Sharp R-580D Service Manual
Text of Sharp R-580D Service Manual
In interests of user-safety the oven should be restored to its
original condition and only parts identical to those specified
should be used.
TABLE OF CONTENTS
Page
CAUTION, MICROWAVE RADIATION............................................................................................................. 1
WARNING ...............................................................
GENERAL IMPORTANT INFORMATION
This Manual has been prepared to provide Sharp Corp. Service
engineers with Operation and Service Information.
It is recommended that service engineers carefully study the
entire text of this manual, so they will be qualified to render
satisfactory customer service.
CAUTION
MICROWAVE RADIATION
DO NOT BECOME EXPOSED TO RADIATION FROM
THE MICROWAVE GENERATOR OR OTHER PARTS
CONDUCTING
230 - 240 Volts
50 Hertz
Single phase, 3 wire earthed
Power Consumption
1.55kW
Power Output
1000 watts nominal of RF microwave energy (IEC Test Procedure)
Operating frequency 2450 MHz
Case Dimensions
Width 495 mm
Height 355 mm including foot
Depth 525 mm
Cooking Cavity Dimensions
Width 450 mm
Height 222 mm
Depth 432 mm
Turntable diameter
406 mm
Control Complement
Touch Control System
Clock ( 1:00 - 12:59)
Timer
1. Door handle
2. Touch control panel
3. Digital readout
4. See through door
5. Door seals and sealing surfaces
6. Door safety latches
7. Door hinges
8. Coupling
9. Menu label
10.Oven lamp
11.Waveguide cover
12.Turntable tray
13.Turntable support
14.Ventilation openings
15.Power supply cord
NOTE:
The directed features are disabled after three minutes when the oven is not in use. These features are
automatically enabled when the doo
Closing the door activates all door interlock switches
(1st. latch switch, 2nd. latch switch and stop switch).
IMPORTANT
When the oven door is closed, the monitor switch contacts
(COM-NC) must be open.
When the microwave oven is plugged in a wall outlet, rated
voltage is supplied to the noise filter and the control unit.
Figure O-1 on page 28
1. The display shows "SHARP MICRO-WAVE OVEN".
2. To set any programmes or
An example of how sensor works:
1. Potatoes at room temperature. Vapor is emitted very
slowly.
2. Heat potatoes. Moisture and humidity is emitted rapidly.
You can smell the aroma as it cooks.
3. Sensor detects moisture and humidity and calculates
cooking time and variable power.
Cooking Sequence.
1. Touch each SENSOR COOK or SENSOR INSTANT
REHEAT function pad to operating the sensor cooking.
(See the operation manual for the proper procedure.)
NOT
FUNCTION OF IMPORTANT COMPONENTS
defect in the control unit, the thermal cut-out will open.
Under normal operation, the oven thermal cut-out remains
closed. However, when abnormally high temperatures are
reached within the oven cavity, the oven thermal cut-out
will open at 125˚C, causing the oven to shut down. The
defective thermal cut-out must be replaced with new one.
MAGNETRON THERMAL CUT-OUT
The thermal cut-out located near the magnetron is
WARNING TO SERVICE PERSONNEL
Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following parts
of the high voltage circuit will result in electrocution. High voltage capacitor, Power transformer, Magnetron, High
voltage rectifier assembly, High voltage fuse, High voltage harness.
REMEMBER TO CHECK 3D
1) Disconnect the supply.
2) Door opened, and wedged open.
3) To discharge the high volta
Sharp R-580D CK = Check / RE = Replace
MAGNETRON
POWER TRANSFORMER
H.V. RECTIFIER ASSEMBLY
HIGH VOLTAGE CAPACITOR
1ST. LATCH SWITCH
2ND. LATCH SWITCH
STOP SWITCH
MONITOR SWITCH
MONITOR RESISTOR
THERMAL CUT-OUT 125˚C
FAN MOTOR
TURNTABLE MOTOR
FUSE M10A
TOUCH CONTROL PANEL
KEY UNIT
RELAY (RY-1, RY-2)
FOIL PATERN ON P.W.B.
POWER SUPPLY CORD
SHORTED WIRE HARNESS
OPENED WIRE HARNESS
OVEN LAMP OR SOCKET
WALL OUTLET
MISADJUSTMENT SWITCH
HOME FUSE OR BREAKER
BLOCKED
Sharp R-580D NEVER TOUCH ANY PART IN THE CIRCUIT WITH YOUR HAND OR AN INSULATED TOOL
WHILE THE OVEN IS IN OPERATION.
CARRY OUT 3D CHECK.
Isolate the magnetron from high voltage circuit by removing all leads connected to filament terminal.
To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron
filament terminals, the meter should show a reading of less
Room temperature .................. To = 21˚C
Initial temperature................. T1 = 11°C
Temperature after (42 + 2) = 44 sec. ................................................................ T2 = 21°C
Temperature difference Cold-Warm .............................................................. ∆T1 = 10°C
Measured output power
The equation is “P = 100 x ∆T” ........................................... P = 100 x 10°C = 1000 Watts
Sharp R-580D CARRY OUT 3D CHECKS.
Disconnect the leads from the monitor resistor. Using an ohmmeter and set on a low range. Check
between the terminals of the monitor resistor.
The resistance of monitor resistor is approx. 0.8 ohms.
G
MONITOR RESISTOR TEST
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
D
HIGH VOLTAGE CAPACITOR TEST
CARRY OUT 3D CHECKS.
A. Isolate the high voltage capacitor from the circuit.
B. Continuity check must be carried out with measu
CARRY OUT 3D CHECKS. Disconnect the leads from the motor.
Using an ohmmeter, check the resistance between the two terminals as described in the table below.
Table: Resistance of Motor
Motors
Resistance
Fan motor
Approximately 154 Ω
Turntable motor
Approximately 12 kΩ
If incorrect readings are obtained, replace the motor.
CARRY OUT 4R CHECKS
H
MOTOR WINDING TEST
CARRY OUT 3D CHECKS.
1. If the fus
KEY UNIT TEST
If the display fails to clear when the STOP/CLEAR pad is depressed, first verify the flat ribbon cable
is making good contact, verify that the door sensing switch (stop switch) operates properly; that is
the contacts are closed when the door is closed and open when the door is open. If the door sensing
switch (stop switch) is good, disconnect the flat ribbon cable that connects the k
To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary
on the PWB, this foil pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide
given below for repair.
Problem: POWER ON, indicator does not light up.
CARRY OUT 3D CHECKS.
STEPS
OCCURRENCE
CAUSE OR CORRECTION
The rated AC voltage is not present between
1
Pin No. 1 of the 2-pin connector (A) and the
Check supply vol
(8) If the sensor has not detected the vapour of the food, ERROR will appear and the oven will shut off.
Water load cooking test
Make sure the oven has been plugged in at least five minutes before checking sensor cook operation.
The cabinet should be installed and screws tightened.
(1) Fill approximately 200 milliliters (7.2 oz) of tap water in a 1000 milliliter measuring cup.
(2) Place the container on the center of tray in the oven cavity.
(3)
TOUCH CONTROL PANEL ASSEMBLY
OUTLINE OF TOUCH CONTROL PANEL
The touch control section consists of the following units.
(1) Key Unit
(2) Control Unit
(The Control Unit consists of Power Unit
and CPU Unit).
The principal functions of these units and the signals
communicated among them are explained below.
Key Unit
The key unit is composed of a matrix, signals generated
in the LSI are sent to the key unit through P10-P17.
When a key pad is touched,
Sharp R-580D Signal coming from touch key.
When either G10 line on key matrix is touched, a corresponding signal out of P10 - P17
will be input into ANI0. When no key is touched, the signal is held at "H" level.
2
AN11
IN
Signal similar to AN10.
When either G9 line on key matrix is touched, a corresponding signal will be input into AN11.
3
AVSS
IN
Connected to VC.
4
P10
OUT
Key strobe signal.
Signal applied to touch-key section. A pulse signal is in