Extech Instruments MN16A Operation & User’s Manual
Text of Extech Instruments MN16A Operation & User’s Manual
MN16A V1.4 03/12
2
Introduction
Congratulations on your purchase of the Extech MN16A Autoranging Multimeter. This meter measures
AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, Diode Test, and Continuity plus
Thermocouple Temperature. It features a rugged design for heavy duty use This meter is shipped fully
tested and calibrated and, with proper use, will provide years of reliable service.
Safety
This symbol adjacent to another symbol
MN16A V1.4 03/12 3
CAUTIONS
•
Improper use of this meter can cause damage, shock, injury or death. Read and understand
this user manual before operating the meter.
•
Always remove the test leads before replacing the battery or fuses.
•
Inspect the condition of the test leads and the meter itself for any damage before operating the
meter. Repair or replace any damage before use.
•
Use great care when making measurements if the voltages are greate
MN16A V1.4 03/12 4
SAFETY INSTRUCTIONS
This meter has been designed for safe use, but must be operated with caution. The rules listed below
must be carefully followed for safe operation.
1.
NEVER apply voltage or current to the meter that exceeds the specified maximum:
Input Protection Limits
Function
Maximum Input
V DC or V AC
600VDC/AC
mA AC/DC
400mA AC/DC
A AC/DC
10A AC/DC (20A for 30 sec max every 15 min)
Frequency, Resistance, Capacitance,
Diode Te
MN16A V1.4 03/12 5
Controls and Jacks
1. 4,000 count LCD display
2. MODE button
3. HOLD button
4. Function switch
5. COM input jack
6. 10A input jack
7. V, Ω, CAP, Temp, Hz, μA and mA input jack
8. REL button
9. RANGE button
10. Battery compartment (rear)
Symbols and Annunciators
•)))
Continuity
Diode test
Low Battery
n
nano (10
-9) (capacitance)
µ
micro (10
-6) (amps)
m
milli (10
-3) (volts, amps)
A
Amps
k
kilo (10
3) (ohms)
F
Farads (capacitance
MN16A V1.4 03/12 6
Operating Instructions
WARNING: Risk of electrocution. High-voltage circuits, both AC and DC, are very dangerous and
should be measured with great care.
1.
ALWAYS turn the function switch to the OFF position when the meter is not in use.
2.
If “OL” appears in the display during a measurement, the value exceeds the range you have
selected. Change to a higher range.
DC VOLTAGE MEASUREMENTS
CAUTION: Do not measure DC voltages if a m
MN16A V1.4 03/12 7
DC CURRENT MEASUREMENTS
CAUTION: Do not make 20A current measurements for longer than 30 seconds. Exceeding 30
seconds may cause damage to the meter and/or the test leads.
1.
Insert the black test lead banana plug into the negative COM jack.
2.
For current measurements up to 4000µA DC;
Set the function switch to the µA position and insert the red test lead banana
plug into the µA jack.
3.
For current measurements up to 400mA DC;
S
MN16A V1.4 03/12 8
RESISTANCE MEASUREMENTS
WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all
capacitors before taking any resistance measurements. Remove the batteries and unplug the line
cords.
1.
Set the function switch to the Ω position.
2.
Insert the black test lead banana plug into the negative COM jack.
Insert the red test lead banana plug into the positive Ω jack.
3.
Press the MODE button to indicate �
MN16A V1.4 03/12 9
TEMPERATURE MEASUREMENTS
1.
Set the function switch to the ºF or ºC position.
2.
Insert the Temperature Probe into the input jacks, making sure to observe the
correct polarity.
3.
Touch the Temperature Probe head to the part whose temperature you wish to
measure. Keep the probe touching the part under test until the reading
stabilizes (about 30 seconds).
4.
Read the temperature in the display.
Note: The temperature probe is fitted w
MN16A V1.4 03/12 10
AUTORANGING/MANUAL RANGE SELECTION
When the meter is first turned on, it automatically goes into Autoranging. This automatically selects
the best range for the measurements being made and is generally the best mode for most
measurements. For measurement situations requiring that a range be manually selected, perform
the following:
1.
Press the RANGE button. The “Auto” display indicator will turn off.
2.
Press the RANGE key to ste
MN16A V1.4 03/12 11
Maintenance
WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before
removing the back cover or the battery or fuse covers.
WARNING: To avoid electric shock, do not operate your meter until the battery and fuse covers are
in place and fastened securely.
This MultiMeter is designed to provide years of dependable service, if the following care instructions
are performed:
1. KEEP THE METER DRY. If i
MN16A V1.4 03/12 12
Specifications
Function
Range
Resolution
Accuracy
4V
0.001V
40V
0.01V
400V
0.1V
±(1.2% reading + 2 digits)
DC Voltage
(V DC)
600V
1V
±(1.5% reading + 2 digits)
400mV*
0.1mV
±(1.5% reading + 15 digits)
4V
0.001V
±(1.2% reading + 3 digits)
40V
0.01V
400V
0.1V
±(1.5% reading + 3 digits)
600V
1V
±(2.0% reading + 4 digits
AC Voltage
(V AC)
(50 / 60Hz)
*400mV range is not autoranging
400μA
0.1μA
±(1.0% reading + 3 digits)
4000μA
MN16A V1.4 03/12 13
Function
Range
Resolution
Accuracy
5.000Hz
0.001Hz
50.00Hz
0.01Hz
±(1.5% reading + 5 digits)
500.0Hz
0.1Hz
5.000kHz
0.001kHz
50.00kHz
0.01kHz
500.0kHz
0.1kHz
±(1.2% reading + 3 digits)
5.000MHz
0.001MHz
±(1.5% reading + 4 digits)
Frequency
Sensitivity: >0.5V rms min. [ 1MHz; >3V rms > 1MHz
NOTE:
Accuracy is stated at 65
oF to 83
oF (18
oC to 28
oC) and less than 75% RH.
Diode Test
Test current of 0.3mA typical, open circuit voltag
MN16A V1.4 03/12 14
Support lines: U.S. 877-439-8324, Intl. 603-324-7800
Technical support: Option 3; E-mail: [email protected]
Repair & Returns: Option 4; E-mail: [email protected]
Product specifications subject to change without notice
Visit our website: www.extech.com
Extech Instruments Corporation, 9 Townsend West, Nashua, NH 03063
ISO 9001 Certified since 1995
Warranty
EXTECH INSTRUMENTS CORPORATION (a FLIR company) warrants this instrument to be