Manual (@M9DU43), Ei Electronics Ei 3100RF Smoke Alarm (22-07-2026)

24 0.48 Mb 1293 233 22-07-2026
Ei 225E

Smoke Alarm #RD2744

6 0.14 Mb 274 47 15-04-2026
Ei 261D

User Guide: Ei Electronics Ei 261D (12R6M2, Upd.11-10-2026)

3 0.45 Mb 134 26 11-10-2026
Ei204

Ei204 (Smoke Alarm ePDF Guide, #K41C8F)

6 0.12 Mb 723 145 17-09-2026
Ei181

Smoke Alarm #N5V829

2 0.11 Mb 1013 152 07-09-2026
Ei2110

Ei Electronics Smoke Alarm Installer's instructions (File: PDF, 28-09-2026)

28 0.48 Mb 802 145 28-09-2026
Ei 405

#UB64PO: Ei 405 Smoke Alarm Technical specifications

2 0.11 Mb 175 27 28-05-2026
Ei 100R

PDF User Manual (@8UBT5Y), Ei Electronics Ei 100R Smoke Alarm (18-04-2026)

2 0.11 Mb 1217 256 18-04-2026
Ei141EK

Ei141EK (Smoke Alarm ePDF Guide, #HUH89W)

4 1088 196 26-09-2026
RadioLINK Ei 407

RadioLINK Ei 407 (Smoke Alarm ePDF User Guide, #V42BTS)

2 0.06 Mb 411 74 27-05-2026

Smoke Alarm: Similar Manuals